{"id":{"repo_id":"buffalo","oai_identifier":"oai:ubir.buffalo.edu:10477/89382"},"canonical_url":"https://search.ndltd.org/etd/buffalo/oai:ubir.buffalo.edu:10477/89382","repository":{"repo_id":"buffalo","name":"Buffalo","base_url":"https://ubir.buffalo.edu/oai/request"},"display":{"title":"Computational Modeling of Electrically Stimulated Healing of Chronic Skin Ulcers","abstract":"Existing wound-stimulation devices work on an open loop system that subjects an open wound to a specific voltage and frequency. Although these methods have been successful in the treatment of patients, many lack portability and the means to accurately monitor the site. These typical treatments result in long sedentary time and more bandaging, which reduces treatment time. In this project, a palm-sized stimulation device was designed to deliver the necessary voltage, frequency and safety features to aid in the healing process. In this work, COMSOL Multiphysics was used to generate finite-element-method (FEM) models of human skin, with the properties of each layer taken in account with the goal of modeling the reaction of human skin to an external electrical stimulation within the context of three scenarios: (1) healthy human skin (2) wounded human skin (3) wounded skin with a monitoring sensor. Computational models are used to investigate key physics to determine if the additional electrical input can increase the ionic flow so it can be monitored and accelerated. These investigations are used to provide a platform for future research in the use of organic electrochemical transistors for accelerating the healing process in open wounds.","abstract_html":"Existing wound-stimulation devices work on an open loop system that subjects an open wound to a specific voltage and frequency. Although these methods have been successful in the treatment of patients, many lack portability and the means to accurately monitor the site. These typical treatments result in long sedentary time and more bandaging, which reduces treatment time. In this project, a palm-sized stimulation device was designed to deliver the necessary voltage, frequency and safety features to aid in the healing process. In this work, COMSOL Multiphysics was used to generate finite-element-method (FEM) models of human skin, with the properties of each layer taken in account with the goal of modeling the reaction of human skin to an external electrical stimulation within the context of three scenarios: (1) healthy human skin (2) wounded human skin (3) wounded skin with a monitoring sensor. Computational models are used to investigate key physics to determine if the additional electrical input can increase the ionic flow so it can be monitored and accelerated. These investigations are used to provide a platform for future research in the use of organic electrochemical transistors for accelerating the healing process in open wounds.","abstract_has_math":false,"creators":["Heidrich, James; 0009-0005-2332-6139"],"institution":"State University of New York at Buffalo","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":["Bird, Jonathan","Electrical Engineering"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2024,"date_issued":"2024","date_published":"2024","updated_at":"2026-11-19T07:10:42Z","subjects":["electrical engineering"],"languages":["eng"],"rights":["Copyright retained by author. Users of works found in University at Buffalo Institutional Repository (UBIR) are responsible for identifying and contacting the copyright owner for permission to reuse. University at Buffalo Libraries do not manage rights for copyright-protected works and cannot assist with permissions."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10477/89382","outbound_label":"Handle","outbound_source":"dc:identifier","record_url":"https://hdl.handle.net/10477/89382","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Abuffalo%3Aoai%3Aubir.buffalo.edu%3A10477%2F89382","prefix":"oai_dc"},"source_record":{"url":"https://ubir.buffalo.edu/oai/request?verb=GetRecord&metadataPrefix=qdc&identifier=oai%3Aubir.buffalo.edu%3A10477%2F89382","prefix":"qdc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Bird, Jonathan","Electrical Engineering"]},{"key":"dc:creator","label":"Author","values":["Heidrich, James; 0009-0005-2332-6139"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2025-11-21T18:14:50Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-11-21T18:14:50Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2025-11-21T18:14:50Z"]},{"key":"dc:date.issued","label":"Date","values":["2024"]},{"key":"dc:publisher","label":"Institution","values":["State University of New York at Buffalo"]},{"key":"dc:type","label":"Dc Type","values":["Text","Dissertation"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["electrical engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright retained by author. Users of works found in University at Buffalo Institutional Repository (UBIR) are responsible for identifying and contacting the copyright owner for permission to reuse. University at Buffalo Libraries do not manage rights for copyright-protected works and cannot assist with permissions."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/10477/89382"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Existing wound-stimulation devices work on an open loop system that subjects an open wound to a specific voltage and frequency. Although these methods have been successful in the treatment of patients, many lack portability and the means to accurately monitor the site. These typical treatments result in long sedentary time and more bandaging, which reduces treatment time. In this project, a palm-sized stimulation device was designed to deliver the necessary voltage, frequency and safety features to aid in the healing process. In this work, COMSOL Multiphysics was used to generate finite-element-method (FEM) models of human skin, with the properties of each layer taken in account with the goal of modeling the reaction of human skin to an external electrical stimulation within the context of three scenarios: (1) healthy human skin (2) wounded human skin (3) wounded skin with a monitoring sensor. Computational models are used to investigate key physics to determine if the additional electrical input can increase the ionic flow so it can be monitored and accelerated. These investigations are used to provide a platform for future research in the use of organic electrochemical transistors for accelerating the healing process in open wounds.","**To request an accessible version of the file(s) associated with this item, contact library@buffalo.edu. Please include the item's persistent URL [http://hdl.handle.net/. . .] in your request.**"]},{"key":"dc:title","label":"Title","values":["Computational Modeling of Electrically Stimulated Healing of Chronic Skin Ulcers"]}]}],"canonical_facts":{"dc:contributor":["Bird, Jonathan","Electrical Engineering"],"dc:creator":["Heidrich, James; 0009-0005-2332-6139"],"dc:date":["2025-11-21T18:14:50Z"],"dc:date.available":["2025-11-21T18:14:50Z"],"dc:date.created":["2025-11-21T18:14:50Z"],"dc:date.issued":["2024"],"dc:description.abstract":["Existing wound-stimulation devices work on an open loop system that subjects an open wound to a specific voltage and frequency. Although these methods have been successful in the treatment of patients, many lack portability and the means to accurately monitor the site. These typical treatments result in long sedentary time and more bandaging, which reduces treatment time. In this project, a palm-sized stimulation device was designed to deliver the necessary voltage, frequency and safety features to aid in the healing process. In this work, COMSOL Multiphysics was used to generate finite-element-method (FEM) models of human skin, with the properties of each layer taken in account with the goal of modeling the reaction of human skin to an external electrical stimulation within the context of three scenarios: (1) healthy human skin (2) wounded human skin (3) wounded skin with a monitoring sensor. Computational models are used to investigate key physics to determine if the additional electrical input can increase the ionic flow so it can be monitored and accelerated. These investigations are used to provide a platform for future research in the use of organic electrochemical transistors for accelerating the healing process in open wounds.","**To request an accessible version of the file(s) associated with this item, contact library@buffalo.edu. Please include the item's persistent URL [http://hdl.handle.net/. . .] in your request.**"],"dc:identifier":["http://hdl.handle.net/10477/89382"],"dc:language":["eng"],"dc:publisher":["State University of New York at Buffalo"],"dc:rights":["Copyright retained by author. Users of works found in University at Buffalo Institutional Repository (UBIR) are responsible for identifying and contacting the copyright owner for permission to reuse. University at Buffalo Libraries do not manage rights for copyright-protected works and cannot assist with permissions."],"dc:subject":["electrical engineering"],"dc:title":["Computational Modeling of Electrically Stimulated Healing of Chronic Skin Ulcers"],"dc:type":["Text","Dissertation"]},"updated_at":"2026-11-19T07:10:42Z"}