{"id":{"repo_id":"bucknell","oai_identifier":"oai:digitalcommons.bucknell.edu:masters_theses-1144"},"canonical_url":"https://search.ndltd.org/etd/bucknell/oai:digitalcommons.bucknell.edu:masters_theses-1144","repository":{"repo_id":"bucknell","name":"Bucknell University","base_url":"https://digitalcommons.bucknell.edu/do/oai/"},"display":{"title":"Measuring Surface Tension of Secondary Atmospheric Aerosols using Atomic Force Microscopy","abstract":"Accurate measurements of particle surface tension are required for models concerning atmospheric aerosol nucleation and activation. However, it is difficult to collect sufficiently large volumes of atmospheric aerosol for use in typical instruments that measure surface tension, such as goniometers or Wilhelmy plates. In this work, a method that measures the surface tension of collected liquid nanoparticles using atomic force microscopy is presented. A film of particles is collected via impaction and probed using nanoneedle tips with the atomic force microscope (AFM). This micro-Wilhelmy method allows for direct measurements of surface tension of small amounts of sample. The micro-Wilhelmy method was verified using liquids whose surface tensions were known. Particles of oxidized Â¿-pinene were then produced, collected, and analyzed using this method. Preliminary results show that oxidized Â¿-pinene particles formed in dry conditions have a surface tension similar to that of pure Â¿-pinene, and particles formed in wet conditions have a surface tension that is significantly higher.","abstract_html":"Accurate measurements of particle surface tension are required for models concerning atmospheric aerosol nucleation and activation. However, it is difficult to collect sufficiently large volumes of atmospheric aerosol for use in typical instruments that measure surface tension, such as goniometers or Wilhelmy plates. In this work, a method that measures the surface tension of collected liquid nanoparticles using atomic force microscopy is presented. A film of particles is collected via impaction and probed using nanoneedle tips with the atomic force microscope (AFM). This micro-Wilhelmy method allows for direct measurements of surface tension of small amounts of sample. The micro-Wilhelmy method was verified using liquids whose surface tensions were known. Particles of oxidized Â¿-pinene were then produced, collected, and analyzed using this method. Preliminary results show that oxidized Â¿-pinene particles formed in dry conditions have a surface tension similar to that of pure Â¿-pinene, and particles formed in wet conditions have a surface tension that is significantly higher.","abstract_has_math":false,"creators":["Hritz, Andrew Donald"],"institution":null,"degree_name":"Master of Science in Chemical Engineering","degree_level":"Masters Thesis","degree_discipline":"Chemical Engineering","degree_department":null,"school":null,"contributors":["Timothy M. Raymond"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T07:08:12Z","subjects":["Atmospheric aerosol","Surface tension","Atomic force","Microscope"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://digitalcommons.bucknell.edu/masters_theses/141","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://digitalcommons.bucknell.edu/masters_theses/141","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://digitalcommons.bucknell.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Adigitalcommons.bucknell.edu%3Amasters_theses-1144","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Timothy M. Raymond"]},{"key":"dc:creator","label":"Author","values":["Hritz, Andrew Donald"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.created","label":"Dc Date Created","values":["2015-05-05T07:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Chemical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Masters Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science in Chemical Engineering"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Atmospheric aerosol","Surface tension","Atomic force","Microscope"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://digitalcommons.bucknell.edu/masters_theses/141"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Accurate measurements of particle surface tension are required for models concerning atmospheric aerosol nucleation and activation. However, it is difficult to collect sufficiently large volumes of atmospheric aerosol for use in typical instruments that measure surface tension, such as goniometers or Wilhelmy plates. In this work, a method that measures the surface tension of collected liquid nanoparticles using atomic force microscopy is presented. A film of particles is collected via impaction and probed using nanoneedle tips with the atomic force microscope (AFM). This micro-Wilhelmy method allows for direct measurements of surface tension of small amounts of sample. The micro-Wilhelmy method was verified using liquids whose surface tensions were known. Particles of oxidized Â¿-pinene were then produced, collected, and analyzed using this method. Preliminary results show that oxidized Â¿-pinene particles formed in dry conditions have a surface tension similar to that of pure Â¿-pinene, and particles formed in wet conditions have a surface tension that is significantly higher."]},{"key":"dc:title","label":"Title","values":["Measuring Surface Tension of Secondary Atmospheric Aerosols using Atomic Force Microscopy"]}]}],"canonical_facts":{"dc:contributor":["Timothy M. Raymond"],"dc:creator":["Hritz, Andrew Donald"],"dc:date.created":["2015-05-05T07:00:00Z"],"dc:description.abstract":["Accurate measurements of particle surface tension are required for models concerning atmospheric aerosol nucleation and activation. However, it is difficult to collect sufficiently large volumes of atmospheric aerosol for use in typical instruments that measure surface tension, such as goniometers or Wilhelmy plates. In this work, a method that measures the surface tension of collected liquid nanoparticles using atomic force microscopy is presented. A film of particles is collected via impaction and probed using nanoneedle tips with the atomic force microscope (AFM). This micro-Wilhelmy method allows for direct measurements of surface tension of small amounts of sample. The micro-Wilhelmy method was verified using liquids whose surface tensions were known. Particles of oxidized Â¿-pinene were then produced, collected, and analyzed using this method. Preliminary results show that oxidized Â¿-pinene particles formed in dry conditions have a surface tension similar to that of pure Â¿-pinene, and particles formed in wet conditions have a surface tension that is significantly higher."],"dc:identifier":["https://digitalcommons.bucknell.edu/masters_theses/141"],"dc:subject":["Atmospheric aerosol","Surface tension","Atomic force","Microscope"],"dc:title":["Measuring Surface Tension of Secondary Atmospheric Aerosols using Atomic Force Microscopy"],"thesis:degree_discipline":["Chemical Engineering"],"thesis:degree_level":["Masters Thesis"],"thesis:degree_name":["Master of Science in Chemical Engineering"]},"updated_at":"2026-11-19T07:08:12Z"}