{"id":{"repo_id":"buffalo","oai_identifier":"oai:ubir.buffalo.edu:10477/86907"},"canonical_url":"https://search.ndltd.org/etd/buffalo/oai:ubir.buffalo.edu:10477/86907","repository":{"repo_id":"buffalo","name":"Buffalo","base_url":"https://ubir.buffalo.edu/oai/request"},"display":{"title":"Bond Strength of Luted Zirconia and Titanium Using Different Resin Cements","abstract":"Background: The success of implant-supported prostheses has been a major milestone in clinical dentistry. However, bonding the zirconia (ZrO2) ceramic component of the two-piece abutments to the titanium (Ti base) by luting agents creates concern regarding the debonding and the longevity of two-piece abutments. The purpose of this study is to evaluate the impact of different resin cements on the bond strength of luted titanium to zirconia and evaluate the impact of shaded and non-shaded zirconia on the bond strength of luted titanium to zirconia. Materials and Methods: Sixty milled titanium (Ti-6Al-4V) cylinders were prepared with a series of abrasive papers (ending in 1200 grits) and polished with diamond slurry. A titanium base was scanned, and the surface area was measured to determine its bonding area. Then thirty non-shaded zirconia and thirty shaded zirconia were milled to cylinders of 8 mm diameter x 5 mm high. The bonding surfaces were abraded with 50 µm Al2O3 particles. Titanium cylinders were randomly separated into three groups of twenty. Each group was assigned to a resin cement. Then, each group was divided into two subgroups, 10 each, according to the zirconia shade. All specimens were subjected to thermal cycling for 1000 cycles, followed by the application of shear force at the bond interface using a universal testing machine (MTS). Two-way ANOVA, Tukey HSD tests, and Levene’s tests were used for statistical analysis of the shear bond strength data (α = .05).Results: Multilink Hybrid provided a significantly higher bond strength compared to Panavia V5 (p = .001). Non-shaded zirconia showed higher bond strength than shaded zirconia, but the differences were not statistically significant. Conclusion: Resin cement selection does have an impact on the bond strength between titanium and zirconia. Also, zirconia shade does not impact the bond strength between titanium and zirconia.","abstract_html":"Background: The success of implant-supported prostheses has been a major milestone in clinical dentistry. However, bonding the zirconia (ZrO2) ceramic component of the two-piece abutments to the titanium (Ti base) by luting agents creates concern regarding the debonding and the longevity of two-piece abutments. The purpose of this study is to evaluate the impact of different resin cements on the bond strength of luted titanium to zirconia and evaluate the impact of shaded and non-shaded zirconia on the bond strength of luted titanium to zirconia. Materials and Methods: Sixty milled titanium (Ti-6Al-4V) cylinders were prepared with a series of abrasive papers (ending in 1200 grits) and polished with diamond slurry. A titanium base was scanned, and the surface area was measured to determine its bonding area. Then thirty non-shaded zirconia and thirty shaded zirconia were milled to cylinders of 8 mm diameter x 5 mm high. The bonding surfaces were abraded with 50 µm Al2O3 particles. Titanium cylinders were randomly separated into three groups of twenty. Each group was assigned to a resin cement. Then, each group was divided into two subgroups, 10 each, according to the zirconia shade. All specimens were subjected to thermal cycling for 1000 cycles, followed by the application of shear force at the bond interface using a universal testing machine (MTS). Two-way ANOVA, Tukey HSD tests, and Levene’s tests were used for statistical analysis of the shear bond strength data (α = .05).Results: Multilink Hybrid provided a significantly higher bond strength compared to Panavia V5 (p = .001). Non-shaded zirconia showed higher bond strength than shaded zirconia, but the differences were not statistically significant. Conclusion: Resin cement selection does have an impact on the bond strength between titanium and zirconia. Also, zirconia shade does not impact the bond strength between titanium and zirconia.","abstract_has_math":false,"creators":["Albabtain, Abdulaziz"],"institution":"State University of New York at Buffalo","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":["Sadid-Zadeh, Ramtin","Oral Sciences"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2020,"date_issued":"2020","date_published":"2020","updated_at":"2026-11-19T07:09:57Z","subjects":["dentistry"],"languages":["eng"],"rights":["Copyright retained by author.","Users of works found in University at Buffalo Institutional Repository (UBIR) are responsible for identifying and contacting the copyright owner for permission to reuse. University at Buffalo Libraries do not manage rights for copyright-protected works and cannot assist with permissions."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10477/86907","outbound_label":"Handle","outbound_source":"dc:identifier","record_url":"https://hdl.handle.net/10477/86907","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Abuffalo%3Aoai%3Aubir.buffalo.edu%3A10477%2F86907","prefix":"oai_dc"},"source_record":{"url":"https://ubir.buffalo.edu/oai/request?verb=GetRecord&metadataPrefix=qdc&identifier=oai%3Aubir.buffalo.edu%3A10477%2F86907","prefix":"qdc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Sadid-Zadeh, Ramtin","Oral Sciences"]},{"key":"dc:creator","label":"Author","values":["Albabtain, Abdulaziz"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2025-02-25T23:24:10Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-02-25T23:24:10Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2025-02-25T23:24:10Z"]},{"key":"dc:date.issued","label":"Date","values":["2020"]},{"key":"dc:publisher","label":"Institution","values":["State University of New York at Buffalo"]},{"key":"dc:type","label":"Dc Type","values":["Text","Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["dentistry"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright retained by author.","Users of works found in University at Buffalo Institutional Repository (UBIR) are responsible for identifying and contacting the copyright owner for permission to reuse. University at Buffalo Libraries do not manage rights for copyright-protected works and cannot assist with permissions."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/10477/86907"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Background: The success of implant-supported prostheses has been a major milestone in clinical dentistry. However, bonding the zirconia (ZrO2) ceramic component of the two-piece abutments to the titanium (Ti base) by luting agents creates concern regarding the debonding and the longevity of two-piece abutments. The purpose of this study is to evaluate the impact of different resin cements on the bond strength of luted titanium to zirconia and evaluate the impact of shaded and non-shaded zirconia on the bond strength of luted titanium to zirconia. Materials and Methods: Sixty milled titanium (Ti-6Al-4V) cylinders were prepared with a series of abrasive papers (ending in 1200 grits) and polished with diamond slurry. A titanium base was scanned, and the surface area was measured to determine its bonding area. Then thirty non-shaded zirconia and thirty shaded zirconia were milled to cylinders of 8 mm diameter x 5 mm high. The bonding surfaces were abraded with 50 µm Al2O3 particles. Titanium cylinders were randomly separated into three groups of twenty. Each group was assigned to a resin cement. Then, each group was divided into two subgroups, 10 each, according to the zirconia shade. All specimens were subjected to thermal cycling for 1000 cycles, followed by the application of shear force at the bond interface using a universal testing machine (MTS). Two-way ANOVA, Tukey HSD tests, and Levene’s tests were used for statistical analysis of the shear bond strength data (α = .05).Results: Multilink Hybrid provided a significantly higher bond strength compared to Panavia V5 (p = .001). Non-shaded zirconia showed higher bond strength than shaded zirconia, but the differences were not statistically significant. Conclusion: Resin cement selection does have an impact on the bond strength between titanium and zirconia. Also, zirconia shade does not impact the bond strength between titanium and zirconia.","**To request an accessible version of the file(s) associated with this item, contact library@buffalo.edu. Please include the item's persistent URL [http://hdl.handle.net/. . .] in your request.**"]},{"key":"dc:title","label":"Title","values":["Bond Strength of Luted Zirconia and Titanium Using Different Resin Cements"]}]}],"canonical_facts":{"dc:contributor":["Sadid-Zadeh, Ramtin","Oral Sciences"],"dc:creator":["Albabtain, Abdulaziz"],"dc:date":["2025-02-25T23:24:10Z"],"dc:date.available":["2025-02-25T23:24:10Z"],"dc:date.created":["2025-02-25T23:24:10Z"],"dc:date.issued":["2020"],"dc:description.abstract":["Background: The success of implant-supported prostheses has been a major milestone in clinical dentistry. However, bonding the zirconia (ZrO2) ceramic component of the two-piece abutments to the titanium (Ti base) by luting agents creates concern regarding the debonding and the longevity of two-piece abutments. The purpose of this study is to evaluate the impact of different resin cements on the bond strength of luted titanium to zirconia and evaluate the impact of shaded and non-shaded zirconia on the bond strength of luted titanium to zirconia. Materials and Methods: Sixty milled titanium (Ti-6Al-4V) cylinders were prepared with a series of abrasive papers (ending in 1200 grits) and polished with diamond slurry. A titanium base was scanned, and the surface area was measured to determine its bonding area. Then thirty non-shaded zirconia and thirty shaded zirconia were milled to cylinders of 8 mm diameter x 5 mm high. The bonding surfaces were abraded with 50 µm Al2O3 particles. Titanium cylinders were randomly separated into three groups of twenty. Each group was assigned to a resin cement. Then, each group was divided into two subgroups, 10 each, according to the zirconia shade. All specimens were subjected to thermal cycling for 1000 cycles, followed by the application of shear force at the bond interface using a universal testing machine (MTS). Two-way ANOVA, Tukey HSD tests, and Levene’s tests were used for statistical analysis of the shear bond strength data (α = .05).Results: Multilink Hybrid provided a significantly higher bond strength compared to Panavia V5 (p = .001). Non-shaded zirconia showed higher bond strength than shaded zirconia, but the differences were not statistically significant. Conclusion: Resin cement selection does have an impact on the bond strength between titanium and zirconia. Also, zirconia shade does not impact the bond strength between titanium and zirconia.","**To request an accessible version of the file(s) associated with this item, contact library@buffalo.edu. Please include the item's persistent URL [http://hdl.handle.net/. . .] in your request.**"],"dc:identifier":["http://hdl.handle.net/10477/86907"],"dc:language":["eng"],"dc:publisher":["State University of New York at Buffalo"],"dc:rights":["Copyright retained by author.","Users of works found in University at Buffalo Institutional Repository (UBIR) are responsible for identifying and contacting the copyright owner for permission to reuse. University at Buffalo Libraries do not manage rights for copyright-protected works and cannot assist with permissions."],"dc:subject":["dentistry"],"dc:title":["Bond Strength of Luted Zirconia and Titanium Using Different Resin Cements"],"dc:type":["Text","Thesis"]},"updated_at":"2026-11-19T07:09:57Z"}