{"id":{"repo_id":"buffalo","oai_identifier":"oai:ubir.buffalo.edu:10477/90396"},"canonical_url":"https://search.ndltd.org/etd/buffalo/oai:ubir.buffalo.edu:10477/90396","repository":{"repo_id":"buffalo","name":"Buffalo","base_url":"https://ubir.buffalo.edu/oai/request"},"display":{"title":"Shear Strength and Color Stability of Temporary Crown and Bridge Materials Fabricated from Subtractive and Additive CAD/CAM Techniques","abstract":"Objective: The aim of this study is to compare the shear strength and color stability of the urethane dimethacrylate Crown & Bridge resin material (TC-80DP, Graphy) to the printed resin (C&B resin, Formlabs), and the milled PMMA discs (Telio Cad, Ivoclar Vivadent). Methods: Three groups of disc specimens (Ø4x14 mm) were designed using CAD software (AutoCAD Inventor). For shear, 13 samples each were manufactured from 3D printed resins by Formlabs and Graphy and also milled with Telio CAD (Ivoclar). The samples were embedded in FastTray PMMA resin (Keystone) and polished (Automet, Beuhler). Then, the samples were sandblasted with 50 microns Al2O3 at 2 bar pressure from a distance of 10 mm for 10 seconds. Specimens were cleaned with deionized water and dried. The specimens were bonded with a bonding agent (Monobond Plus, Ivoclar) and dual cure resin cement (Automix MultiLink; Ivoclar) was bonded to the surface of the specimens using a high-density polyethylene mold. The samples were thermocycled for 5000 cycles at 5 and 55°C (19) and were tested with a shear testing machine (Ultratester; Ultradent) with a crosshead speed of 1 mm/min. One-way ANOVA, followed by the Tukey HSD test was used to compare the impact of surface texture on the shear bond strength at a significance level of 0.05. For color stability, three groups of disc specimens (Ø1.2x14 mm) were designed using CAD software (Autodesk Inventor). Fifteen samples each were manufactured from 3D printed resins by Formlabs and Graphy and also milled with Telio CAD (Ivoclar). The samples were polished with 360, 600, and a final 1200 silicon carbide grit (Automet, Beuhler). Optical properties were assessed using a spectrophotometer (Konica Minolta) with guidance from ISO standard 7491. Measurements were taken using a bench top spectrophotometer (CM-26dg Portable Spectrophotometer; Konica Minolta) with CIE D65 standard illumination and 2° standard observer, against white and black tiles. Color was recorded with L*a*b* coordinates, describing each sample using three parameters: “L*” is the lightness, whereas “a*” is green~magenta with negative values toward green and positive values toward magenta and “b*” is blue~yellow with negative numbers toward blue and positive toward yellow. After the initial data was recorded, the samples were exposed to 5,000 cycles (5 and 55°C) of thermocycling and tested again. (19) The total change in color (ΔE00) was calculated from the CIEDE2000 coordinates as taken from ASTM D2244-16. Data was statistically analyzed using one-way ANOVA, using a significance level of (α=0.05). Tukey’s multiple comparisons test was also completed…","abstract_html":"Objective: The aim of this study is to compare the shear strength and color stability of the urethane dimethacrylate Crown &amp; Bridge resin material (TC-80DP, Graphy) to the printed resin (C&amp;B resin, Formlabs), and the milled PMMA discs (Telio Cad, Ivoclar Vivadent). Methods: Three groups of disc specimens (Ø4x14 mm) were designed using CAD software (AutoCAD Inventor). For shear, 13 samples each were manufactured from 3D printed resins by Formlabs and Graphy and also milled with Telio CAD (Ivoclar). The samples were embedded in FastTray PMMA resin (Keystone) and polished (Automet, Beuhler). Then, the samples were sandblasted with 50 microns Al2O3 at 2 bar pressure from a distance of 10 mm for 10 seconds. Specimens were cleaned with deionized water and dried. The specimens were bonded with a bonding agent (Monobond Plus, Ivoclar) and dual cure resin cement (Automix MultiLink; Ivoclar) was bonded to the surface of the specimens using a high-density polyethylene mold. The samples were thermocycled for 5000 cycles at 5 and 55°C (19) and were tested with a shear testing machine (Ultratester; Ultradent) with a crosshead speed of 1 mm/min. One-way ANOVA, followed by the Tukey HSD test was used to compare the impact of surface texture on the shear bond strength at a significance level of 0.05. For color stability, three groups of disc specimens (Ø1.2x14 mm) were designed using CAD software (Autodesk Inventor). Fifteen samples each were manufactured from 3D printed resins by Formlabs and Graphy and also milled with Telio CAD (Ivoclar). The samples were polished with 360, 600, and a final 1200 silicon carbide grit (Automet, Beuhler). Optical properties were assessed using a spectrophotometer (Konica Minolta) with guidance from ISO standard 7491. Measurements were taken using a bench top spectrophotometer (CM-26dg Portable Spectrophotometer; Konica Minolta) with CIE D65 standard illumination and 2° standard observer, against white and black tiles. Color was recorded with L*a*b* coordinates, describing each sample using three parameters: “L*” is the lightness, whereas “a*” is green~magenta with negative values toward green and positive values toward magenta and “b*” is blue~yellow with negative numbers toward blue and positive toward yellow. After the initial data was recorded, the samples were exposed to 5,000 cycles (5 and 55°C) of thermocycling and tested again. (19) The total change in color (ΔE00) was calculated from the CIEDE2000 coordinates as taken from ASTM D2244-16. Data was statistically analyzed using one-way ANOVA, using a significance level of (α=0.05). Tukey’s multiple comparisons test was also completed…","abstract_has_math":false,"creators":["Raza, Syed Zaeem Hussain; 0009-0007-4150-5514"],"institution":"State University of New York at Buffalo","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":["Kim, Hyeongil","Oral Biology"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2025,"date_issued":"2025","date_published":"2025","updated_at":"2026-11-19T07:11:05Z","subjects":["dentistry"],"languages":["eng"],"rights":["Copyright retained by author. Users of works found in University at Buffalo Institutional Repository (UBIR) are responsible for identifying and contacting the copyright owner for permission to reuse. University at Buffalo Libraries do not manage rights for copyright-protected works and cannot assist with permissions."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10477/90396","outbound_label":"Handle","outbound_source":"dc:identifier","record_url":"https://hdl.handle.net/10477/90396","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Abuffalo%3Aoai%3Aubir.buffalo.edu%3A10477%2F90396","prefix":"oai_dc"},"source_record":{"url":"https://ubir.buffalo.edu/oai/request?verb=GetRecord&metadataPrefix=qdc&identifier=oai%3Aubir.buffalo.edu%3A10477%2F90396","prefix":"qdc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Kim, Hyeongil","Oral Biology"]},{"key":"dc:creator","label":"Author","values":["Raza, Syed Zaeem Hussain; 0009-0007-4150-5514"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2026-02-26T00:48:49Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2026-02-26T00:48:49Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2026-02-26T00:48:49Z"]},{"key":"dc:date.issued","label":"Date","values":["2025"]},{"key":"dc:publisher","label":"Institution","values":["State University of New York at Buffalo"]},{"key":"dc:type","label":"Dc Type","values":["Text","Thesis"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["dentistry"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["Copyright retained by author. Users of works found in University at Buffalo Institutional Repository (UBIR) are responsible for identifying and contacting the copyright owner for permission to reuse. University at Buffalo Libraries do not manage rights for copyright-protected works and cannot assist with permissions."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["http://hdl.handle.net/10477/90396"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Objective: The aim of this study is to compare the shear strength and color stability of the urethane dimethacrylate Crown & Bridge resin material (TC-80DP, Graphy) to the printed resin (C&B resin, Formlabs), and the milled PMMA discs (Telio Cad, Ivoclar Vivadent). Methods: Three groups of disc specimens (Ø4x14 mm) were designed using CAD software (AutoCAD Inventor). For shear, 13 samples each were manufactured from 3D printed resins by Formlabs and Graphy and also milled with Telio CAD (Ivoclar). The samples were embedded in FastTray PMMA resin (Keystone) and polished (Automet, Beuhler). Then, the samples were sandblasted with 50 microns Al2O3 at 2 bar pressure from a distance of 10 mm for 10 seconds. Specimens were cleaned with deionized water and dried. The specimens were bonded with a bonding agent (Monobond Plus, Ivoclar) and dual cure resin cement (Automix MultiLink; Ivoclar) was bonded to the surface of the specimens using a high-density polyethylene mold. The samples were thermocycled for 5000 cycles at 5 and 55°C (19) and were tested with a shear testing machine (Ultratester; Ultradent) with a crosshead speed of 1 mm/min. One-way ANOVA, followed by the Tukey HSD test was used to compare the impact of surface texture on the shear bond strength at a significance level of 0.05. For color stability, three groups of disc specimens (Ø1.2x14 mm) were designed using CAD software (Autodesk Inventor). Fifteen samples each were manufactured from 3D printed resins by Formlabs and Graphy and also milled with Telio CAD (Ivoclar). The samples were polished with 360, 600, and a final 1200 silicon carbide grit (Automet, Beuhler). Optical properties were assessed using a spectrophotometer (Konica Minolta) with guidance from ISO standard 7491. Measurements were taken using a bench top spectrophotometer (CM-26dg Portable Spectrophotometer; Konica Minolta) with CIE D65 standard illumination and 2° standard observer, against white and black tiles. Color was recorded with L*a*b* coordinates, describing each sample using three parameters: “L*” is the lightness, whereas “a*” is green~magenta with negative values toward green and positive values toward magenta and “b*” is blue~yellow with negative numbers toward blue and positive toward yellow. After the initial data was recorded, the samples were exposed to 5,000 cycles (5 and 55°C) of thermocycling and tested again. (19) The total change in color (ΔE00) was calculated from the CIEDE2000 coordinates as taken from ASTM D2244-16. Data was statistically analyzed using one-way ANOVA, using a significance level of (α=0.05). Tukey’s multiple comparisons test was also completed…","**To request an accessible version of the file(s) associated with this item, contact library@buffalo.edu. Please include the item's persistent URL [http://hdl.handle.net/. . .] in your request.**"]},{"key":"dc:title","label":"Title","values":["Shear Strength and Color Stability of Temporary Crown and Bridge Materials Fabricated from Subtractive and Additive CAD/CAM Techniques"]}]}],"canonical_facts":{"dc:contributor":["Kim, Hyeongil","Oral Biology"],"dc:creator":["Raza, Syed Zaeem Hussain; 0009-0007-4150-5514"],"dc:date":["2026-02-26T00:48:49Z"],"dc:date.available":["2026-02-26T00:48:49Z"],"dc:date.created":["2026-02-26T00:48:49Z"],"dc:date.issued":["2025"],"dc:description.abstract":["Objective: The aim of this study is to compare the shear strength and color stability of the urethane dimethacrylate Crown & Bridge resin material (TC-80DP, Graphy) to the printed resin (C&B resin, Formlabs), and the milled PMMA discs (Telio Cad, Ivoclar Vivadent). Methods: Three groups of disc specimens (Ø4x14 mm) were designed using CAD software (AutoCAD Inventor). For shear, 13 samples each were manufactured from 3D printed resins by Formlabs and Graphy and also milled with Telio CAD (Ivoclar). The samples were embedded in FastTray PMMA resin (Keystone) and polished (Automet, Beuhler). Then, the samples were sandblasted with 50 microns Al2O3 at 2 bar pressure from a distance of 10 mm for 10 seconds. Specimens were cleaned with deionized water and dried. The specimens were bonded with a bonding agent (Monobond Plus, Ivoclar) and dual cure resin cement (Automix MultiLink; Ivoclar) was bonded to the surface of the specimens using a high-density polyethylene mold. The samples were thermocycled for 5000 cycles at 5 and 55°C (19) and were tested with a shear testing machine (Ultratester; Ultradent) with a crosshead speed of 1 mm/min. One-way ANOVA, followed by the Tukey HSD test was used to compare the impact of surface texture on the shear bond strength at a significance level of 0.05. For color stability, three groups of disc specimens (Ø1.2x14 mm) were designed using CAD software (Autodesk Inventor). Fifteen samples each were manufactured from 3D printed resins by Formlabs and Graphy and also milled with Telio CAD (Ivoclar). The samples were polished with 360, 600, and a final 1200 silicon carbide grit (Automet, Beuhler). Optical properties were assessed using a spectrophotometer (Konica Minolta) with guidance from ISO standard 7491. Measurements were taken using a bench top spectrophotometer (CM-26dg Portable Spectrophotometer; Konica Minolta) with CIE D65 standard illumination and 2° standard observer, against white and black tiles. Color was recorded with L*a*b* coordinates, describing each sample using three parameters: “L*” is the lightness, whereas “a*” is green~magenta with negative values toward green and positive values toward magenta and “b*” is blue~yellow with negative numbers toward blue and positive toward yellow. After the initial data was recorded, the samples were exposed to 5,000 cycles (5 and 55°C) of thermocycling and tested again. (19) The total change in color (ΔE00) was calculated from the CIEDE2000 coordinates as taken from ASTM D2244-16. Data was statistically analyzed using one-way ANOVA, using a significance level of (α=0.05). Tukey’s multiple comparisons test was also completed…","**To request an accessible version of the file(s) associated with this item, contact library@buffalo.edu. Please include the item's persistent URL [http://hdl.handle.net/. . .] in your request.**"],"dc:identifier":["http://hdl.handle.net/10477/90396"],"dc:language":["eng"],"dc:publisher":["State University of New York at Buffalo"],"dc:rights":["Copyright retained by author. Users of works found in University at Buffalo Institutional Repository (UBIR) are responsible for identifying and contacting the copyright owner for permission to reuse. University at Buffalo Libraries do not manage rights for copyright-protected works and cannot assist with permissions."],"dc:subject":["dentistry"],"dc:title":["Shear Strength and Color Stability of Temporary Crown and Bridge Materials Fabricated from Subtractive and Additive CAD/CAM Techniques"],"dc:type":["Text","Thesis"]},"updated_at":"2026-11-19T07:11:05Z"}