{"id":{"repo_id":"byu","oai_identifier":"oai:scholarsarchive.byu.edu:etd-7236"},"canonical_url":"https://search.ndltd.org/etd/byu/oai:scholarsarchive.byu.edu:etd-7236","repository":{"repo_id":"byu","name":"Brigham Young University","base_url":"https://scholarsarchive.byu.edu/do/oai/"},"display":{"title":"Effects of Tethering Placement and Linker Variations on Antibody Stability on Surfaces","abstract":"An antibody microarray consists of antibody bound to a surface. Antibody microarrays have great potential in many fields, particularly as a tool to detect antigens. Unfortunately, antibodies suffer from poor performance. A greater understanding of how antibodies interact with surfaces would improve microarray design and performance, but experimental methods fall short of being able to observe these interactions. Therefore molecular simulation has emerged as the primary method to study protein/surface interactions.The simulations here were coarse grain simulations performed using the model of Karanicolas and Brooks. Additionally, an advanced surface model was used that allows for different surface chemistries. PyMBAR analysis was used to find heat capacities and determine relative stabilities of different linkers and tethering sites for the antibody/surface system.The actual work looked at how 24 different tethering sites affect antibody stability on two different surfaces and examined nine linkers varying in length and rigidity. Ultimately the findings were that antibody stability is a function of tethering position when tethered to a hydrophobic surface, but not when tethered to a hydrophilic surface. Furthermore, the length and rigidity of the linkers do not have a significant impact on stability.","abstract_html":"An antibody microarray consists of antibody bound to a surface. Antibody microarrays have great potential in many fields, particularly as a tool to detect antigens. Unfortunately, antibodies suffer from poor performance. A greater understanding of how antibodies interact with surfaces would improve microarray design and performance, but experimental methods fall short of being able to observe these interactions. Therefore molecular simulation has emerged as the primary method to study protein/surface interactions.The simulations here were coarse grain simulations performed using the model of Karanicolas and Brooks. Additionally, an advanced surface model was used that allows for different surface chemistries. PyMBAR analysis was used to find heat capacities and determine relative stabilities of different linkers and tethering sites for the antibody/surface system.The actual work looked at how 24 different tethering sites affect antibody stability on two different surfaces and examined nine linkers varying in length and rigidity. Ultimately the findings were that antibody stability is a function of tethering position when tethered to a hydrophobic surface, but not when tethered to a hydrophilic surface. Furthermore, the length and rigidity of the linkers do not have a significant impact on stability.","abstract_has_math":false,"creators":["Grawe, Rebecca Ellen"],"institution":"Brigham Young University","degree_name":"MS","degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2016,"date_issued":"2016-12-01T08:00:00Z","date_published":"2016-12-01T08:00:00Z","updated_at":"2026-11-27T02:26:21Z","subjects":["microarrays","antibodies","coarse-grain simulations","Chemical Engineering"],"languages":["english"],"rights":[],"rights_urls":["http://lib.byu.edu/about/copyright/"],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://scholarsarchive.byu.edu/etd/6236","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://scholarsarchive.byu.edu/etd/6236","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Abyu%3Aoai%3Ascholarsarchive.byu.edu%3Aetd-7236","prefix":"oai_dc"},"source_record":{"url":"https://scholarsarchive.byu.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Ascholarsarchive.byu.edu%3Aetd-7236","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Grawe, Rebecca Ellen"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2016-12-01T08:00:00Z"]},{"key":"dc:publisher","label":"Institution","values":["Brigham Young University"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["MS"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["microarrays","antibodies","coarse-grain simulations","Chemical Engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["english"]},{"key":"dc:rights.license","label":"Dc Rights License","values":["http://lib.byu.edu/about/copyright/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://scholarsarchive.byu.edu/etd/6236"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Ira A. Fulton College of Engineering and Technology","Chemical Engineering"]},{"key":"dc:description.abstract","label":"Abstract","values":["An antibody microarray consists of antibody bound to a surface. Antibody microarrays have great potential in many fields, particularly as a tool to detect antigens. Unfortunately, antibodies suffer from poor performance. A greater understanding of how antibodies interact with surfaces would improve microarray design and performance, but experimental methods fall short of being able to observe these interactions. Therefore molecular simulation has emerged as the primary method to study protein/surface interactions.The simulations here were coarse grain simulations performed using the model of Karanicolas and Brooks. Additionally, an advanced surface model was used that allows for different surface chemistries. PyMBAR analysis was used to find heat capacities and determine relative stabilities of different linkers and tethering sites for the antibody/surface system.The actual work looked at how 24 different tethering sites affect antibody stability on two different surfaces and examined nine linkers varying in length and rigidity. Ultimately the findings were that antibody stability is a function of tethering position when tethered to a hydrophobic surface, but not when tethered to a hydrophilic surface. Furthermore, the length and rigidity of the linkers do not have a significant impact on stability."]},{"key":"dc:format","label":"Dc Format","values":["application:pdf"]},{"key":"dc:source","label":"Dc Source","values":["Brigham Young University"]},{"key":"dc:title","label":"Title","values":["Effects of Tethering Placement and Linker Variations on Antibody Stability on Surfaces"]}]}],"canonical_facts":{"dc:creator":["Grawe, Rebecca Ellen"],"dc:date":["2016-12-01T08:00:00Z"],"dc:description":["Ira A. Fulton College of Engineering and Technology","Chemical Engineering"],"dc:description.abstract":["An antibody microarray consists of antibody bound to a surface. Antibody microarrays have great potential in many fields, particularly as a tool to detect antigens. Unfortunately, antibodies suffer from poor performance. A greater understanding of how antibodies interact with surfaces would improve microarray design and performance, but experimental methods fall short of being able to observe these interactions. Therefore molecular simulation has emerged as the primary method to study protein/surface interactions.The simulations here were coarse grain simulations performed using the model of Karanicolas and Brooks. Additionally, an advanced surface model was used that allows for different surface chemistries. PyMBAR analysis was used to find heat capacities and determine relative stabilities of different linkers and tethering sites for the antibody/surface system.The actual work looked at how 24 different tethering sites affect antibody stability on two different surfaces and examined nine linkers varying in length and rigidity. Ultimately the findings were that antibody stability is a function of tethering position when tethered to a hydrophobic surface, but not when tethered to a hydrophilic surface. Furthermore, the length and rigidity of the linkers do not have a significant impact on stability."],"dc:format":["application:pdf"],"dc:identifier":["https://scholarsarchive.byu.edu/etd/6236"],"dc:language":["english"],"dc:publisher":["Brigham Young University"],"dc:rights.license":["http://lib.byu.edu/about/copyright/"],"dc:source":["Brigham Young University"],"dc:subject":["microarrays","antibodies","coarse-grain simulations","Chemical Engineering"],"dc:title":["Effects of Tethering Placement and Linker Variations on Antibody Stability on Surfaces"],"dc:type":["Thesis"],"thesis:degree_name":["MS"]},"updated_at":"2026-11-27T02:26:21Z"}