{"id":{"repo_id":"buffalo","oai_identifier":"oai:ubir.buffalo.edu:10477/89157"},"canonical_url":"https://search.ndltd.org/etd/buffalo/oai:ubir.buffalo.edu:10477/89157","repository":{"repo_id":"buffalo","name":"Buffalo","base_url":"https://ubir.buffalo.edu/oai/request"},"display":{"title":"An Evaluation of Retention of PEEK versus CoCr RPD Frameworks When Utilizing Zirconia Survey Crowns: In-Vitro Study","abstract":"Purpose: The aim of this study was to assess the retention of polyetheretherketone (PEEK) and cobalt chromium (CoCr) as a removable partial denture framework material when zirconia (ZrO2) is used as the survey crown material. Hypothesis: The hypothesis was that PEEK and CoCr RPD frameworks with zirconia survey crowns (ZrC) provide a similar retention as CoCr RPD frameworks with complete cast survey crowns (CCC). Materials and Methods: Thirty partially edentulous mandibular typodonts were used in this study. The three groups tested in this study were CCC-CoCr, ZrC-CoCr, and ZrC-PEEK. The control group was CCC-CoCr, while the test groups were ZrC-CoCr and ZrC-PEEK. There were ten samples in each group. Tooth number eighteen was a standard tooth preparation that received a survey crown, while tooth number twenty-one was the other abutment tooth, which was manually prepared. After the tooth modifications, complete cast and zirconia survey crowns were designed utilizing Dental System (3Shape A/S). PVS impressions were made of the typodonts for RPD fabrication after survey crown cementation. The PVS impressions were poured up in Resin Rock (Whipmix) and the frameworks were designed in Dental System (3Shape A/S). The RPD framework materials utilized were CoCr and PEEK. After the accuracy of fit was confirmed on the typodonts, PMMA rims were added to the frameworks as a retentive fixture for a mechanical pull test to assess the initial retention in Newtons (N) of the RPD frameworks. Each sample was pulled ten times using a universal testing machine (Dillon Quantrol TC2i; Dillon). The peak retentive force in Newtons (N) was recorded for each sample using the software program MultiTest-XT Force Testing System by Mecmesin. The statistical analysis was performed with Microsoft Excel and Graphpad PRISM software programs. Results: The average retentive values for CCC-CoCr, ZrC-CoCr, and ZrC-PEEK were 11.389 N, 11.456 N, and 3.194 N, respectively. The one-way ANOVA test showed a significant (p=0.0073) difference between groups. The results of the Tukey HSD post hoc test of multiple comparisons showed that there was not a significant difference between the CCC-CoCr and ZrC-CoCr groups (p=0.9989). However, there was a significant difference between the CCC-CoCr and ZrC-PEEK (p=0.0151) as well as the ZrC-CoCr and ZrC-PEEK (p=0.0168) groups. Conclusions: Within the limitations of this study, CoCr as a RPD framework material displayed significantly higher retentive values in comparison to PEEK, when zirconia was utilized as the survey crown material.","abstract_html":"Purpose: The aim of this study was to assess the retention of polyetheretherketone (PEEK) and cobalt chromium (CoCr) as a removable partial denture framework material when zirconia (ZrO2) is used as the survey crown material. Hypothesis: The hypothesis was that PEEK and CoCr RPD frameworks with zirconia survey crowns (ZrC) provide a similar retention as CoCr RPD frameworks with complete cast survey crowns (CCC). Materials and Methods: Thirty partially edentulous mandibular typodonts were used in this study. The three groups tested in this study were CCC-CoCr, ZrC-CoCr, and ZrC-PEEK. The control group was CCC-CoCr, while the test groups were ZrC-CoCr and ZrC-PEEK. There were ten samples in each group. Tooth number eighteen was a standard tooth preparation that received a survey crown, while tooth number twenty-one was the other abutment tooth, which was manually prepared. After the tooth modifications, complete cast and zirconia survey crowns were designed utilizing Dental System (3Shape A/S). PVS impressions were made of the typodonts for RPD fabrication after survey crown cementation. The PVS impressions were poured up in Resin Rock (Whipmix) and the frameworks were designed in Dental System (3Shape A/S). The RPD framework materials utilized were CoCr and PEEK. After the accuracy of fit was confirmed on the typodonts, PMMA rims were added to the frameworks as a retentive fixture for a mechanical pull test to assess the initial retention in Newtons (N) of the RPD frameworks. Each sample was pulled ten times using a universal testing machine (Dillon Quantrol TC2i; Dillon). The peak retentive force in Newtons (N) was recorded for each sample using the software program MultiTest-XT Force Testing System by Mecmesin. The statistical analysis was performed with Microsoft Excel and Graphpad PRISM software programs. Results: The average retentive values for CCC-CoCr, ZrC-CoCr, and ZrC-PEEK were 11.389 N, 11.456 N, and 3.194 N, respectively. The one-way ANOVA test showed a significant (p=0.0073) difference between groups. The results of the Tukey HSD post hoc test of multiple comparisons showed that there was not a significant difference between the CCC-CoCr and ZrC-CoCr groups (p=0.9989). However, there was a significant difference between the CCC-CoCr and ZrC-PEEK (p=0.0151) as well as the ZrC-CoCr and ZrC-PEEK (p=0.0168) groups. Conclusions: Within the limitations of this study, CoCr as a RPD framework material displayed significantly higher retentive values in comparison to PEEK, when zirconia was utilized as the survey crown material.","abstract_has_math":false,"creators":["Mendel, Ariana"],"institution":"State University of New York at Buffalo","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":["Sadid-Zadeh, Ramtin","Oral Biology"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2023,"date_issued":"2023","date_published":"2023","updated_at":"2026-11-19T07:10:35Z","subjects":["dentistry"],"languages":["eng"],"rights":["Copyright retained by author. Users of works found in University at Buffalo Institutional Repository (UBIR) are responsible for identifying and contacting the copyright owner for permission to reuse. University at Buffalo Libraries do not manage rights for copyright-protected works and cannot assist with permissions."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10477/89157","outbound_label":"Handle","outbound_source":"dc:identifier","record_url":"https://hdl.handle.net/10477/89157","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Abuffalo%3Aoai%3Aubir.buffalo.edu%3A10477%2F89157","prefix":"oai_dc"},"source_record":{"url":"https://ubir.buffalo.edu/oai/request?verb=GetRecord&metadataPrefix=qdc&identifier=oai%3Aubir.buffalo.edu%3A10477%2F89157","prefix":"qdc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Sadid-Zadeh, Ramtin","Oral Biology"]},{"key":"dc:creator","label":"Author","values":["Mendel, Ariana"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2025-10-08T23:32:08Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-10-08T23:32:08Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2025-10-08T23:32:08Z"]},{"key":"dc:date.issued","label":"Date","values":["2023"]},{"key":"dc:publisher","label":"Institution","values":["State University of New York at Buffalo"]},{"key":"dc:type","label":"Dc Type","values":["Text","Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["dentistry"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright retained by author. Users of works found in University at Buffalo Institutional Repository (UBIR) are responsible for identifying and contacting the copyright owner for permission to reuse. University at Buffalo Libraries do not manage rights for copyright-protected works and cannot assist with permissions."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/10477/89157"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Purpose: The aim of this study was to assess the retention of polyetheretherketone (PEEK) and cobalt chromium (CoCr) as a removable partial denture framework material when zirconia (ZrO2) is used as the survey crown material. Hypothesis: The hypothesis was that PEEK and CoCr RPD frameworks with zirconia survey crowns (ZrC) provide a similar retention as CoCr RPD frameworks with complete cast survey crowns (CCC). Materials and Methods: Thirty partially edentulous mandibular typodonts were used in this study. The three groups tested in this study were CCC-CoCr, ZrC-CoCr, and ZrC-PEEK. The control group was CCC-CoCr, while the test groups were ZrC-CoCr and ZrC-PEEK. There were ten samples in each group. Tooth number eighteen was a standard tooth preparation that received a survey crown, while tooth number twenty-one was the other abutment tooth, which was manually prepared. After the tooth modifications, complete cast and zirconia survey crowns were designed utilizing Dental System (3Shape A/S). PVS impressions were made of the typodonts for RPD fabrication after survey crown cementation. The PVS impressions were poured up in Resin Rock (Whipmix) and the frameworks were designed in Dental System (3Shape A/S). The RPD framework materials utilized were CoCr and PEEK. After the accuracy of fit was confirmed on the typodonts, PMMA rims were added to the frameworks as a retentive fixture for a mechanical pull test to assess the initial retention in Newtons (N) of the RPD frameworks. Each sample was pulled ten times using a universal testing machine (Dillon Quantrol TC2i; Dillon). The peak retentive force in Newtons (N) was recorded for each sample using the software program MultiTest-XT Force Testing System by Mecmesin. The statistical analysis was performed with Microsoft Excel and Graphpad PRISM software programs. Results: The average retentive values for CCC-CoCr, ZrC-CoCr, and ZrC-PEEK were 11.389 N, 11.456 N, and 3.194 N, respectively. The one-way ANOVA test showed a significant (p=0.0073) difference between groups. The results of the Tukey HSD post hoc test of multiple comparisons showed that there was not a significant difference between the CCC-CoCr and ZrC-CoCr groups (p=0.9989). However, there was a significant difference between the CCC-CoCr and ZrC-PEEK (p=0.0151) as well as the ZrC-CoCr and ZrC-PEEK (p=0.0168) groups. Conclusions: Within the limitations of this study, CoCr as a RPD framework material displayed significantly higher retentive values in comparison to PEEK, when zirconia was utilized as the survey crown material.","**To request an accessible version of the file(s) associated with this item, contact library@buffalo.edu. Please include the item's persistent URL [http://hdl.handle.net/. . .] in your request.**"]},{"key":"dc:title","label":"Title","values":["An Evaluation of Retention of PEEK versus CoCr RPD Frameworks When Utilizing Zirconia Survey Crowns: In-Vitro Study"]}]}],"canonical_facts":{"dc:contributor":["Sadid-Zadeh, Ramtin","Oral Biology"],"dc:creator":["Mendel, Ariana"],"dc:date":["2025-10-08T23:32:08Z"],"dc:date.available":["2025-10-08T23:32:08Z"],"dc:date.created":["2025-10-08T23:32:08Z"],"dc:date.issued":["2023"],"dc:description.abstract":["Purpose: The aim of this study was to assess the retention of polyetheretherketone (PEEK) and cobalt chromium (CoCr) as a removable partial denture framework material when zirconia (ZrO2) is used as the survey crown material. Hypothesis: The hypothesis was that PEEK and CoCr RPD frameworks with zirconia survey crowns (ZrC) provide a similar retention as CoCr RPD frameworks with complete cast survey crowns (CCC). Materials and Methods: Thirty partially edentulous mandibular typodonts were used in this study. The three groups tested in this study were CCC-CoCr, ZrC-CoCr, and ZrC-PEEK. The control group was CCC-CoCr, while the test groups were ZrC-CoCr and ZrC-PEEK. There were ten samples in each group. Tooth number eighteen was a standard tooth preparation that received a survey crown, while tooth number twenty-one was the other abutment tooth, which was manually prepared. After the tooth modifications, complete cast and zirconia survey crowns were designed utilizing Dental System (3Shape A/S). PVS impressions were made of the typodonts for RPD fabrication after survey crown cementation. The PVS impressions were poured up in Resin Rock (Whipmix) and the frameworks were designed in Dental System (3Shape A/S). The RPD framework materials utilized were CoCr and PEEK. After the accuracy of fit was confirmed on the typodonts, PMMA rims were added to the frameworks as a retentive fixture for a mechanical pull test to assess the initial retention in Newtons (N) of the RPD frameworks. Each sample was pulled ten times using a universal testing machine (Dillon Quantrol TC2i; Dillon). The peak retentive force in Newtons (N) was recorded for each sample using the software program MultiTest-XT Force Testing System by Mecmesin. The statistical analysis was performed with Microsoft Excel and Graphpad PRISM software programs. Results: The average retentive values for CCC-CoCr, ZrC-CoCr, and ZrC-PEEK were 11.389 N, 11.456 N, and 3.194 N, respectively. The one-way ANOVA test showed a significant (p=0.0073) difference between groups. The results of the Tukey HSD post hoc test of multiple comparisons showed that there was not a significant difference between the CCC-CoCr and ZrC-CoCr groups (p=0.9989). However, there was a significant difference between the CCC-CoCr and ZrC-PEEK (p=0.0151) as well as the ZrC-CoCr and ZrC-PEEK (p=0.0168) groups. Conclusions: Within the limitations of this study, CoCr as a RPD framework material displayed significantly higher retentive values in comparison to PEEK, when zirconia was utilized as the survey crown material.","**To request an accessible version of the file(s) associated with this item, contact library@buffalo.edu. Please include the item's persistent URL [http://hdl.handle.net/. . .] in your request.**"],"dc:identifier":["http://hdl.handle.net/10477/89157"],"dc:language":["eng"],"dc:publisher":["State University of New York at Buffalo"],"dc:rights":["Copyright retained by author. Users of works found in University at Buffalo Institutional Repository (UBIR) are responsible for identifying and contacting the copyright owner for permission to reuse. University at Buffalo Libraries do not manage rights for copyright-protected works and cannot assist with permissions."],"dc:subject":["dentistry"],"dc:title":["An Evaluation of Retention of PEEK versus CoCr RPD Frameworks When Utilizing Zirconia Survey Crowns: In-Vitro Study"],"dc:type":["Text","Thesis"]},"updated_at":"2026-11-19T07:10:35Z"}