{"id":{"repo_id":"buffalo","oai_identifier":"oai:ubir.buffalo.edu:10477/89490"},"canonical_url":"https://search.ndltd.org/etd/buffalo/oai:ubir.buffalo.edu:10477/89490","repository":{"repo_id":"buffalo","name":"Buffalo","base_url":"https://ubir.buffalo.edu/oai/request"},"display":{"title":"Optimizing Airflow Distribution in Room with Air Sanitation Device: A Computational Study","abstract":"Indoor air quality is a critical determinant of occupant health and well-being, particularly in enclosed spaces with limited ventilation. This study employs computational fluid dynamics (CFD) simulations to comprehensively analyze the efficacy of a UV-C air sanitation device in enhancing indoor air quality. The research involved CFD simulations of a typical indoor environment representing office meeting scenarios, encompassing nine different configurations integrating the UV-C air sanitation device with the ventilation system. Two key aspects were emphasized in the analysis: the age of air and pathogen transport. The utilization of the \"age of air\" concept as a computational tool indicated that placing the device below the air supply and directing the flow along the longest dimension of the room yielded the best results. Using two devices located on opposite walls enhanced air mixing, thus improving the air quality. However, situating two devices close together created stagnant zones and worsened air quality. Thus, strategic device placement is key to controlling air circulation and enhancing indoor air quality. Moreover, the simulations demonstrated that the UV-C air sanitation device effectively mitigated the transport of airborne pathogens after 400 s of operation, thereby reducing the risk of occupant exposure and potential infection.","abstract_html":"Indoor air quality is a critical determinant of occupant health and well-being, particularly in enclosed spaces with limited ventilation. This study employs computational fluid dynamics (CFD) simulations to comprehensively analyze the efficacy of a UV-C air sanitation device in enhancing indoor air quality. The research involved CFD simulations of a typical indoor environment representing office meeting scenarios, encompassing nine different configurations integrating the UV-C air sanitation device with the ventilation system. Two key aspects were emphasized in the analysis: the age of air and pathogen transport. The utilization of the &quot;age of air&quot; concept as a computational tool indicated that placing the device below the air supply and directing the flow along the longest dimension of the room yielded the best results. Using two devices located on opposite walls enhanced air mixing, thus improving the air quality. However, situating two devices close together created stagnant zones and worsened air quality. Thus, strategic device placement is key to controlling air circulation and enhancing indoor air quality. Moreover, the simulations demonstrated that the UV-C air sanitation device effectively mitigated the transport of airborne pathogens after 400 s of operation, thereby reducing the risk of occupant exposure and potential infection.","abstract_has_math":false,"creators":["Kulkarni, Devdatta Vishwanath"],"institution":"State University of New York at Buffalo","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":["Battaglia, Francine","Mechanical and Aerospace Engineering"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2023,"date_issued":"2023","date_published":"2023","updated_at":"2026-11-19T07:10:44Z","subjects":["mechanical engineering"],"languages":["eng"],"rights":["Copyright retained by author. Users of works found in University at Buffalo Institutional Repository (UBIR) are responsible for identifying and contacting the copyright owner for permission to reuse. University at Buffalo Libraries do not manage rights for copyright-protected works and cannot assist with permissions."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10477/89490","outbound_label":"Handle","outbound_source":"dc:identifier","record_url":"https://hdl.handle.net/10477/89490","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Abuffalo%3Aoai%3Aubir.buffalo.edu%3A10477%2F89490","prefix":"oai_dc"},"source_record":{"url":"https://ubir.buffalo.edu/oai/request?verb=GetRecord&metadataPrefix=qdc&identifier=oai%3Aubir.buffalo.edu%3A10477%2F89490","prefix":"qdc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Battaglia, Francine","Mechanical and Aerospace Engineering"]},{"key":"dc:creator","label":"Author","values":["Kulkarni, Devdatta Vishwanath"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2025-11-25T14:30:33Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-11-25T14:30:33Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2025-11-25T14:30:33Z"]},{"key":"dc:date.issued","label":"Date","values":["2023"]},{"key":"dc:publisher","label":"Institution","values":["State University of New York at Buffalo"]},{"key":"dc:type","label":"Dc Type","values":["Text","Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["mechanical engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright retained by author. Users of works found in University at Buffalo Institutional Repository (UBIR) are responsible for identifying and contacting the copyright owner for permission to reuse. University at Buffalo Libraries do not manage rights for copyright-protected works and cannot assist with permissions."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/10477/89490"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Indoor air quality is a critical determinant of occupant health and well-being, particularly in enclosed spaces with limited ventilation. This study employs computational fluid dynamics (CFD) simulations to comprehensively analyze the efficacy of a UV-C air sanitation device in enhancing indoor air quality. The research involved CFD simulations of a typical indoor environment representing office meeting scenarios, encompassing nine different configurations integrating the UV-C air sanitation device with the ventilation system. Two key aspects were emphasized in the analysis: the age of air and pathogen transport. The utilization of the \"age of air\" concept as a computational tool indicated that placing the device below the air supply and directing the flow along the longest dimension of the room yielded the best results. Using two devices located on opposite walls enhanced air mixing, thus improving the air quality. However, situating two devices close together created stagnant zones and worsened air quality. Thus, strategic device placement is key to controlling air circulation and enhancing indoor air quality. Moreover, the simulations demonstrated that the UV-C air sanitation device effectively mitigated the transport of airborne pathogens after 400 s of operation, thereby reducing the risk of occupant exposure and potential infection.","**To request an accessible version of the file(s) associated with this item, contact library@buffalo.edu. Please include the item's persistent URL [http://hdl.handle.net/. . .] in your request.**"]},{"key":"dc:title","label":"Title","values":["Optimizing Airflow Distribution in Room with Air Sanitation Device: A Computational Study"]}]}],"canonical_facts":{"dc:contributor":["Battaglia, Francine","Mechanical and Aerospace Engineering"],"dc:creator":["Kulkarni, Devdatta Vishwanath"],"dc:date":["2025-11-25T14:30:33Z"],"dc:date.available":["2025-11-25T14:30:33Z"],"dc:date.created":["2025-11-25T14:30:33Z"],"dc:date.issued":["2023"],"dc:description.abstract":["Indoor air quality is a critical determinant of occupant health and well-being, particularly in enclosed spaces with limited ventilation. This study employs computational fluid dynamics (CFD) simulations to comprehensively analyze the efficacy of a UV-C air sanitation device in enhancing indoor air quality. The research involved CFD simulations of a typical indoor environment representing office meeting scenarios, encompassing nine different configurations integrating the UV-C air sanitation device with the ventilation system. Two key aspects were emphasized in the analysis: the age of air and pathogen transport. The utilization of the \"age of air\" concept as a computational tool indicated that placing the device below the air supply and directing the flow along the longest dimension of the room yielded the best results. Using two devices located on opposite walls enhanced air mixing, thus improving the air quality. However, situating two devices close together created stagnant zones and worsened air quality. Thus, strategic device placement is key to controlling air circulation and enhancing indoor air quality. Moreover, the simulations demonstrated that the UV-C air sanitation device effectively mitigated the transport of airborne pathogens after 400 s of operation, thereby reducing the risk of occupant exposure and potential infection.","**To request an accessible version of the file(s) associated with this item, contact library@buffalo.edu. Please include the item's persistent URL [http://hdl.handle.net/. . .] in your request.**"],"dc:identifier":["http://hdl.handle.net/10477/89490"],"dc:language":["eng"],"dc:publisher":["State University of New York at Buffalo"],"dc:rights":["Copyright retained by author. Users of works found in University at Buffalo Institutional Repository (UBIR) are responsible for identifying and contacting the copyright owner for permission to reuse. University at Buffalo Libraries do not manage rights for copyright-protected works and cannot assist with permissions."],"dc:subject":["mechanical engineering"],"dc:title":["Optimizing Airflow Distribution in Room with Air Sanitation Device: A Computational Study"],"dc:type":["Text","Thesis"]},"updated_at":"2026-11-19T07:10:44Z"}