{"id":{"repo_id":"buffalo","oai_identifier":"oai:ubir.buffalo.edu:10477/89583"},"canonical_url":"https://search.ndltd.org/etd/buffalo/oai:ubir.buffalo.edu:10477/89583","repository":{"repo_id":"buffalo","name":"Buffalo","base_url":"https://ubir.buffalo.edu/oai/request"},"display":{"title":"Analysis of Frictional Properties of Customizable 3D-Printed Ceramic Orthodontic Brackets and Tubes (LightForce™): An In-Vitro Study","abstract":"Introduction: Recent advancements in additive manufacturing processes have made it possible for orthodontists to design and deliver genuinely individualized orthodontic treatment to patients. LightForce™ Orthodontic Technologies (LF) has created custom 3D-printed polycrystalline alumina brackets and molar tubes to provide fully customizable fixed appliances. Along with being aesthetic, it is claimed that using LF brackets and tubes provides a shorter treatment duration, partly due to the low-friction material used during fabrication. As the use of custom 3D-printed appliances rises in prevalence, it is imperative to understand their frictional properties to predict their treatment outcomes better. Objectives: The objectives of this in-vitro study were to: 1) analyze the frictional properties of LF 3D-printed polycrystalline alumina brackets compared to injection-molded metal and polycrystalline alumina brackets using stainless steel (SS) and nickel-titanium (NiTi) wires; 2) analyze the frictional properties of LF 3D-printed polycrystalline alumina molar tubes compared to injection-molded metal tubes using SS and NiTi wires; and 3) compare the surface topography between LF and injection-molded brackets and tubes using scanning electron microscopy...Conclusions: 1) The static frictional force of the LF bracket group was higher than that of the ceramic bracket group but comparable to the metal bracket group when using SS wires for sliding mechanics. 2) The static frictional force of the LF bracket group was higher than that of both the ceramic and metal bracket groups when using NiTi wires for the same purpose. 3) NiTi wires showed more static frictional force than SS wires when sliding along LF brackets. 4) For SS and NiTi wires, the mean static frictional force in the LF molar tube group was not statistically different from the metal molar tube group. 5) SS and NiTi wires had comparable mean static frictional force in the LF molar tube group. 6) LF brackets and tubes have a rougher surface texture compared to the injection-molded appliances.","abstract_html":"Introduction: Recent advancements in additive manufacturing processes have made it possible for orthodontists to design and deliver genuinely individualized orthodontic treatment to patients. LightForce™ Orthodontic Technologies (LF) has created custom 3D-printed polycrystalline alumina brackets and molar tubes to provide fully customizable fixed appliances. Along with being aesthetic, it is claimed that using LF brackets and tubes provides a shorter treatment duration, partly due to the low-friction material used during fabrication. As the use of custom 3D-printed appliances rises in prevalence, it is imperative to understand their frictional properties to predict their treatment outcomes better. Objectives: The objectives of this in-vitro study were to: 1) analyze the frictional properties of LF 3D-printed polycrystalline alumina brackets compared to injection-molded metal and polycrystalline alumina brackets using stainless steel (SS) and nickel-titanium (NiTi) wires; 2) analyze the frictional properties of LF 3D-printed polycrystalline alumina molar tubes compared to injection-molded metal tubes using SS and NiTi wires; and 3) compare the surface topography between LF and injection-molded brackets and tubes using scanning electron microscopy...Conclusions: 1) The static frictional force of the LF bracket group was higher than that of the ceramic bracket group but comparable to the metal bracket group when using SS wires for sliding mechanics. 2) The static frictional force of the LF bracket group was higher than that of both the ceramic and metal bracket groups when using NiTi wires for the same purpose. 3) NiTi wires showed more static frictional force than SS wires when sliding along LF brackets. 4) For SS and NiTi wires, the mean static frictional force in the LF molar tube group was not statistically different from the metal molar tube group. 5) SS and NiTi wires had comparable mean static frictional force in the LF molar tube group. 6) LF brackets and tubes have a rougher surface texture compared to the injection-molded appliances.","abstract_has_math":false,"creators":["Lukens, Elizabeth"],"institution":"State University of New York at Buffalo","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":["Gurav, Ashish","Orthodontics"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2024,"date_issued":"2024","date_published":"2024","updated_at":"2026-11-19T07:10:46Z","subjects":["dentistry"],"languages":["eng"],"rights":["Copyright retained by author. Users of works found in University at Buffalo Institutional Repository (UBIR) are responsible for identifying and contacting the copyright owner for permission to reuse. University at Buffalo Libraries do not manage rights for copyright-protected works and cannot assist with permissions."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10477/89583","outbound_label":"Handle","outbound_source":"dc:identifier","record_url":"https://hdl.handle.net/10477/89583","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Abuffalo%3Aoai%3Aubir.buffalo.edu%3A10477%2F89583","prefix":"oai_dc"},"source_record":{"url":"https://ubir.buffalo.edu/oai/request?verb=GetRecord&metadataPrefix=qdc&identifier=oai%3Aubir.buffalo.edu%3A10477%2F89583","prefix":"qdc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Gurav, Ashish","Orthodontics"]},{"key":"dc:creator","label":"Author","values":["Lukens, Elizabeth"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2025-12-03T17:40:24Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-12-03T17:40:24Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2025-12-03T17:40:24Z"]},{"key":"dc:date.issued","label":"Date","values":["2024"]},{"key":"dc:publisher","label":"Institution","values":["State University of New York at Buffalo"]},{"key":"dc:type","label":"Dc Type","values":["Text","Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["dentistry"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright retained by author. Users of works found in University at Buffalo Institutional Repository (UBIR) are responsible for identifying and contacting the copyright owner for permission to reuse. University at Buffalo Libraries do not manage rights for copyright-protected works and cannot assist with permissions."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/10477/89583"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Introduction: Recent advancements in additive manufacturing processes have made it possible for orthodontists to design and deliver genuinely individualized orthodontic treatment to patients. LightForce™ Orthodontic Technologies (LF) has created custom 3D-printed polycrystalline alumina brackets and molar tubes to provide fully customizable fixed appliances. Along with being aesthetic, it is claimed that using LF brackets and tubes provides a shorter treatment duration, partly due to the low-friction material used during fabrication. As the use of custom 3D-printed appliances rises in prevalence, it is imperative to understand their frictional properties to predict their treatment outcomes better. Objectives: The objectives of this in-vitro study were to: 1) analyze the frictional properties of LF 3D-printed polycrystalline alumina brackets compared to injection-molded metal and polycrystalline alumina brackets using stainless steel (SS) and nickel-titanium (NiTi) wires; 2) analyze the frictional properties of LF 3D-printed polycrystalline alumina molar tubes compared to injection-molded metal tubes using SS and NiTi wires; and 3) compare the surface topography between LF and injection-molded brackets and tubes using scanning electron microscopy...Conclusions: 1) The static frictional force of the LF bracket group was higher than that of the ceramic bracket group but comparable to the metal bracket group when using SS wires for sliding mechanics. 2) The static frictional force of the LF bracket group was higher than that of both the ceramic and metal bracket groups when using NiTi wires for the same purpose. 3) NiTi wires showed more static frictional force than SS wires when sliding along LF brackets. 4) For SS and NiTi wires, the mean static frictional force in the LF molar tube group was not statistically different from the metal molar tube group. 5) SS and NiTi wires had comparable mean static frictional force in the LF molar tube group. 6) LF brackets and tubes have a rougher surface texture compared to the injection-molded appliances.","**To request an accessible version of the file(s) associated with this item, contact library@buffalo.edu. Please include the item's persistent URL [http://hdl.handle.net/. . .] in your request.**"]},{"key":"dc:title","label":"Title","values":["Analysis of Frictional Properties of Customizable 3D-Printed Ceramic Orthodontic Brackets and Tubes (LightForce™): An In-Vitro Study"]}]}],"canonical_facts":{"dc:contributor":["Gurav, Ashish","Orthodontics"],"dc:creator":["Lukens, Elizabeth"],"dc:date":["2025-12-03T17:40:24Z"],"dc:date.available":["2025-12-03T17:40:24Z"],"dc:date.created":["2025-12-03T17:40:24Z"],"dc:date.issued":["2024"],"dc:description.abstract":["Introduction: Recent advancements in additive manufacturing processes have made it possible for orthodontists to design and deliver genuinely individualized orthodontic treatment to patients. LightForce™ Orthodontic Technologies (LF) has created custom 3D-printed polycrystalline alumina brackets and molar tubes to provide fully customizable fixed appliances. Along with being aesthetic, it is claimed that using LF brackets and tubes provides a shorter treatment duration, partly due to the low-friction material used during fabrication. As the use of custom 3D-printed appliances rises in prevalence, it is imperative to understand their frictional properties to predict their treatment outcomes better. Objectives: The objectives of this in-vitro study were to: 1) analyze the frictional properties of LF 3D-printed polycrystalline alumina brackets compared to injection-molded metal and polycrystalline alumina brackets using stainless steel (SS) and nickel-titanium (NiTi) wires; 2) analyze the frictional properties of LF 3D-printed polycrystalline alumina molar tubes compared to injection-molded metal tubes using SS and NiTi wires; and 3) compare the surface topography between LF and injection-molded brackets and tubes using scanning electron microscopy...Conclusions: 1) The static frictional force of the LF bracket group was higher than that of the ceramic bracket group but comparable to the metal bracket group when using SS wires for sliding mechanics. 2) The static frictional force of the LF bracket group was higher than that of both the ceramic and metal bracket groups when using NiTi wires for the same purpose. 3) NiTi wires showed more static frictional force than SS wires when sliding along LF brackets. 4) For SS and NiTi wires, the mean static frictional force in the LF molar tube group was not statistically different from the metal molar tube group. 5) SS and NiTi wires had comparable mean static frictional force in the LF molar tube group. 6) LF brackets and tubes have a rougher surface texture compared to the injection-molded appliances.","**To request an accessible version of the file(s) associated with this item, contact library@buffalo.edu. Please include the item's persistent URL [http://hdl.handle.net/. . .] in your request.**"],"dc:identifier":["http://hdl.handle.net/10477/89583"],"dc:language":["eng"],"dc:publisher":["State University of New York at Buffalo"],"dc:rights":["Copyright retained by author. Users of works found in University at Buffalo Institutional Repository (UBIR) are responsible for identifying and contacting the copyright owner for permission to reuse. University at Buffalo Libraries do not manage rights for copyright-protected works and cannot assist with permissions."],"dc:subject":["dentistry"],"dc:title":["Analysis of Frictional Properties of Customizable 3D-Printed Ceramic Orthodontic Brackets and Tubes (LightForce™): An In-Vitro Study"],"dc:type":["Text","Thesis"]},"updated_at":"2026-11-19T07:10:46Z"}