{"id":{"repo_id":"buffalo","oai_identifier":"oai:ubir.buffalo.edu:10477/88167"},"canonical_url":"https://search.ndltd.org/etd/buffalo/oai:ubir.buffalo.edu:10477/88167","repository":{"repo_id":"buffalo","name":"Buffalo","base_url":"https://ubir.buffalo.edu/oai/request"},"display":{"title":"CMDM Resonators and Dielectric Coated Dipole Antenna for Ultra-High Field MR Imaging: Field Efficiency and Safety Evaluations","abstract":"Common mode and Differential mode (CMDM) Resonator is a promising RF technique for ultra-high field MR imaging applications, offering compact planar structure and quadrature operation capability. This work used the microstrip transmission line method (MTL) to form the CMDM coils. Using this method at Ultra-high field MRI RF coil design has become advantageous by improving imaging quality by reducing radiation loss, increasing MR sensitivity, and improving field distributions. Common and Differential modes exist in a single microstrip line which yields two different current distributions. Due to this feature, the CMDM resonator can generate circularly polarized magnetic fields, making CMDM an excellent candidate for designing multichannel quadrature RF coil arrays if a working decoupling method can be identified. We investigate the possibilities of the capacitive decoupling method to decouple the quadrature CMDM resonators and compare the decoupling performance with and without a capacitive decoupling network in this study. Further, we designed and investigated an 8-channel coil array for human knee imaging at 7T using capacitively decoupled common modes (CM) of bent microstrip. The CMDM resonators can be an excellent building block in designing ultrahigh field multichannel coil arrays if a working decoupling method is applied. Later, the second part of this paper consists of a Half-wave dipole antenna. The design is based on coating the whole conductor (half-wave dipole antenna) lengths with a high dielectric material of a certain thickness. Dipole antenna as a resonant device is advocated for ultrahigh field MR imaging applications due to its simple structure and high-frequency capability. Two significant issues encountered in dipole antennas used in MRI are difficulties in frequency/size control and high electric field leading to increased specific absorption rate (SAR). The dipole length primarily determines the resonant frequency of a dipole antenna. Therefore, it is difficult to tune small half-wave dipole antennas less than 50 cm at 300MHz. The half-wavelength resonator feature of the dipole antenna yields amplified electric field strength along the dipole conductor, particularly at the two ends of the dipole. This could elevate SAR, resulting in increased safety hazards during imaging acquisition. We suggest and examine a new method in this paper, using high permittivity dielectric material coated on the dipole conductor to address the frequency/size and safety issues. Our design provides a solution to these problems. It can tune smaller half-wave dipole antennas at 300MHz without meandering the dipole conductors and suppress electric fields, thus reducing SAR in imaging samples.","abstract_html":"Common mode and Differential mode (CMDM) Resonator is a promising RF technique for ultra-high field MR imaging applications, offering compact planar structure and quadrature operation capability. This work used the microstrip transmission line method (MTL) to form the CMDM coils. Using this method at Ultra-high field MRI RF coil design has become advantageous by improving imaging quality by reducing radiation loss, increasing MR sensitivity, and improving field distributions. Common and Differential modes exist in a single microstrip line which yields two different current distributions. Due to this feature, the CMDM resonator can generate circularly polarized magnetic fields, making CMDM an excellent candidate for designing multichannel quadrature RF coil arrays if a working decoupling method can be identified. We investigate the possibilities of the capacitive decoupling method to decouple the quadrature CMDM resonators and compare the decoupling performance with and without a capacitive decoupling network in this study. Further, we designed and investigated an 8-channel coil array for human knee imaging at 7T using capacitively decoupled common modes (CM) of bent microstrip. The CMDM resonators can be an excellent building block in designing ultrahigh field multichannel coil arrays if a working decoupling method is applied. Later, the second part of this paper consists of a Half-wave dipole antenna. The design is based on coating the whole conductor (half-wave dipole antenna) lengths with a high dielectric material of a certain thickness. Dipole antenna as a resonant device is advocated for ultrahigh field MR imaging applications due to its simple structure and high-frequency capability. Two significant issues encountered in dipole antennas used in MRI are difficulties in frequency/size control and high electric field leading to increased specific absorption rate (SAR). The dipole length primarily determines the resonant frequency of a dipole antenna. Therefore, it is difficult to tune small half-wave dipole antennas less than 50 cm at 300MHz. The half-wavelength resonator feature of the dipole antenna yields amplified electric field strength along the dipole conductor, particularly at the two ends of the dipole. This could elevate SAR, resulting in increased safety hazards during imaging acquisition. We suggest and examine a new method in this paper, using high permittivity dielectric material coated on the dipole conductor to address the frequency/size and safety issues. Our design provides a solution to these problems. It can tune smaller half-wave dipole antennas at 300MHz without meandering the dipole conductors and suppress electric fields, thus reducing SAR in imaging samples.","abstract_has_math":false,"creators":["Gawande, Divya"],"institution":"State University of New York at Buffalo","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":["Zhang, Xiaoliang","Biomedical Engineering"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2022,"date_issued":"2022","date_published":"2022","updated_at":"2026-11-19T07:10:13Z","subjects":["biomedical engineering"],"languages":["eng"],"rights":["Copyright retained by author. Users of works found in University at Buffalo Institutional Repository (UBIR) are responsible for identifying and contacting the copyright owner for permission to reuse. University at Buffalo Libraries do not manage rights for copyright-protected works and cannot assist with permissions."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/10477/88167","outbound_label":"Handle","outbound_source":"dc:identifier","record_url":"http://hdl.handle.net/10477/88167","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://ubir.buffalo.edu/oai/request?verb=GetRecord&metadataPrefix=qdc&identifier=oai%3Aubir.buffalo.edu%3A10477%2F88167","prefix":"qdc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Zhang, Xiaoliang","Biomedical Engineering"]},{"key":"dc:creator","label":"Author","values":["Gawande, Divya"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2025-07-24T01:41:58Z","2022","2022-01-13 23:33:36"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-07-24T01:41:58Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2025-07-24T01:41:58Z"]},{"key":"dc:date.issued","label":"Date","values":["2022"]},{"key":"dc:publisher","label":"Institution","values":["State University of New York at Buffalo"]},{"key":"dc:type","label":"Dc Type","values":["Text","Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["biomedical engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright retained by author. Users of works found in University at Buffalo Institutional Repository (UBIR) are responsible for identifying and contacting the copyright owner for permission to reuse. University at Buffalo Libraries do not manage rights for copyright-protected works and cannot assist with permissions."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/10477/88167"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["M.S.","Common mode and Differential mode (CMDM) Resonator is a promising RF technique for ultra-high field MR imaging applications, offering compact planar structure and quadrature operation capability. This work used the microstrip transmission line method (MTL) to form the CMDM coils. Using this method at Ultra-high field MRI RF coil design has become advantageous by improving imaging quality by reducing radiation loss, increasing MR sensitivity, and improving field distributions. Common and Differential modes exist in a single microstrip line which yields two different current distributions. Due to this feature, the CMDM resonator can generate circularly polarized magnetic fields, making CMDM an excellent candidate for designing multichannel quadrature RF coil arrays if a working decoupling method can be identified. We investigate the possibilities of the capacitive decoupling method to decouple the quadrature CMDM resonators and compare the decoupling performance with and without a capacitive decoupling network in this study. Further, we designed and investigated an 8-channel coil array for human knee imaging at 7T using capacitively decoupled common modes (CM) of bent microstrip. The CMDM resonators can be an excellent building block in designing ultrahigh field multichannel coil arrays if a working decoupling method is applied. Later, the second part of this paper consists of a Half-wave dipole antenna. The design is based on coating the whole conductor (half-wave dipole antenna) lengths with a high dielectric material of a certain thickness. Dipole antenna as a resonant device is advocated for ultrahigh field MR imaging applications due to its simple structure and high-frequency capability. Two significant issues encountered in dipole antennas used in MRI are difficulties in frequency/size control and high electric field leading to increased specific absorption rate (SAR). The dipole length primarily determines the resonant frequency of a dipole antenna. Therefore, it is difficult to tune small half-wave dipole antennas less than 50 cm at 300MHz. The half-wavelength resonator feature of the dipole antenna yields amplified electric field strength along the dipole conductor, particularly at the two ends of the dipole. This could elevate SAR, resulting in increased safety hazards during imaging acquisition. We suggest and examine a new method in this paper, using high permittivity dielectric material coated on the dipole conductor to address the frequency/size and safety issues. Our design provides a solution to these problems. It can tune smaller half-wave dipole antennas at 300MHz without meandering the dipole conductors and suppress electric fields, thus reducing SAR in imaging samples.","**To request an accessible version of the file(s) associated with this item, contact library@buffalo.edu. Please include the item's persistent URL [http://hdl.handle.net/. . .] in your request.**"]},{"key":"dc:description.abstract","label":"Abstract","values":["Common mode and Differential mode (CMDM) Resonator is a promising RF technique for ultra-high field MR imaging applications, offering compact planar structure and quadrature operation capability. This work used the microstrip transmission line method (MTL) to form the CMDM coils. Using this method at Ultra-high field MRI RF coil design has become advantageous by improving imaging quality by reducing radiation loss, increasing MR sensitivity, and improving field distributions. Common and Differential modes exist in a single microstrip line which yields two different current distributions. Due to this feature, the CMDM resonator can generate circularly polarized magnetic fields, making CMDM an excellent candidate for designing multichannel quadrature RF coil arrays if a working decoupling method can be identified. We investigate the possibilities of the capacitive decoupling method to decouple the quadrature CMDM resonators and compare the decoupling performance with and without a capacitive decoupling network in this study. Further, we designed and investigated an 8-channel coil array for human knee imaging at 7T using capacitively decoupled common modes (CM) of bent microstrip. The CMDM resonators can be an excellent building block in designing ultrahigh field multichannel coil arrays if a working decoupling method is applied. Later, the second part of this paper consists of a Half-wave dipole antenna. The design is based on coating the whole conductor (half-wave dipole antenna) lengths with a high dielectric material of a certain thickness. Dipole antenna as a resonant device is advocated for ultrahigh field MR imaging applications due to its simple structure and high-frequency capability. Two significant issues encountered in dipole antennas used in MRI are difficulties in frequency/size control and high electric field leading to increased specific absorption rate (SAR). The dipole length primarily determines the resonant frequency of a dipole antenna. Therefore, it is difficult to tune small half-wave dipole antennas less than 50 cm at 300MHz. The half-wavelength resonator feature of the dipole antenna yields amplified electric field strength along the dipole conductor, particularly at the two ends of the dipole. This could elevate SAR, resulting in increased safety hazards during imaging acquisition. We suggest and examine a new method in this paper, using high permittivity dielectric material coated on the dipole conductor to address the frequency/size and safety issues. Our design provides a solution to these problems. It can tune smaller half-wave dipole antennas at 300MHz without meandering the dipole conductors and suppress electric fields, thus reducing SAR in imaging samples.","**To request an accessible version of the file(s) associated with this item, contact library@buffalo.edu. Please include the item's persistent URL [http://hdl.handle.net/. . .] in your request.**"]},{"key":"dc:format","label":"Dc Format","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["CMDM Resonators and Dielectric Coated Dipole Antenna for Ultra-High Field MR Imaging: Field Efficiency and Safety Evaluations"]}]}],"canonical_facts":{"dc:contributor":["Zhang, Xiaoliang","Biomedical Engineering"],"dc:creator":["Gawande, Divya"],"dc:date":["2025-07-24T01:41:58Z","2022","2022-01-13 23:33:36"],"dc:date.available":["2025-07-24T01:41:58Z"],"dc:date.created":["2025-07-24T01:41:58Z"],"dc:date.issued":["2022"],"dc:description":["M.S.","Common mode and Differential mode (CMDM) Resonator is a promising RF technique for ultra-high field MR imaging applications, offering compact planar structure and quadrature operation capability. This work used the microstrip transmission line method (MTL) to form the CMDM coils. Using this method at Ultra-high field MRI RF coil design has become advantageous by improving imaging quality by reducing radiation loss, increasing MR sensitivity, and improving field distributions. Common and Differential modes exist in a single microstrip line which yields two different current distributions. Due to this feature, the CMDM resonator can generate circularly polarized magnetic fields, making CMDM an excellent candidate for designing multichannel quadrature RF coil arrays if a working decoupling method can be identified. We investigate the possibilities of the capacitive decoupling method to decouple the quadrature CMDM resonators and compare the decoupling performance with and without a capacitive decoupling network in this study. Further, we designed and investigated an 8-channel coil array for human knee imaging at 7T using capacitively decoupled common modes (CM) of bent microstrip. The CMDM resonators can be an excellent building block in designing ultrahigh field multichannel coil arrays if a working decoupling method is applied. Later, the second part of this paper consists of a Half-wave dipole antenna. The design is based on coating the whole conductor (half-wave dipole antenna) lengths with a high dielectric material of a certain thickness. Dipole antenna as a resonant device is advocated for ultrahigh field MR imaging applications due to its simple structure and high-frequency capability. Two significant issues encountered in dipole antennas used in MRI are difficulties in frequency/size control and high electric field leading to increased specific absorption rate (SAR). The dipole length primarily determines the resonant frequency of a dipole antenna. Therefore, it is difficult to tune small half-wave dipole antennas less than 50 cm at 300MHz. The half-wavelength resonator feature of the dipole antenna yields amplified electric field strength along the dipole conductor, particularly at the two ends of the dipole. This could elevate SAR, resulting in increased safety hazards during imaging acquisition. We suggest and examine a new method in this paper, using high permittivity dielectric material coated on the dipole conductor to address the frequency/size and safety issues. Our design provides a solution to these problems. It can tune smaller half-wave dipole antennas at 300MHz without meandering the dipole conductors and suppress electric fields, thus reducing SAR in imaging samples.","**To request an accessible version of the file(s) associated with this item, contact library@buffalo.edu. Please include the item's persistent URL [http://hdl.handle.net/. . .] in your request.**"],"dc:description.abstract":["Common mode and Differential mode (CMDM) Resonator is a promising RF technique for ultra-high field MR imaging applications, offering compact planar structure and quadrature operation capability. This work used the microstrip transmission line method (MTL) to form the CMDM coils. Using this method at Ultra-high field MRI RF coil design has become advantageous by improving imaging quality by reducing radiation loss, increasing MR sensitivity, and improving field distributions. Common and Differential modes exist in a single microstrip line which yields two different current distributions. Due to this feature, the CMDM resonator can generate circularly polarized magnetic fields, making CMDM an excellent candidate for designing multichannel quadrature RF coil arrays if a working decoupling method can be identified. We investigate the possibilities of the capacitive decoupling method to decouple the quadrature CMDM resonators and compare the decoupling performance with and without a capacitive decoupling network in this study. Further, we designed and investigated an 8-channel coil array for human knee imaging at 7T using capacitively decoupled common modes (CM) of bent microstrip. The CMDM resonators can be an excellent building block in designing ultrahigh field multichannel coil arrays if a working decoupling method is applied. Later, the second part of this paper consists of a Half-wave dipole antenna. The design is based on coating the whole conductor (half-wave dipole antenna) lengths with a high dielectric material of a certain thickness. Dipole antenna as a resonant device is advocated for ultrahigh field MR imaging applications due to its simple structure and high-frequency capability. Two significant issues encountered in dipole antennas used in MRI are difficulties in frequency/size control and high electric field leading to increased specific absorption rate (SAR). The dipole length primarily determines the resonant frequency of a dipole antenna. Therefore, it is difficult to tune small half-wave dipole antennas less than 50 cm at 300MHz. The half-wavelength resonator feature of the dipole antenna yields amplified electric field strength along the dipole conductor, particularly at the two ends of the dipole. This could elevate SAR, resulting in increased safety hazards during imaging acquisition. We suggest and examine a new method in this paper, using high permittivity dielectric material coated on the dipole conductor to address the frequency/size and safety issues. Our design provides a solution to these problems. It can tune smaller half-wave dipole antennas at 300MHz without meandering the dipole conductors and suppress electric fields, thus reducing SAR in imaging samples.","**To request an accessible version of the file(s) associated with this item, contact library@buffalo.edu. Please include the item's persistent URL [http://hdl.handle.net/. . .] in your request.**"],"dc:format":["application/pdf"],"dc:identifier":["http://hdl.handle.net/10477/88167"],"dc:language":["eng"],"dc:publisher":["State University of New York at Buffalo"],"dc:rights":["Copyright retained by author. Users of works found in University at Buffalo Institutional Repository (UBIR) are responsible for identifying and contacting the copyright owner for permission to reuse. University at Buffalo Libraries do not manage rights for copyright-protected works and cannot assist with permissions."],"dc:subject":["biomedical engineering"],"dc:title":["CMDM Resonators and Dielectric Coated Dipole Antenna for Ultra-High Field MR Imaging: Field Efficiency and Safety Evaluations"],"dc:type":["Text","Thesis"]},"updated_at":"2026-11-19T07:10:13Z"}