{"id":{"repo_id":"buffalo","oai_identifier":"oai:ubir.buffalo.edu:10477/88415"},"canonical_url":"https://search.ndltd.org/etd/buffalo/oai:ubir.buffalo.edu:10477/88415","repository":{"repo_id":"buffalo","name":"Buffalo","base_url":"https://ubir.buffalo.edu/oai/request"},"display":{"title":"Simulation of Respiratory Particles in a Restaurant Dining Area Using Computational Fluid Dynamics","abstract":"Social gathering places like restaurants are one of the biggest contributors to the spread of airborne diseases like the COVID-19 virus. The goal of this study was to understand how virus spreads in an air-conditioned restaurant dining area. Computational fluid dynamics was used to model the restaurant and respiratory particles. Three configurations of supply and return vents were studied in a scenario where a COVID-19 carrier sneezes and releases virus laden saliva droplets into the air. The distribution of the droplets airborne, deposited on adjacent tables, floor and exhausted out of the room through the return vents was compared to determine the vent configuration that poses the least risk of infection for the patrons. Taking the best vent configuration, the effect of air changes per hour (ACH) was studied by comparing the percentages of airborne and exhausted droplets for three values of ACH. Lastly, two vent configurations were compared in a scenario with multiple diners talking within the span of two minutes. Saliva droplets released by each person was tracked and the percentages of airborne and exhausted droplets were compared. A staggered supply vent configuration was found to be most effective in removing airborne particles. Increasing ACH decreased the percentage of airborne particles. In activities like sneezing, which have a higher percentage of larger droplets, very few particles were deposited on tables kept at a 2 m distance from each other. Respiratory particles released by activities like talking have a smaller diameter and hence, have a higher percentage being exhausted than larger sneeze droplets.","abstract_html":"Social gathering places like restaurants are one of the biggest contributors to the spread of airborne diseases like the COVID-19 virus. The goal of this study was to understand how virus spreads in an air-conditioned restaurant dining area. Computational fluid dynamics was used to model the restaurant and respiratory particles. Three configurations of supply and return vents were studied in a scenario where a COVID-19 carrier sneezes and releases virus laden saliva droplets into the air. The distribution of the droplets airborne, deposited on adjacent tables, floor and exhausted out of the room through the return vents was compared to determine the vent configuration that poses the least risk of infection for the patrons. Taking the best vent configuration, the effect of air changes per hour (ACH) was studied by comparing the percentages of airborne and exhausted droplets for three values of ACH. Lastly, two vent configurations were compared in a scenario with multiple diners talking within the span of two minutes. Saliva droplets released by each person was tracked and the percentages of airborne and exhausted droplets were compared. A staggered supply vent configuration was found to be most effective in removing airborne particles. Increasing ACH decreased the percentage of airborne particles. In activities like sneezing, which have a higher percentage of larger droplets, very few particles were deposited on tables kept at a 2 m distance from each other. Respiratory particles released by activities like talking have a smaller diameter and hence, have a higher percentage being exhausted than larger sneeze droplets.","abstract_has_math":false,"creators":["Bhagwat, Sanika"],"institution":"State University of New York at Buffalo","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":["Battaglia, Francine","Mechanical and Aerospace Engineering"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2022,"date_issued":"2022","date_published":"2022","updated_at":"2026-11-19T07:10:22Z","subjects":["mechanical engineering"],"languages":["eng"],"rights":["Copyright retained by author. Users of works found in University at Buffalo Institutional Repository (UBIR) are responsible for identifying and contacting the copyright owner for permission to reuse. University at Buffalo Libraries do not manage rights for copyright-protected works and cannot assist with permissions."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10477/88415","outbound_label":"Handle","outbound_source":"dc:identifier","record_url":"https://hdl.handle.net/10477/88415","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Abuffalo%3Aoai%3Aubir.buffalo.edu%3A10477%2F88415","prefix":"oai_dc"},"source_record":{"url":"https://ubir.buffalo.edu/oai/request?verb=GetRecord&metadataPrefix=qdc&identifier=oai%3Aubir.buffalo.edu%3A10477%2F88415","prefix":"qdc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Battaglia, Francine","Mechanical and Aerospace Engineering"]},{"key":"dc:creator","label":"Author","values":["Bhagwat, Sanika"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2025-08-25T14:44:24Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-08-25T14:44:24Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2025-08-25T14:44:24Z"]},{"key":"dc:date.issued","label":"Date","values":["2022"]},{"key":"dc:publisher","label":"Institution","values":["State University of New York at Buffalo"]},{"key":"dc:type","label":"Dc Type","values":["Text","Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["mechanical engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright retained by author. Users of works found in University at Buffalo Institutional Repository (UBIR) are responsible for identifying and contacting the copyright owner for permission to reuse. University at Buffalo Libraries do not manage rights for copyright-protected works and cannot assist with permissions."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/10477/88415"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Social gathering places like restaurants are one of the biggest contributors to the spread of airborne diseases like the COVID-19 virus. The goal of this study was to understand how virus spreads in an air-conditioned restaurant dining area. Computational fluid dynamics was used to model the restaurant and respiratory particles. Three configurations of supply and return vents were studied in a scenario where a COVID-19 carrier sneezes and releases virus laden saliva droplets into the air. The distribution of the droplets airborne, deposited on adjacent tables, floor and exhausted out of the room through the return vents was compared to determine the vent configuration that poses the least risk of infection for the patrons. Taking the best vent configuration, the effect of air changes per hour (ACH) was studied by comparing the percentages of airborne and exhausted droplets for three values of ACH. Lastly, two vent configurations were compared in a scenario with multiple diners talking within the span of two minutes. Saliva droplets released by each person was tracked and the percentages of airborne and exhausted droplets were compared. A staggered supply vent configuration was found to be most effective in removing airborne particles. Increasing ACH decreased the percentage of airborne particles. In activities like sneezing, which have a higher percentage of larger droplets, very few particles were deposited on tables kept at a 2 m distance from each other. Respiratory particles released by activities like talking have a smaller diameter and hence, have a higher percentage being exhausted than larger sneeze droplets.","**To request an accessible version of the file(s) associated with this item, contact library@buffalo.edu. Please include the item's persistent URL [http://hdl.handle.net/. . .] in your request.**"]},{"key":"dc:title","label":"Title","values":["Simulation of Respiratory Particles in a Restaurant Dining Area Using Computational Fluid Dynamics"]}]}],"canonical_facts":{"dc:contributor":["Battaglia, Francine","Mechanical and Aerospace Engineering"],"dc:creator":["Bhagwat, Sanika"],"dc:date":["2025-08-25T14:44:24Z"],"dc:date.available":["2025-08-25T14:44:24Z"],"dc:date.created":["2025-08-25T14:44:24Z"],"dc:date.issued":["2022"],"dc:description.abstract":["Social gathering places like restaurants are one of the biggest contributors to the spread of airborne diseases like the COVID-19 virus. The goal of this study was to understand how virus spreads in an air-conditioned restaurant dining area. Computational fluid dynamics was used to model the restaurant and respiratory particles. Three configurations of supply and return vents were studied in a scenario where a COVID-19 carrier sneezes and releases virus laden saliva droplets into the air. The distribution of the droplets airborne, deposited on adjacent tables, floor and exhausted out of the room through the return vents was compared to determine the vent configuration that poses the least risk of infection for the patrons. Taking the best vent configuration, the effect of air changes per hour (ACH) was studied by comparing the percentages of airborne and exhausted droplets for three values of ACH. Lastly, two vent configurations were compared in a scenario with multiple diners talking within the span of two minutes. Saliva droplets released by each person was tracked and the percentages of airborne and exhausted droplets were compared. A staggered supply vent configuration was found to be most effective in removing airborne particles. Increasing ACH decreased the percentage of airborne particles. In activities like sneezing, which have a higher percentage of larger droplets, very few particles were deposited on tables kept at a 2 m distance from each other. Respiratory particles released by activities like talking have a smaller diameter and hence, have a higher percentage being exhausted than larger sneeze droplets.","**To request an accessible version of the file(s) associated with this item, contact library@buffalo.edu. Please include the item's persistent URL [http://hdl.handle.net/. . .] in your request.**"],"dc:identifier":["http://hdl.handle.net/10477/88415"],"dc:language":["eng"],"dc:publisher":["State University of New York at Buffalo"],"dc:rights":["Copyright retained by author. Users of works found in University at Buffalo Institutional Repository (UBIR) are responsible for identifying and contacting the copyright owner for permission to reuse. University at Buffalo Libraries do not manage rights for copyright-protected works and cannot assist with permissions."],"dc:subject":["mechanical engineering"],"dc:title":["Simulation of Respiratory Particles in a Restaurant Dining Area Using Computational Fluid Dynamics"],"dc:type":["Text","Thesis"]},"updated_at":"2026-11-19T07:10:22Z"}