{"id":{"repo_id":"buffalo","oai_identifier":"oai:ubir.buffalo.edu:10477/89620"},"canonical_url":"https://search.ndltd.org/etd/buffalo/oai:ubir.buffalo.edu:10477/89620","repository":{"repo_id":"buffalo","name":"Buffalo","base_url":"https://ubir.buffalo.edu/oai/request"},"display":{"title":"Cell Sheet Engineering for Vascular and Skin Graft Regenerative Applications","abstract":"Trypsinization has been one of the gold standards for harvesting adherent cells from a culture dish. However, due to the excessive proteolytic activity of trypsin, it will cleave growth factor receptors and membrane proteins found on the surface of the cell. Therefore, collecting cells using this method may have damaged cell membranes and a disrupted extracellular matrix (ECM) which may lead the cells to undergo apoptosis or become damaged in a way that affects the overall function of the cell. One solution is to seed cells on thin film polymeric formulations that undergo a lower critical solution temperature (LCST) phase transition allowing it to separate from underlying surfaces. This research aimed to formulate a modified surface using a temperature sensitive polymer to generate these cell sheets to preserve the cell. This research also focused on improving biocompatible thermoresponsive cell culture surfaces by incorporating collagen to generate the cell sheets which can then be used for two applications: skin graft and vascular grafts. In order to generate these cell sheets, the polymer poly (N-isopropyl acrylamide) (pNIPAAm) was used to “coat” the cell culture (polystyrene) dish with and without collagen. Contact angle and surface release were assessed with digital imaging to determine the thermoresponsiveness of the polymer at various temperatures. To determine if the addition of collagen improved cell viability, human keratinocytes (HaCaT) cells were seeded at 3.5 x 10^5 cells per dish, and viability was assessed at 24 hours using the AlamarBlue assay. We noted that increasing the temperature (from 25℃ to 45℃ n = 3, p < 0.05) increased the contact angle (from 28.75° to 47.75° n = 2, p < 0.05) of the collagen matrix, indicating it would be more hydrophobic and separate from the underlying plastic surface. We observed minimal (n = 3, p > 0.05) cell toxicity in collagen-infused matrix formulations compared to controls, indicating excellent biocompatibility. Finally, altering the temperature (from 25℃ to 45℃) released cell sheets more discreetly than controls. This work demonstrates the utility of cell sheet engineering with poly (N-Isopropyl acrylamide) mixed with collagen for optimal cell compatibility and enhanced characteristics of thermoresponsiveness. The cell sheets can be manipulated to generate wound dressings and vascular conduits for various clinical regenerative applications.","abstract_html":"Trypsinization has been one of the gold standards for harvesting adherent cells from a culture dish. However, due to the excessive proteolytic activity of trypsin, it will cleave growth factor receptors and membrane proteins found on the surface of the cell. Therefore, collecting cells using this method may have damaged cell membranes and a disrupted extracellular matrix (ECM) which may lead the cells to undergo apoptosis or become damaged in a way that affects the overall function of the cell. One solution is to seed cells on thin film polymeric formulations that undergo a lower critical solution temperature (LCST) phase transition allowing it to separate from underlying surfaces. This research aimed to formulate a modified surface using a temperature sensitive polymer to generate these cell sheets to preserve the cell. This research also focused on improving biocompatible thermoresponsive cell culture surfaces by incorporating collagen to generate the cell sheets which can then be used for two applications: skin graft and vascular grafts. In order to generate these cell sheets, the polymer poly (N-isopropyl acrylamide) (pNIPAAm) was used to “coat” the cell culture (polystyrene) dish with and without collagen. Contact angle and surface release were assessed with digital imaging to determine the thermoresponsiveness of the polymer at various temperatures. To determine if the addition of collagen improved cell viability, human keratinocytes (HaCaT) cells were seeded at 3.5 x 10^5 cells per dish, and viability was assessed at 24 hours using the AlamarBlue assay. We noted that increasing the temperature (from 25℃ to 45℃ n = 3, p &lt; 0.05) increased the contact angle (from 28.75° to 47.75° n = 2, p &lt; 0.05) of the collagen matrix, indicating it would be more hydrophobic and separate from the underlying plastic surface. We observed minimal (n = 3, p &gt; 0.05) cell toxicity in collagen-infused matrix formulations compared to controls, indicating excellent biocompatibility. Finally, altering the temperature (from 25℃ to 45℃) released cell sheets more discreetly than controls. This work demonstrates the utility of cell sheet engineering with poly (N-Isopropyl acrylamide) mixed with collagen for optimal cell compatibility and enhanced characteristics of thermoresponsiveness. The cell sheets can be manipulated to generate wound dressings and vascular conduits for various clinical regenerative applications.","abstract_has_math":false,"creators":["Sarker, Shanjidah"],"institution":"State University of New York at Buffalo","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":["Arany, Praveen","Biomedical Engineering"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2024,"date_issued":"2024","date_published":"2024","updated_at":"2026-11-19T07:10:46Z","subjects":["biomedical engineering"],"languages":["eng"],"rights":["Copyright retained by author. Users of works found in University at Buffalo Institutional Repository (UBIR) are responsible for identifying and contacting the copyright owner for permission to reuse. University at Buffalo Libraries do not manage rights for copyright-protected works and cannot assist with permissions."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10477/89620","outbound_label":"Handle","outbound_source":"dc:identifier","record_url":"https://hdl.handle.net/10477/89620","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Abuffalo%3Aoai%3Aubir.buffalo.edu%3A10477%2F89620","prefix":"oai_dc"},"source_record":{"url":"https://ubir.buffalo.edu/oai/request?verb=GetRecord&metadataPrefix=qdc&identifier=oai%3Aubir.buffalo.edu%3A10477%2F89620","prefix":"qdc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Arany, Praveen","Biomedical Engineering"]},{"key":"dc:creator","label":"Author","values":["Sarker, Shanjidah"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2025-12-03T17:40:44Z","2024","2024-05-14 00:11:16"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-12-03T17:40:44Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2025-12-03T17:40:44Z"]},{"key":"dc:date.issued","label":"Date","values":["2024"]},{"key":"dc:publisher","label":"Institution","values":["State University of New York at Buffalo"]},{"key":"dc:type","label":"Dc Type","values":["Text","Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["biomedical engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright retained by author. Users of works found in University at Buffalo Institutional Repository (UBIR) are responsible for identifying and contacting the copyright owner for permission to reuse. University at Buffalo Libraries do not manage rights for copyright-protected works and cannot assist with permissions."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/10477/89620"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["M.S.","Trypsinization has been one of the gold standards for harvesting adherent cells from a culture dish. However, due to the excessive proteolytic activity of trypsin, it will cleave growth factor receptors and membrane proteins found on the surface of the cell. Therefore, collecting cells using this method may have damaged cell membranes and a disrupted extracellular matrix (ECM) which may lead the cells to undergo apoptosis or become damaged in a way that affects the overall function of the cell. One solution is to seed cells on thin film polymeric formulations that undergo a lower critical solution temperature (LCST) phase transition allowing it to separate from underlying surfaces. This research aimed to formulate a modified surface using a temperature sensitive polymer to generate these cell sheets to preserve the cell. This research also focused on improving biocompatible thermoresponsive cell culture surfaces by incorporating collagen to generate the cell sheets which can then be used for two applications: skin graft and vascular grafts. In order to generate these cell sheets, the polymer poly (N-isopropyl acrylamide) (pNIPAAm) was used to “coat” the cell culture (polystyrene) dish with and without collagen. Contact angle and surface release were assessed with digital imaging to determine the thermoresponsiveness of the polymer at various temperatures. To determine if the addition of collagen improved cell viability, human keratinocytes (HaCaT) cells were seeded at 3.5 x 10^5 cells per dish, and viability was assessed at 24 hours using the AlamarBlue assay. We noted that increasing the temperature (from 25℃ to 45℃ n = 3, p < 0.05) increased the contact angle (from 28.75° to 47.75° n = 2, p < 0.05) of the collagen matrix, indicating it would be more hydrophobic and separate from the underlying plastic surface. We observed minimal (n = 3, p > 0.05) cell toxicity in collagen-infused matrix formulations compared to controls, indicating excellent biocompatibility. Finally, altering the temperature (from 25℃ to 45℃) released cell sheets more discreetly than controls. This work demonstrates the utility of cell sheet engineering with poly (N-Isopropyl acrylamide) mixed with collagen for optimal cell compatibility and enhanced characteristics of thermoresponsiveness. The cell sheets can be manipulated to generate wound dressings and vascular conduits for various clinical regenerative applications.","**To request an accessible version of the file(s) associated with this item, contact library@buffalo.edu. Please include the item's persistent URL [http://hdl.handle.net/. . .] in your request.**"]},{"key":"dc:description.abstract","label":"Abstract","values":["Trypsinization has been one of the gold standards for harvesting adherent cells from a culture dish. However, due to the excessive proteolytic activity of trypsin, it will cleave growth factor receptors and membrane proteins found on the surface of the cell. Therefore, collecting cells using this method may have damaged cell membranes and a disrupted extracellular matrix (ECM) which may lead the cells to undergo apoptosis or become damaged in a way that affects the overall function of the cell. One solution is to seed cells on thin film polymeric formulations that undergo a lower critical solution temperature (LCST) phase transition allowing it to separate from underlying surfaces. This research aimed to formulate a modified surface using a temperature sensitive polymer to generate these cell sheets to preserve the cell. This research also focused on improving biocompatible thermoresponsive cell culture surfaces by incorporating collagen to generate the cell sheets which can then be used for two applications: skin graft and vascular grafts. In order to generate these cell sheets, the polymer poly (N-isopropyl acrylamide) (pNIPAAm) was used to “coat” the cell culture (polystyrene) dish with and without collagen. Contact angle and surface release were assessed with digital imaging to determine the thermoresponsiveness of the polymer at various temperatures. To determine if the addition of collagen improved cell viability, human keratinocytes (HaCaT) cells were seeded at 3.5 x 10^5 cells per dish, and viability was assessed at 24 hours using the AlamarBlue assay. We noted that increasing the temperature (from 25℃ to 45℃ n = 3, p < 0.05) increased the contact angle (from 28.75° to 47.75° n = 2, p < 0.05) of the collagen matrix, indicating it would be more hydrophobic and separate from the underlying plastic surface. We observed minimal (n = 3, p > 0.05) cell toxicity in collagen-infused matrix formulations compared to controls, indicating excellent biocompatibility. Finally, altering the temperature (from 25℃ to 45℃) released cell sheets more discreetly than controls. This work demonstrates the utility of cell sheet engineering with poly (N-Isopropyl acrylamide) mixed with collagen for optimal cell compatibility and enhanced characteristics of thermoresponsiveness. The cell sheets can be manipulated to generate wound dressings and vascular conduits for various clinical regenerative applications.","**To request an accessible version of the file(s) associated with this item, contact library@buffalo.edu. Please include the item's persistent URL [http://hdl.handle.net/. . .] in your request.**"]},{"key":"dc:format","label":"Dc Format","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Cell Sheet Engineering for Vascular and Skin Graft Regenerative Applications"]}]}],"canonical_facts":{"dc:contributor":["Arany, Praveen","Biomedical Engineering"],"dc:creator":["Sarker, Shanjidah"],"dc:date":["2025-12-03T17:40:44Z","2024","2024-05-14 00:11:16"],"dc:date.available":["2025-12-03T17:40:44Z"],"dc:date.created":["2025-12-03T17:40:44Z"],"dc:date.issued":["2024"],"dc:description":["M.S.","Trypsinization has been one of the gold standards for harvesting adherent cells from a culture dish. However, due to the excessive proteolytic activity of trypsin, it will cleave growth factor receptors and membrane proteins found on the surface of the cell. Therefore, collecting cells using this method may have damaged cell membranes and a disrupted extracellular matrix (ECM) which may lead the cells to undergo apoptosis or become damaged in a way that affects the overall function of the cell. One solution is to seed cells on thin film polymeric formulations that undergo a lower critical solution temperature (LCST) phase transition allowing it to separate from underlying surfaces. This research aimed to formulate a modified surface using a temperature sensitive polymer to generate these cell sheets to preserve the cell. This research also focused on improving biocompatible thermoresponsive cell culture surfaces by incorporating collagen to generate the cell sheets which can then be used for two applications: skin graft and vascular grafts. In order to generate these cell sheets, the polymer poly (N-isopropyl acrylamide) (pNIPAAm) was used to “coat” the cell culture (polystyrene) dish with and without collagen. Contact angle and surface release were assessed with digital imaging to determine the thermoresponsiveness of the polymer at various temperatures. To determine if the addition of collagen improved cell viability, human keratinocytes (HaCaT) cells were seeded at 3.5 x 10^5 cells per dish, and viability was assessed at 24 hours using the AlamarBlue assay. We noted that increasing the temperature (from 25℃ to 45℃ n = 3, p < 0.05) increased the contact angle (from 28.75° to 47.75° n = 2, p < 0.05) of the collagen matrix, indicating it would be more hydrophobic and separate from the underlying plastic surface. We observed minimal (n = 3, p > 0.05) cell toxicity in collagen-infused matrix formulations compared to controls, indicating excellent biocompatibility. Finally, altering the temperature (from 25℃ to 45℃) released cell sheets more discreetly than controls. This work demonstrates the utility of cell sheet engineering with poly (N-Isopropyl acrylamide) mixed with collagen for optimal cell compatibility and enhanced characteristics of thermoresponsiveness. The cell sheets can be manipulated to generate wound dressings and vascular conduits for various clinical regenerative applications.","**To request an accessible version of the file(s) associated with this item, contact library@buffalo.edu. Please include the item's persistent URL [http://hdl.handle.net/. . .] in your request.**"],"dc:description.abstract":["Trypsinization has been one of the gold standards for harvesting adherent cells from a culture dish. However, due to the excessive proteolytic activity of trypsin, it will cleave growth factor receptors and membrane proteins found on the surface of the cell. Therefore, collecting cells using this method may have damaged cell membranes and a disrupted extracellular matrix (ECM) which may lead the cells to undergo apoptosis or become damaged in a way that affects the overall function of the cell. One solution is to seed cells on thin film polymeric formulations that undergo a lower critical solution temperature (LCST) phase transition allowing it to separate from underlying surfaces. This research aimed to formulate a modified surface using a temperature sensitive polymer to generate these cell sheets to preserve the cell. This research also focused on improving biocompatible thermoresponsive cell culture surfaces by incorporating collagen to generate the cell sheets which can then be used for two applications: skin graft and vascular grafts. In order to generate these cell sheets, the polymer poly (N-isopropyl acrylamide) (pNIPAAm) was used to “coat” the cell culture (polystyrene) dish with and without collagen. Contact angle and surface release were assessed with digital imaging to determine the thermoresponsiveness of the polymer at various temperatures. To determine if the addition of collagen improved cell viability, human keratinocytes (HaCaT) cells were seeded at 3.5 x 10^5 cells per dish, and viability was assessed at 24 hours using the AlamarBlue assay. We noted that increasing the temperature (from 25℃ to 45℃ n = 3, p < 0.05) increased the contact angle (from 28.75° to 47.75° n = 2, p < 0.05) of the collagen matrix, indicating it would be more hydrophobic and separate from the underlying plastic surface. We observed minimal (n = 3, p > 0.05) cell toxicity in collagen-infused matrix formulations compared to controls, indicating excellent biocompatibility. Finally, altering the temperature (from 25℃ to 45℃) released cell sheets more discreetly than controls. This work demonstrates the utility of cell sheet engineering with poly (N-Isopropyl acrylamide) mixed with collagen for optimal cell compatibility and enhanced characteristics of thermoresponsiveness. The cell sheets can be manipulated to generate wound dressings and vascular conduits for various clinical regenerative applications.","**To request an accessible version of the file(s) associated with this item, contact library@buffalo.edu. Please include the item's persistent URL [http://hdl.handle.net/. . .] in your request.**"],"dc:format":["application/pdf"],"dc:identifier":["http://hdl.handle.net/10477/89620"],"dc:language":["eng"],"dc:publisher":["State University of New York at Buffalo"],"dc:rights":["Copyright retained by author. Users of works found in University at Buffalo Institutional Repository (UBIR) are responsible for identifying and contacting the copyright owner for permission to reuse. University at Buffalo Libraries do not manage rights for copyright-protected works and cannot assist with permissions."],"dc:subject":["biomedical engineering"],"dc:title":["Cell Sheet Engineering for Vascular and Skin Graft Regenerative Applications"],"dc:type":["Text","Thesis"]},"updated_at":"2026-11-19T07:10:46Z"}