{"id":{"repo_id":"byu","oai_identifier":"oai:scholarsarchive.byu.edu:etd-5260"},"canonical_url":"https://search.ndltd.org/etd/byu/oai:scholarsarchive.byu.edu:etd-5260","repository":{"repo_id":"byu","name":"Brigham Young University","base_url":"https://scholarsarchive.byu.edu/do/oai/"},"display":{"title":"Dynamic Nanochannels for Biosensing Applications","abstract":"Inexpensive label-free detection of biomarker panels in serum could revolutionize earlycancer diagnosis and treatment. Such detection capabilities may be possible with dynamicnanochannels in conjunction with electrical impedance measurement. In Dr. Greg Nordin's lab I designed, fabricated and tested several iterations of these sensors with polydimethyl-siloxane microfluidics. The final design yielded a dynamic nanochannel array sensor thatshowed a 140% impedance change when exposed to 14µM bovine serum albumin in phos-phate buffered saline. For the geometry and noise limits of the tested device, simulationsindicated that a minimum detectable concentration of 20pM with specifically bound strep-tavidin should be possible. However, the polydimethylsiloxane approach is also shown to beproblematic in meeting the trade-offs required for a practical device. Consequently, alter-native materials and designs are suggested to reduce the minimum detectable concentrationto the high femtomolar range, which would be attractive for detection of many medicalbiomarkers.","abstract_html":"Inexpensive label-free detection of biomarker panels in serum could revolutionize earlycancer diagnosis and treatment. Such detection capabilities may be possible with dynamicnanochannels in conjunction with electrical impedance measurement. In Dr. Greg Nordin&#x27;s lab I designed, fabricated and tested several iterations of these sensors with polydimethyl-siloxane microfluidics. The final design yielded a dynamic nanochannel array sensor thatshowed a 140% impedance change when exposed to 14µM bovine serum albumin in phos-phate buffered saline. For the geometry and noise limits of the tested device, simulationsindicated that a minimum detectable concentration of 20pM with specifically bound strep-tavidin should be possible. However, the polydimethylsiloxane approach is also shown to beproblematic in meeting the trade-offs required for a practical device. Consequently, alter-native materials and designs are suggested to reduce the minimum detectable concentrationto the high femtomolar range, which would be attractive for detection of many medicalbiomarkers.","abstract_has_math":false,"creators":["Oxborrow, Joseph B"],"institution":"Brigham Young University - Provo","degree_name":"MS","degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2013,"date_issued":"2013-11-01T07:00:00Z","date_published":"2013-11-01T07:00:00Z","updated_at":"2026-11-27T02:25:58Z","subjects":["Proteomics","biomarkers","nanochannels","impedance sensing","Electrical and Computer Engineering"],"languages":["english"],"rights":[],"rights_urls":["http://lib.byu.edu/about/copyright/"],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://scholarsarchive.byu.edu/etd/4261","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://scholarsarchive.byu.edu/etd/4261","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Abyu%3Aoai%3Ascholarsarchive.byu.edu%3Aetd-5260","prefix":"oai_dc"},"source_record":{"url":"https://scholarsarchive.byu.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Ascholarsarchive.byu.edu%3Aetd-5260","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Oxborrow, Joseph B"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2013-11-01T07:00:00Z"]},{"key":"dc:publisher","label":"Institution","values":["Brigham Young University - Provo"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["MS"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Proteomics","biomarkers","nanochannels","impedance sensing","Electrical and Computer Engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["english"]},{"key":"dc:rights.license","label":"Dc Rights License","values":["http://lib.byu.edu/about/copyright/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://scholarsarchive.byu.edu/etd/4261"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Ira A. Fulton College of Engineering and Technology","Electrical and Computer Engineering"]},{"key":"dc:description.abstract","label":"Abstract","values":["Inexpensive label-free detection of biomarker panels in serum could revolutionize earlycancer diagnosis and treatment. Such detection capabilities may be possible with dynamicnanochannels in conjunction with electrical impedance measurement. In Dr. Greg Nordin's lab I designed, fabricated and tested several iterations of these sensors with polydimethyl-siloxane microfluidics. The final design yielded a dynamic nanochannel array sensor thatshowed a 140% impedance change when exposed to 14µM bovine serum albumin in phos-phate buffered saline. For the geometry and noise limits of the tested device, simulationsindicated that a minimum detectable concentration of 20pM with specifically bound strep-tavidin should be possible. However, the polydimethylsiloxane approach is also shown to beproblematic in meeting the trade-offs required for a practical device. Consequently, alter-native materials and designs are suggested to reduce the minimum detectable concentrationto the high femtomolar range, which would be attractive for detection of many medicalbiomarkers."]},{"key":"dc:format","label":"Dc Format","values":["application:pdf"]},{"key":"dc:source","label":"Dc Source","values":["Brigham Young University - Provo"]},{"key":"dc:title","label":"Title","values":["Dynamic Nanochannels for Biosensing Applications"]}]}],"canonical_facts":{"dc:creator":["Oxborrow, Joseph B"],"dc:date":["2013-11-01T07:00:00Z"],"dc:description":["Ira A. Fulton College of Engineering and Technology","Electrical and Computer Engineering"],"dc:description.abstract":["Inexpensive label-free detection of biomarker panels in serum could revolutionize earlycancer diagnosis and treatment. Such detection capabilities may be possible with dynamicnanochannels in conjunction with electrical impedance measurement. In Dr. Greg Nordin's lab I designed, fabricated and tested several iterations of these sensors with polydimethyl-siloxane microfluidics. The final design yielded a dynamic nanochannel array sensor thatshowed a 140% impedance change when exposed to 14µM bovine serum albumin in phos-phate buffered saline. For the geometry and noise limits of the tested device, simulationsindicated that a minimum detectable concentration of 20pM with specifically bound strep-tavidin should be possible. However, the polydimethylsiloxane approach is also shown to beproblematic in meeting the trade-offs required for a practical device. Consequently, alter-native materials and designs are suggested to reduce the minimum detectable concentrationto the high femtomolar range, which would be attractive for detection of many medicalbiomarkers."],"dc:format":["application:pdf"],"dc:identifier":["https://scholarsarchive.byu.edu/etd/4261"],"dc:language":["english"],"dc:publisher":["Brigham Young University - Provo"],"dc:rights.license":["http://lib.byu.edu/about/copyright/"],"dc:source":["Brigham Young University - Provo"],"dc:subject":["Proteomics","biomarkers","nanochannels","impedance sensing","Electrical and Computer Engineering"],"dc:title":["Dynamic Nanochannels for Biosensing Applications"],"dc:type":["Thesis"],"thesis:degree_name":["MS"]},"updated_at":"2026-11-27T02:25:58Z"}