{"id":{"repo_id":"byu","oai_identifier":"oai:scholarsarchive.byu.edu:etd-4727"},"canonical_url":"https://search.ndltd.org/etd/byu/oai:scholarsarchive.byu.edu:etd-4727","repository":{"repo_id":"byu","name":"Brigham Young University","base_url":"https://scholarsarchive.byu.edu/do/oai/"},"display":{"title":"Maximization of Hydraulic Flow through Small Flexible Polymer Tubes by the Optimization of Tubing Stiffness and Wall Thickness","abstract":"As illness becomes increasingly more common in the United States and across the globe, the need for better and faster medical treatment is greater than ever. The purpose of this work is to evaluate advanced polymers and polymer composites that will provide for increased fluid flow while maintaining outer dimensional, stiffness, and burst resistance characteristics when compared to a currently used material. A polymer configuration consisting of a proprietary formulation that has a durometer approximately 10% higher than the current material with an outer wall thickness of approximately .020\" passed a series of tests involving tensile strength, stiffness, flexural fatigue resistance, vacuum lumen collapse resistance and hydraulic burst resistance. This material configuration passed the requirements for applicable test standards and had a tensile strength 13.4% less than the control group, was 52.7% stiffer, did not sustain any noticeable wear or defects during the flexural fatigue test, had a tensile strength 14.8% less that the control group during a post flex fatigue tensile test, did not burst when 150 psi was applied to it for 5 seconds, and is estimated to have a 43% higher flow rate capacity than the current material.","abstract_html":"As illness becomes increasingly more common in the United States and across the globe, the need for better and faster medical treatment is greater than ever. The purpose of this work is to evaluate advanced polymers and polymer composites that will provide for increased fluid flow while maintaining outer dimensional, stiffness, and burst resistance characteristics when compared to a currently used material. A polymer configuration consisting of a proprietary formulation that has a durometer approximately 10% higher than the current material with an outer wall thickness of approximately .020&quot; passed a series of tests involving tensile strength, stiffness, flexural fatigue resistance, vacuum lumen collapse resistance and hydraulic burst resistance. This material configuration passed the requirements for applicable test standards and had a tensile strength 13.4% less than the control group, was 52.7% stiffer, did not sustain any noticeable wear or defects during the flexural fatigue test, had a tensile strength 14.8% less that the control group during a post flex fatigue tensile test, did not burst when 150 psi was applied to it for 5 seconds, and is estimated to have a 43% higher flow rate capacity than the current material.","abstract_has_math":false,"creators":["Chipman, Christopher L."],"institution":"Brigham Young University - Provo","degree_name":"MS","degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2013,"date_issued":"2013-07-10T07:00:00Z","date_published":"2013-07-10T07:00:00Z","updated_at":"2026-11-27T02:25:52Z","subjects":["carbon nanotubes","central venous catheter","flow","glass beads","stiffness","tensile","Analytical, Diagnostic and Therapeutic Techniques and Equipment"],"languages":["English"],"rights":[],"rights_urls":["http://lib.byu.edu/about/copyright/"],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://scholarsarchive.byu.edu/etd/3728","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://scholarsarchive.byu.edu/etd/3728","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Abyu%3Aoai%3Ascholarsarchive.byu.edu%3Aetd-4727","prefix":"oai_dc"},"source_record":{"url":"https://scholarsarchive.byu.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Ascholarsarchive.byu.edu%3Aetd-4727","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Chipman, Christopher L."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2013-07-10T07:00:00Z"]},{"key":"dc:publisher","label":"Institution","values":["Brigham Young University - Provo"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["MS"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["carbon nanotubes","central venous catheter","flow","glass beads","stiffness","tensile","Analytical, Diagnostic and Therapeutic Techniques and Equipment"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights.license","label":"Dc Rights License","values":["http://lib.byu.edu/about/copyright/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://scholarsarchive.byu.edu/etd/3728"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Ira A. Fulton College of Engineering and Technology","Technology"]},{"key":"dc:description.abstract","label":"Abstract","values":["As illness becomes increasingly more common in the United States and across the globe, the need for better and faster medical treatment is greater than ever. The purpose of this work is to evaluate advanced polymers and polymer composites that will provide for increased fluid flow while maintaining outer dimensional, stiffness, and burst resistance characteristics when compared to a currently used material. A polymer configuration consisting of a proprietary formulation that has a durometer approximately 10% higher than the current material with an outer wall thickness of approximately .020\" passed a series of tests involving tensile strength, stiffness, flexural fatigue resistance, vacuum lumen collapse resistance and hydraulic burst resistance. This material configuration passed the requirements for applicable test standards and had a tensile strength 13.4% less than the control group, was 52.7% stiffer, did not sustain any noticeable wear or defects during the flexural fatigue test, had a tensile strength 14.8% less that the control group during a post flex fatigue tensile test, did not burst when 150 psi was applied to it for 5 seconds, and is estimated to have a 43% higher flow rate capacity than the current material."]},{"key":"dc:format","label":"Dc Format","values":["application: pdf"]},{"key":"dc:source","label":"Dc Source","values":["Brigham Young University - Provo"]},{"key":"dc:title","label":"Title","values":["Maximization of Hydraulic Flow through Small Flexible Polymer Tubes by the Optimization of Tubing Stiffness and Wall Thickness"]}]}],"canonical_facts":{"dc:creator":["Chipman, Christopher L."],"dc:date":["2013-07-10T07:00:00Z"],"dc:description":["Ira A. Fulton College of Engineering and Technology","Technology"],"dc:description.abstract":["As illness becomes increasingly more common in the United States and across the globe, the need for better and faster medical treatment is greater than ever. The purpose of this work is to evaluate advanced polymers and polymer composites that will provide for increased fluid flow while maintaining outer dimensional, stiffness, and burst resistance characteristics when compared to a currently used material. A polymer configuration consisting of a proprietary formulation that has a durometer approximately 10% higher than the current material with an outer wall thickness of approximately .020\" passed a series of tests involving tensile strength, stiffness, flexural fatigue resistance, vacuum lumen collapse resistance and hydraulic burst resistance. This material configuration passed the requirements for applicable test standards and had a tensile strength 13.4% less than the control group, was 52.7% stiffer, did not sustain any noticeable wear or defects during the flexural fatigue test, had a tensile strength 14.8% less that the control group during a post flex fatigue tensile test, did not burst when 150 psi was applied to it for 5 seconds, and is estimated to have a 43% higher flow rate capacity than the current material."],"dc:format":["application: pdf"],"dc:identifier":["https://scholarsarchive.byu.edu/etd/3728"],"dc:language":["English"],"dc:publisher":["Brigham Young University - Provo"],"dc:rights.license":["http://lib.byu.edu/about/copyright/"],"dc:source":["Brigham Young University - Provo"],"dc:subject":["carbon nanotubes","central venous catheter","flow","glass beads","stiffness","tensile","Analytical, Diagnostic and Therapeutic Techniques and Equipment"],"dc:title":["Maximization of Hydraulic Flow through Small Flexible Polymer Tubes by the Optimization of Tubing Stiffness and Wall Thickness"],"dc:type":["Thesis"],"thesis:degree_name":["MS"]},"updated_at":"2026-11-27T02:25:52Z"}