{"id":{"repo_id":"byu","oai_identifier":"oai:scholarsarchive.byu.edu:etd-4968"},"canonical_url":"https://search.ndltd.org/etd/byu/oai:scholarsarchive.byu.edu:etd-4968","repository":{"repo_id":"byu","name":"Brigham Young University","base_url":"https://scholarsarchive.byu.edu/do/oai/"},"display":{"title":"Desorption Electrospray Ionization Mass Spectrometry Imaging: Instrumentation, Optimization and Capabilities","abstract":"Desorption Electrospray Ionization Mass spectrometry Imaging (DESI-MSI) is an area of great interest and a promising tool in the field of chemical imaging. It is a powerful, label-free technique, which can determine, map and visualize different molecular compounds on a sample surface. The amount of information acquired in a single DESI-MSI experiment is enormous compared to other techniques, as it can simultaneously detect different compounds with their spatial distribution on the surface. The experiment can be used to produce two-dimensional and three-dimensional images. Chapter 2 focuses on the design and optimization of the setup for performing DESI-MS imaging on various substrates. The proposed setup was tested for its lateral spatial resolution. To provide proof-of-concept of the design, preliminary tests were performed to generate images from commercial thin layer chromatographic plates and photographic paper. Chapter 3 focuses on demonstrating the compatibility of novel microfabricated Thin Layer Chromatography plates (M-TLC plates) for detection with DESI-MSI.","abstract_html":"Desorption Electrospray Ionization Mass spectrometry Imaging (DESI-MSI) is an area of great interest and a promising tool in the field of chemical imaging. It is a powerful, label-free technique, which can determine, map and visualize different molecular compounds on a sample surface. The amount of information acquired in a single DESI-MSI experiment is enormous compared to other techniques, as it can simultaneously detect different compounds with their spatial distribution on the surface. The experiment can be used to produce two-dimensional and three-dimensional images. Chapter 2 focuses on the design and optimization of the setup for performing DESI-MS imaging on various substrates. The proposed setup was tested for its lateral spatial resolution. To provide proof-of-concept of the design, preliminary tests were performed to generate images from commercial thin layer chromatographic plates and photographic paper. Chapter 3 focuses on demonstrating the compatibility of novel microfabricated Thin Layer Chromatography plates (M-TLC plates) for detection with DESI-MSI.","abstract_has_math":false,"creators":["Dhunna, Manan"],"institution":"Brigham Young University - Provo","degree_name":"MS","degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2014,"date_issued":"2014-03-13T07:00:00Z","date_published":"2014-03-13T07:00:00Z","updated_at":"2026-11-27T02:25:52Z","subjects":["Desorption Electrospray Ionization","DESI","Desorption electrospray Mass Spectrometry Imaging","DESI-MSI","Microfabricated Thin Layer Chromatography","M-TLC","Ambient Ionization Mass Spectrometry","Biochemistry","Chemistry"],"languages":["English"],"rights":[],"rights_urls":["http://lib.byu.edu/about/copyright/"],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://scholarsarchive.byu.edu/etd/3969","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://scholarsarchive.byu.edu/etd/3969","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Abyu%3Aoai%3Ascholarsarchive.byu.edu%3Aetd-4968","prefix":"oai_dc"},"source_record":{"url":"https://scholarsarchive.byu.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Ascholarsarchive.byu.edu%3Aetd-4968","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Dhunna, Manan"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2014-03-13T07:00:00Z"]},{"key":"dc:publisher","label":"Institution","values":["Brigham Young University - Provo"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["MS"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Desorption Electrospray Ionization","DESI","Desorption electrospray Mass Spectrometry Imaging","DESI-MSI","Microfabricated Thin Layer Chromatography","M-TLC","Ambient Ionization Mass Spectrometry","Biochemistry","Chemistry"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights.license","label":"Dc Rights License","values":["http://lib.byu.edu/about/copyright/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://scholarsarchive.byu.edu/etd/3969"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Physical and Mathematical Sciences","Chemistry and Biochemistry"]},{"key":"dc:description.abstract","label":"Abstract","values":["Desorption Electrospray Ionization Mass spectrometry Imaging (DESI-MSI) is an area of great interest and a promising tool in the field of chemical imaging. It is a powerful, label-free technique, which can determine, map and visualize different molecular compounds on a sample surface. The amount of information acquired in a single DESI-MSI experiment is enormous compared to other techniques, as it can simultaneously detect different compounds with their spatial distribution on the surface. The experiment can be used to produce two-dimensional and three-dimensional images. Chapter 2 focuses on the design and optimization of the setup for performing DESI-MS imaging on various substrates. The proposed setup was tested for its lateral spatial resolution. To provide proof-of-concept of the design, preliminary tests were performed to generate images from commercial thin layer chromatographic plates and photographic paper. Chapter 3 focuses on demonstrating the compatibility of novel microfabricated Thin Layer Chromatography plates (M-TLC plates) for detection with DESI-MSI."]},{"key":"dc:format","label":"Dc Format","values":["application: pdf"]},{"key":"dc:source","label":"Dc Source","values":["Brigham Young University - Provo"]},{"key":"dc:title","label":"Title","values":["Desorption Electrospray Ionization Mass Spectrometry Imaging: Instrumentation, Optimization and Capabilities"]}]}],"canonical_facts":{"dc:creator":["Dhunna, Manan"],"dc:date":["2014-03-13T07:00:00Z"],"dc:description":["Physical and Mathematical Sciences","Chemistry and Biochemistry"],"dc:description.abstract":["Desorption Electrospray Ionization Mass spectrometry Imaging (DESI-MSI) is an area of great interest and a promising tool in the field of chemical imaging. It is a powerful, label-free technique, which can determine, map and visualize different molecular compounds on a sample surface. The amount of information acquired in a single DESI-MSI experiment is enormous compared to other techniques, as it can simultaneously detect different compounds with their spatial distribution on the surface. The experiment can be used to produce two-dimensional and three-dimensional images. Chapter 2 focuses on the design and optimization of the setup for performing DESI-MS imaging on various substrates. The proposed setup was tested for its lateral spatial resolution. To provide proof-of-concept of the design, preliminary tests were performed to generate images from commercial thin layer chromatographic plates and photographic paper. Chapter 3 focuses on demonstrating the compatibility of novel microfabricated Thin Layer Chromatography plates (M-TLC plates) for detection with DESI-MSI."],"dc:format":["application: pdf"],"dc:identifier":["https://scholarsarchive.byu.edu/etd/3969"],"dc:language":["English"],"dc:publisher":["Brigham Young University - Provo"],"dc:rights.license":["http://lib.byu.edu/about/copyright/"],"dc:source":["Brigham Young University - Provo"],"dc:subject":["Desorption Electrospray Ionization","DESI","Desorption electrospray Mass Spectrometry Imaging","DESI-MSI","Microfabricated Thin Layer Chromatography","M-TLC","Ambient Ionization Mass Spectrometry","Biochemistry","Chemistry"],"dc:title":["Desorption Electrospray Ionization Mass Spectrometry Imaging: Instrumentation, Optimization and Capabilities"],"dc:type":["Thesis"],"thesis:degree_name":["MS"]},"updated_at":"2026-11-27T02:25:52Z"}