{"id":{"repo_id":"buffalo","oai_identifier":"oai:ubir.buffalo.edu:10477/88959"},"canonical_url":"https://search.ndltd.org/etd/buffalo/oai:ubir.buffalo.edu:10477/88959","repository":{"repo_id":"buffalo","name":"Buffalo","base_url":"https://ubir.buffalo.edu/oai/request"},"display":{"title":"Evaluation of Surface and Mechanical Properties of Ceramic-Reinforced PEEK as a Denture Base Material","abstract":"Introduction: The aim of this in vitro study was to evaluate the feasibility of ceramic-reinforced PEEK as a new denture base material by analyzing its microbial adhesion and flexural strength and comparing these properties to currently used denture base materials. Materials and Methods: Three test groups were included in the study. Ceramic-reinforced PEEK, milled PMMA and conventional PMMA. The study was conducted in three phases. First, flexural strength was tested using the 3-point bend test after preparing specimens according to ISO standard for flexural strength testing. The ultimate flexural strength for each specimen was calculated using the following formula: Flexural Strength (MPa)=3PL/(2bd^2 ). Flexural modulus was calculated for each specimen using the following equation: Flexural Modulus (MPa)=(PL^3)/(4Ybd^3 ). Surface properties were then tested using SEM analysis, EDX analysis, and contact angle analysis. To test surface properties, round samples measuring 12 x 2mm were fabricated. Lastly, Candida albicans adhesion was evaluated using the same samples fabricated for surface properties evaluation. Candida albicans adhesion was evaluated by means of CFU counting. Results: Ceramic-reinforced PEEK showed significantly higher flexural strength (p<0.001) than milled and conventional PMMA. Flexural modulus was significantly higher in the BioHPP group (p<0.001). PEEK samples showed greater critical surface tension and surface free energy compared to both PMMA samples. There was no significant difference in CFU counts among the groups. Conclusion: Based on the results of this study, ceramic-reinforced PEEK shows significantly higher flexural strength and flexural modulus compared to both PMMA groups. Surface characterization demonstrates that PEEK samples had a higher polar force as a percentage of surface free energy. There was no statistically significant difference in the mean CFUs/cm2 between polished and unpolished samples.","abstract_html":"Introduction: The aim of this in vitro study was to evaluate the feasibility of ceramic-reinforced PEEK as a new denture base material by analyzing its microbial adhesion and flexural strength and comparing these properties to currently used denture base materials. Materials and Methods: Three test groups were included in the study. Ceramic-reinforced PEEK, milled PMMA and conventional PMMA. The study was conducted in three phases. First, flexural strength was tested using the 3-point bend test after preparing specimens according to ISO standard for flexural strength testing. The ultimate flexural strength for each specimen was calculated using the following formula: Flexural Strength (MPa)=3PL/(2bd^2 ). Flexural modulus was calculated for each specimen using the following equation: Flexural Modulus (MPa)=(PL^3)/(4Ybd^3 ). Surface properties were then tested using SEM analysis, EDX analysis, and contact angle analysis. To test surface properties, round samples measuring 12 x 2mm were fabricated. Lastly, Candida albicans adhesion was evaluated using the same samples fabricated for surface properties evaluation. Candida albicans adhesion was evaluated by means of CFU counting. Results: Ceramic-reinforced PEEK showed significantly higher flexural strength (p&lt;0.001) than milled and conventional PMMA. Flexural modulus was significantly higher in the BioHPP group (p&lt;0.001). PEEK samples showed greater critical surface tension and surface free energy compared to both PMMA samples. There was no significant difference in CFU counts among the groups. Conclusion: Based on the results of this study, ceramic-reinforced PEEK shows significantly higher flexural strength and flexural modulus compared to both PMMA groups. Surface characterization demonstrates that PEEK samples had a higher polar force as a percentage of surface free energy. There was no statistically significant difference in the mean CFUs/cm2 between polished and unpolished samples.","abstract_has_math":false,"creators":["Almogbel, Lolowh"],"institution":"State University of New York at Buffalo","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":["Li, Rui","Biomaterials"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2023,"date_issued":"2023","date_published":"2023","updated_at":"2026-11-19T07:10:30Z","subjects":["dentistry"],"languages":["eng"],"rights":["Copyright retained by author. Users of works found in University at Buffalo Institutional Repository (UBIR) are responsible for identifying and contacting the copyright owner for permission to reuse. University at Buffalo Libraries do not manage rights for copyright-protected works and cannot assist with permissions."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10477/88959","outbound_label":"Handle","outbound_source":"dc:identifier","record_url":"https://hdl.handle.net/10477/88959","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Abuffalo%3Aoai%3Aubir.buffalo.edu%3A10477%2F88959","prefix":"oai_dc"},"source_record":{"url":"https://ubir.buffalo.edu/oai/request?verb=GetRecord&metadataPrefix=qdc&identifier=oai%3Aubir.buffalo.edu%3A10477%2F88959","prefix":"qdc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Li, Rui","Biomaterials"]},{"key":"dc:creator","label":"Author","values":["Almogbel, Lolowh"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2025-10-08T23:29:54Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-10-08T23:29:54Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2025-10-08T23:29:54Z"]},{"key":"dc:date.issued","label":"Date","values":["2023"]},{"key":"dc:publisher","label":"Institution","values":["State University of New York at Buffalo"]},{"key":"dc:type","label":"Dc Type","values":["Text","Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["dentistry"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright retained by author. Users of works found in University at Buffalo Institutional Repository (UBIR) are responsible for identifying and contacting the copyright owner for permission to reuse. University at Buffalo Libraries do not manage rights for copyright-protected works and cannot assist with permissions."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/10477/88959"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Introduction: The aim of this in vitro study was to evaluate the feasibility of ceramic-reinforced PEEK as a new denture base material by analyzing its microbial adhesion and flexural strength and comparing these properties to currently used denture base materials. Materials and Methods: Three test groups were included in the study. Ceramic-reinforced PEEK, milled PMMA and conventional PMMA. The study was conducted in three phases. First, flexural strength was tested using the 3-point bend test after preparing specimens according to ISO standard for flexural strength testing. The ultimate flexural strength for each specimen was calculated using the following formula: Flexural Strength (MPa)=3PL/(2bd^2 ). Flexural modulus was calculated for each specimen using the following equation: Flexural Modulus (MPa)=(PL^3)/(4Ybd^3 ). Surface properties were then tested using SEM analysis, EDX analysis, and contact angle analysis. To test surface properties, round samples measuring 12 x 2mm were fabricated. Lastly, Candida albicans adhesion was evaluated using the same samples fabricated for surface properties evaluation. Candida albicans adhesion was evaluated by means of CFU counting. Results: Ceramic-reinforced PEEK showed significantly higher flexural strength (p<0.001) than milled and conventional PMMA. Flexural modulus was significantly higher in the BioHPP group (p<0.001). PEEK samples showed greater critical surface tension and surface free energy compared to both PMMA samples. There was no significant difference in CFU counts among the groups. Conclusion: Based on the results of this study, ceramic-reinforced PEEK shows significantly higher flexural strength and flexural modulus compared to both PMMA groups. Surface characterization demonstrates that PEEK samples had a higher polar force as a percentage of surface free energy. There was no statistically significant difference in the mean CFUs/cm2 between polished and unpolished samples.","**To request an accessible version of the file(s) associated with this item, contact library@buffalo.edu. Please include the item's persistent URL [http://hdl.handle.net/. . .] in your request.**"]},{"key":"dc:title","label":"Title","values":["Evaluation of Surface and Mechanical Properties of Ceramic-Reinforced PEEK as a Denture Base Material"]}]}],"canonical_facts":{"dc:contributor":["Li, Rui","Biomaterials"],"dc:creator":["Almogbel, Lolowh"],"dc:date":["2025-10-08T23:29:54Z"],"dc:date.available":["2025-10-08T23:29:54Z"],"dc:date.created":["2025-10-08T23:29:54Z"],"dc:date.issued":["2023"],"dc:description.abstract":["Introduction: The aim of this in vitro study was to evaluate the feasibility of ceramic-reinforced PEEK as a new denture base material by analyzing its microbial adhesion and flexural strength and comparing these properties to currently used denture base materials. Materials and Methods: Three test groups were included in the study. Ceramic-reinforced PEEK, milled PMMA and conventional PMMA. The study was conducted in three phases. First, flexural strength was tested using the 3-point bend test after preparing specimens according to ISO standard for flexural strength testing. The ultimate flexural strength for each specimen was calculated using the following formula: Flexural Strength (MPa)=3PL/(2bd^2 ). Flexural modulus was calculated for each specimen using the following equation: Flexural Modulus (MPa)=(PL^3)/(4Ybd^3 ). Surface properties were then tested using SEM analysis, EDX analysis, and contact angle analysis. To test surface properties, round samples measuring 12 x 2mm were fabricated. Lastly, Candida albicans adhesion was evaluated using the same samples fabricated for surface properties evaluation. Candida albicans adhesion was evaluated by means of CFU counting. Results: Ceramic-reinforced PEEK showed significantly higher flexural strength (p<0.001) than milled and conventional PMMA. Flexural modulus was significantly higher in the BioHPP group (p<0.001). PEEK samples showed greater critical surface tension and surface free energy compared to both PMMA samples. There was no significant difference in CFU counts among the groups. Conclusion: Based on the results of this study, ceramic-reinforced PEEK shows significantly higher flexural strength and flexural modulus compared to both PMMA groups. Surface characterization demonstrates that PEEK samples had a higher polar force as a percentage of surface free energy. There was no statistically significant difference in the mean CFUs/cm2 between polished and unpolished samples.","**To request an accessible version of the file(s) associated with this item, contact library@buffalo.edu. Please include the item's persistent URL [http://hdl.handle.net/. . .] in your request.**"],"dc:identifier":["http://hdl.handle.net/10477/88959"],"dc:language":["eng"],"dc:publisher":["State University of New York at Buffalo"],"dc:rights":["Copyright retained by author. Users of works found in University at Buffalo Institutional Repository (UBIR) are responsible for identifying and contacting the copyright owner for permission to reuse. University at Buffalo Libraries do not manage rights for copyright-protected works and cannot assist with permissions."],"dc:subject":["dentistry"],"dc:title":["Evaluation of Surface and Mechanical Properties of Ceramic-Reinforced PEEK as a Denture Base Material"],"dc:type":["Text","Thesis"]},"updated_at":"2026-11-19T07:10:30Z"}