{"id":{"repo_id":"byu","oai_identifier":"oai:scholarsarchive.byu.edu:etd-3825"},"canonical_url":"https://search.ndltd.org/etd/byu/oai:scholarsarchive.byu.edu:etd-3825","repository":{"repo_id":"byu","name":"Brigham Young University","base_url":"https://scholarsarchive.byu.edu/do/oai/"},"display":{"title":"Characterization of the Desorption Electrospray Ionization Mechanism Using Microscopic Imaging of the Sample Surface","abstract":"Desorption electrospray ionization (DESI) is an ambient ionization technique for mass spectrometry. This solvent based desorption ion source has wide applicability in surface analysis with minimal sample preparation. Interest in improving detection limits, broadening applications, and increasing the spatial resolution for chemical imaging has led to studies of the DESI mechanism. An inverted microscope has been used to image interactions between the DESI spray and test analytes on a glass surface. Microscopic images recorded with millisecond time resolution have provided important insights into the processes governing analyte transport and desorption. These insights are the basis of a rivulet-based model for desorption that differs significantly from the widely-accepted momentum transfer model.","abstract_html":"Desorption electrospray ionization (DESI) is an ambient ionization technique for mass spectrometry. This solvent based desorption ion source has wide applicability in surface analysis with minimal sample preparation. Interest in improving detection limits, broadening applications, and increasing the spatial resolution for chemical imaging has led to studies of the DESI mechanism. An inverted microscope has been used to image interactions between the DESI spray and test analytes on a glass surface. Microscopic images recorded with millisecond time resolution have provided important insights into the processes governing analyte transport and desorption. These insights are the basis of a rivulet-based model for desorption that differs significantly from the widely-accepted momentum transfer model.","abstract_has_math":false,"creators":["Wood, Michael Craig"],"institution":"Brigham Young University - Provo","degree_name":"PhD","degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2011,"date_issued":"2011-08-04T07:00:00Z","date_published":"2011-08-04T07:00:00Z","updated_at":"2026-11-27T02:25:28Z","subjects":["DESI","Desorption Electrospray Ionization","Microscopic","Imaging","Real-time","Mechanism","Fluorescence","Absorption","Coating","Rivulets","Mass Spectrometry","Biochemistry","Chemistry"],"languages":["English"],"rights":[],"rights_urls":["http://lib.byu.edu/about/copyright/"],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://scholarsarchive.byu.edu/etd/2826","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://scholarsarchive.byu.edu/etd/2826","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Abyu%3Aoai%3Ascholarsarchive.byu.edu%3Aetd-3825","prefix":"oai_dc"},"source_record":{"url":"https://scholarsarchive.byu.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Ascholarsarchive.byu.edu%3Aetd-3825","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Wood, Michael Craig"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2011-08-04T07:00:00Z"]},{"key":"dc:publisher","label":"Institution","values":["Brigham Young University - Provo"]},{"key":"dc:type","label":"Dc Type","values":["Dissertation"]},{"key":"thesis:degree_name","label":"Degree Name","values":["PhD"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["DESI","Desorption Electrospray Ionization","Microscopic","Imaging","Real-time","Mechanism","Fluorescence","Absorption","Coating","Rivulets","Mass Spectrometry","Biochemistry","Chemistry"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights.license","label":"Dc Rights License","values":["http://lib.byu.edu/about/copyright/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://scholarsarchive.byu.edu/etd/2826"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Physical and Mathematical Sciences","Chemistry and Biochemistry"]},{"key":"dc:description.abstract","label":"Abstract","values":["Desorption electrospray ionization (DESI) is an ambient ionization technique for mass spectrometry. This solvent based desorption ion source has wide applicability in surface analysis with minimal sample preparation. Interest in improving detection limits, broadening applications, and increasing the spatial resolution for chemical imaging has led to studies of the DESI mechanism. An inverted microscope has been used to image interactions between the DESI spray and test analytes on a glass surface. Microscopic images recorded with millisecond time resolution have provided important insights into the processes governing analyte transport and desorption. These insights are the basis of a rivulet-based model for desorption that differs significantly from the widely-accepted momentum transfer model."]},{"key":"dc:format","label":"Dc Format","values":["application: pdf"]},{"key":"dc:source","label":"Dc Source","values":["Brigham Young University - Provo"]},{"key":"dc:title","label":"Title","values":["Characterization of the Desorption Electrospray Ionization Mechanism Using Microscopic Imaging of the Sample Surface"]}]}],"canonical_facts":{"dc:creator":["Wood, Michael Craig"],"dc:date":["2011-08-04T07:00:00Z"],"dc:description":["Physical and Mathematical Sciences","Chemistry and Biochemistry"],"dc:description.abstract":["Desorption electrospray ionization (DESI) is an ambient ionization technique for mass spectrometry. This solvent based desorption ion source has wide applicability in surface analysis with minimal sample preparation. Interest in improving detection limits, broadening applications, and increasing the spatial resolution for chemical imaging has led to studies of the DESI mechanism. An inverted microscope has been used to image interactions between the DESI spray and test analytes on a glass surface. Microscopic images recorded with millisecond time resolution have provided important insights into the processes governing analyte transport and desorption. These insights are the basis of a rivulet-based model for desorption that differs significantly from the widely-accepted momentum transfer model."],"dc:format":["application: pdf"],"dc:identifier":["https://scholarsarchive.byu.edu/etd/2826"],"dc:language":["English"],"dc:publisher":["Brigham Young University - Provo"],"dc:rights.license":["http://lib.byu.edu/about/copyright/"],"dc:source":["Brigham Young University - Provo"],"dc:subject":["DESI","Desorption Electrospray Ionization","Microscopic","Imaging","Real-time","Mechanism","Fluorescence","Absorption","Coating","Rivulets","Mass Spectrometry","Biochemistry","Chemistry"],"dc:title":["Characterization of the Desorption Electrospray Ionization Mechanism Using Microscopic Imaging of the Sample Surface"],"dc:type":["Dissertation"],"thesis:degree_name":["PhD"]},"updated_at":"2026-11-27T02:25:28Z"}