{"id":{"repo_id":"buffalo","oai_identifier":"oai:ubir.buffalo.edu:10477/87940"},"canonical_url":"https://search.ndltd.org/etd/buffalo/oai:ubir.buffalo.edu:10477/87940","repository":{"repo_id":"buffalo","name":"Buffalo","base_url":"https://ubir.buffalo.edu/oai/request"},"display":{"title":"Effects of Optical See-Through Head-Mounted Display Use for Simulated Laparoscopic Surgery","abstract":"Laparoscopic surgery is a commonly used minimally invasive surgery (MIS) technique. In laparoscopic surgery, the surgeons operate surgical tools through small incisions while looking at the surgical field on a monitor. However, because of the complexity of the operating room (OR), such as the need to accommodate the surgical staff, the monitor cannot always be placed at the optimal position for the surgeons. This often leads to surgeons developing physical fatigue and can have a negative effect on their performance. With the ability to always display the image in front of the user’s eye but not completely blocking the real environment, optical see-though (OST) head-mounted displays (HMDs) have become a potential solution. However, the effects of extended usage of OST HMDs on surgical task performance, situation awareness, and user ergonomics are not clear. This dissertation investigated the influence of using OST HMDs as a replacement of the conventional monitors for an extended duration, as required for laparoscopic surgery, on surgical task performance, situation awareness, visual fatigue, physical load, and perceived workload. We first conducted a literature review of the usage of HMDs for minimally invasive surgical tasks, both in the OR and simulation settings, to investigate the effects of using HMDs that have been reported in the literature. Then we developed the experiment scenario including two displays (surgical field and patient vitals) in three different combinations (both displays in the HMD, mixed displays (one on HMD and one on a conventional monitor), and both on conventional monitors). An experiment was conducted to compare the task performance, situation awareness, visual fatigue, physical discomfort, and perceived workload in the three different display settings. From this study, it was shown that even though the OST HMD resulted in higher physical discomfort and lower self-perceived performance rating, the surgical task performance, and situation awareness were not worse, and in some conditions even better than conventional monitors. The main obstacle of using OST HMDs to replace the conventional monitors in laparoscopic surgery would be the weight of the HMDs and the head discomfort caused by wearing them for a long time.","abstract_html":"Laparoscopic surgery is a commonly used minimally invasive surgery (MIS) technique. In laparoscopic surgery, the surgeons operate surgical tools through small incisions while looking at the surgical field on a monitor. However, because of the complexity of the operating room (OR), such as the need to accommodate the surgical staff, the monitor cannot always be placed at the optimal position for the surgeons. This often leads to surgeons developing physical fatigue and can have a negative effect on their performance. With the ability to always display the image in front of the user’s eye but not completely blocking the real environment, optical see-though (OST) head-mounted displays (HMDs) have become a potential solution. However, the effects of extended usage of OST HMDs on surgical task performance, situation awareness, and user ergonomics are not clear. This dissertation investigated the influence of using OST HMDs as a replacement of the conventional monitors for an extended duration, as required for laparoscopic surgery, on surgical task performance, situation awareness, visual fatigue, physical load, and perceived workload. We first conducted a literature review of the usage of HMDs for minimally invasive surgical tasks, both in the OR and simulation settings, to investigate the effects of using HMDs that have been reported in the literature. Then we developed the experiment scenario including two displays (surgical field and patient vitals) in three different combinations (both displays in the HMD, mixed displays (one on HMD and one on a conventional monitor), and both on conventional monitors). An experiment was conducted to compare the task performance, situation awareness, visual fatigue, physical discomfort, and perceived workload in the three different display settings. From this study, it was shown that even though the OST HMD resulted in higher physical discomfort and lower self-perceived performance rating, the surgical task performance, and situation awareness were not worse, and in some conditions even better than conventional monitors. The main obstacle of using OST HMDs to replace the conventional monitors in laparoscopic surgery would be the weight of the HMDs and the head discomfort caused by wearing them for a long time.","abstract_has_math":false,"creators":["Fu, Yaoyu; 0000-0002-5890-4745"],"institution":"State University of New York at Buffalo","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":["Cavuoto, Lora","Industrial and Systems Engineering"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2021,"date_issued":"2021","date_published":"2021","updated_at":"2026-11-19T07:10:09Z","subjects":["industrial engineering"],"languages":["eng"],"rights":["Copyright retained by author.","Users of works found in University at Buffalo Institutional Repository (UBIR) are responsible for identifying and contacting the copyright owner for permission to reuse. University at Buffalo Libraries do not manage rights for copyright-protected works and cannot assist with permissions."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10477/87940","outbound_label":"Handle","outbound_source":"dc:identifier","record_url":"https://hdl.handle.net/10477/87940","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Abuffalo%3Aoai%3Aubir.buffalo.edu%3A10477%2F87940","prefix":"oai_dc"},"source_record":{"url":"https://ubir.buffalo.edu/oai/request?verb=GetRecord&metadataPrefix=qdc&identifier=oai%3Aubir.buffalo.edu%3A10477%2F87940","prefix":"qdc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Cavuoto, Lora","Industrial and Systems Engineering"]},{"key":"dc:creator","label":"Author","values":["Fu, Yaoyu; 0000-0002-5890-4745"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2025-06-25T21:41:03Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-06-25T21:41:03Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2025-06-25T21:41:03Z"]},{"key":"dc:date.issued","label":"Date","values":["2021"]},{"key":"dc:publisher","label":"Institution","values":["State University of New York at Buffalo"]},{"key":"dc:type","label":"Dc Type","values":["Text","Dissertation"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["industrial engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright retained by author.","Users of works found in University at Buffalo Institutional Repository (UBIR) are responsible for identifying and contacting the copyright owner for permission to reuse. University at Buffalo Libraries do not manage rights for copyright-protected works and cannot assist with permissions."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/10477/87940"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Laparoscopic surgery is a commonly used minimally invasive surgery (MIS) technique. In laparoscopic surgery, the surgeons operate surgical tools through small incisions while looking at the surgical field on a monitor. However, because of the complexity of the operating room (OR), such as the need to accommodate the surgical staff, the monitor cannot always be placed at the optimal position for the surgeons. This often leads to surgeons developing physical fatigue and can have a negative effect on their performance. With the ability to always display the image in front of the user’s eye but not completely blocking the real environment, optical see-though (OST) head-mounted displays (HMDs) have become a potential solution. However, the effects of extended usage of OST HMDs on surgical task performance, situation awareness, and user ergonomics are not clear. This dissertation investigated the influence of using OST HMDs as a replacement of the conventional monitors for an extended duration, as required for laparoscopic surgery, on surgical task performance, situation awareness, visual fatigue, physical load, and perceived workload. We first conducted a literature review of the usage of HMDs for minimally invasive surgical tasks, both in the OR and simulation settings, to investigate the effects of using HMDs that have been reported in the literature. Then we developed the experiment scenario including two displays (surgical field and patient vitals) in three different combinations (both displays in the HMD, mixed displays (one on HMD and one on a conventional monitor), and both on conventional monitors). An experiment was conducted to compare the task performance, situation awareness, visual fatigue, physical discomfort, and perceived workload in the three different display settings. From this study, it was shown that even though the OST HMD resulted in higher physical discomfort and lower self-perceived performance rating, the surgical task performance, and situation awareness were not worse, and in some conditions even better than conventional monitors. The main obstacle of using OST HMDs to replace the conventional monitors in laparoscopic surgery would be the weight of the HMDs and the head discomfort caused by wearing them for a long time.","**To request an accessible version of the file(s) associated with this item, contact library@buffalo.edu. Please include the item's persistent URL [http://hdl.handle.net/. . .] in your request.**"]},{"key":"dc:title","label":"Title","values":["Effects of Optical See-Through Head-Mounted Display Use for Simulated Laparoscopic Surgery"]}]}],"canonical_facts":{"dc:contributor":["Cavuoto, Lora","Industrial and Systems Engineering"],"dc:creator":["Fu, Yaoyu; 0000-0002-5890-4745"],"dc:date":["2025-06-25T21:41:03Z"],"dc:date.available":["2025-06-25T21:41:03Z"],"dc:date.created":["2025-06-25T21:41:03Z"],"dc:date.issued":["2021"],"dc:description.abstract":["Laparoscopic surgery is a commonly used minimally invasive surgery (MIS) technique. In laparoscopic surgery, the surgeons operate surgical tools through small incisions while looking at the surgical field on a monitor. However, because of the complexity of the operating room (OR), such as the need to accommodate the surgical staff, the monitor cannot always be placed at the optimal position for the surgeons. This often leads to surgeons developing physical fatigue and can have a negative effect on their performance. With the ability to always display the image in front of the user’s eye but not completely blocking the real environment, optical see-though (OST) head-mounted displays (HMDs) have become a potential solution. However, the effects of extended usage of OST HMDs on surgical task performance, situation awareness, and user ergonomics are not clear. This dissertation investigated the influence of using OST HMDs as a replacement of the conventional monitors for an extended duration, as required for laparoscopic surgery, on surgical task performance, situation awareness, visual fatigue, physical load, and perceived workload. We first conducted a literature review of the usage of HMDs for minimally invasive surgical tasks, both in the OR and simulation settings, to investigate the effects of using HMDs that have been reported in the literature. Then we developed the experiment scenario including two displays (surgical field and patient vitals) in three different combinations (both displays in the HMD, mixed displays (one on HMD and one on a conventional monitor), and both on conventional monitors). An experiment was conducted to compare the task performance, situation awareness, visual fatigue, physical discomfort, and perceived workload in the three different display settings. From this study, it was shown that even though the OST HMD resulted in higher physical discomfort and lower self-perceived performance rating, the surgical task performance, and situation awareness were not worse, and in some conditions even better than conventional monitors. The main obstacle of using OST HMDs to replace the conventional monitors in laparoscopic surgery would be the weight of the HMDs and the head discomfort caused by wearing them for a long time.","**To request an accessible version of the file(s) associated with this item, contact library@buffalo.edu. Please include the item's persistent URL [http://hdl.handle.net/. . .] in your request.**"],"dc:identifier":["http://hdl.handle.net/10477/87940"],"dc:language":["eng"],"dc:publisher":["State University of New York at Buffalo"],"dc:rights":["Copyright retained by author.","Users of works found in University at Buffalo Institutional Repository (UBIR) are responsible for identifying and contacting the copyright owner for permission to reuse. University at Buffalo Libraries do not manage rights for copyright-protected works and cannot assist with permissions."],"dc:subject":["industrial engineering"],"dc:title":["Effects of Optical See-Through Head-Mounted Display Use for Simulated Laparoscopic Surgery"],"dc:type":["Text","Dissertation"]},"updated_at":"2026-11-19T07:10:09Z"}