{"id":{"repo_id":"byu","oai_identifier":"oai:scholarsarchive.byu.edu:etd-9115"},"canonical_url":"https://search.ndltd.org/etd/byu/oai:scholarsarchive.byu.edu:etd-9115","repository":{"repo_id":"byu","name":"Brigham Young University","base_url":"https://scholarsarchive.byu.edu/do/oai/"},"display":{"title":"Studies of Dislocation Density Quantification Via Cross-Correlation EBSD","abstract":"One conventional method for studying dislocations uses the Transmission Electron Microscope (TEM), a complex and expensive piece of equipment which requires extensive specimen preparation in order to thin the specimens to electron transparent thickness. Newer High Resolution Electron Backscatter Diffraction (HREBSD) methods of determining geometrically necessary dislocation content via cross-correlation promise to be able to produce estimates of the dislocation density of the sample over a larger area with considerably less preparation time and using a much more accessible instrument. However, the accuracy of the new EBSD technique needs more experimental verification, including consideration of possible changes in the specimen dislocation density due to the different preparation methods. By comparing EBSD and TEM dislocation measurements of Electron Transparent platinum specimens prepared using the Focused Ion Beam (FIB), along with EBSD dislocations measurements of specimens prepared by both FIB and mechanical polishing techniques, this paper seeks to verify the accuracy of the new method and identify any changes in the specimens’ apparent dislocation density caused by the different preparation processes.","abstract_html":"One conventional method for studying dislocations uses the Transmission Electron Microscope (TEM), a complex and expensive piece of equipment which requires extensive specimen preparation in order to thin the specimens to electron transparent thickness. Newer High Resolution Electron Backscatter Diffraction (HREBSD) methods of determining geometrically necessary dislocation content via cross-correlation promise to be able to produce estimates of the dislocation density of the sample over a larger area with considerably less preparation time and using a much more accessible instrument. However, the accuracy of the new EBSD technique needs more experimental verification, including consideration of possible changes in the specimen dislocation density due to the different preparation methods. By comparing EBSD and TEM dislocation measurements of Electron Transparent platinum specimens prepared using the Focused Ion Beam (FIB), along with EBSD dislocations measurements of specimens prepared by both FIB and mechanical polishing techniques, this paper seeks to verify the accuracy of the new method and identify any changes in the specimens’ apparent dislocation density caused by the different preparation processes.","abstract_has_math":false,"creators":["Friedbaum, Samuel Searle"],"institution":null,"degree_name":"MS","degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2019,"date_issued":"2019-08-01T07:00:00Z","date_published":"2019-08-01T07:00:00Z","updated_at":"2026-11-27T02:26:32Z","subjects":["scanning electron microscopy","electron backscatter diffraction","transmission electron microscopy","dislocations","focused ion beam","platinum","Engineering","Mechanical Engineering"],"languages":["English"],"rights":[],"rights_urls":["http://lib.byu.edu/about/copyright/"],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://scholarsarchive.byu.edu/etd/8115","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://scholarsarchive.byu.edu/etd/8115","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Abyu%3Aoai%3Ascholarsarchive.byu.edu%3Aetd-9115","prefix":"oai_dc"},"source_record":{"url":"https://scholarsarchive.byu.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Ascholarsarchive.byu.edu%3Aetd-9115","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Friedbaum, Samuel Searle"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2019-08-01T07:00:00Z"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["MS"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["scanning electron microscopy","electron backscatter diffraction","transmission electron microscopy","dislocations","focused ion beam","platinum","Engineering","Mechanical Engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights.license","label":"Dc Rights License","values":["http://lib.byu.edu/about/copyright/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://scholarsarchive.byu.edu/etd/8115"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Ira A. Fulton College of Engineering and Technology","Mechanical Engineering"]},{"key":"dc:description.abstract","label":"Abstract","values":["One conventional method for studying dislocations uses the Transmission Electron Microscope (TEM), a complex and expensive piece of equipment which requires extensive specimen preparation in order to thin the specimens to electron transparent thickness. Newer High Resolution Electron Backscatter Diffraction (HREBSD) methods of determining geometrically necessary dislocation content via cross-correlation promise to be able to produce estimates of the dislocation density of the sample over a larger area with considerably less preparation time and using a much more accessible instrument. However, the accuracy of the new EBSD technique needs more experimental verification, including consideration of possible changes in the specimen dislocation density due to the different preparation methods. By comparing EBSD and TEM dislocation measurements of Electron Transparent platinum specimens prepared using the Focused Ion Beam (FIB), along with EBSD dislocations measurements of specimens prepared by both FIB and mechanical polishing techniques, this paper seeks to verify the accuracy of the new method and identify any changes in the specimens’ apparent dislocation density caused by the different preparation processes."]},{"key":"dc:format","label":"Dc Format","values":["application:pdf"]},{"key":"dc:source","label":"Dc Source","values":["Brigham Young University"]},{"key":"dc:title","label":"Title","values":["Studies of Dislocation Density Quantification Via Cross-Correlation EBSD"]}]}],"canonical_facts":{"dc:creator":["Friedbaum, Samuel Searle"],"dc:date":["2019-08-01T07:00:00Z"],"dc:description":["Ira A. Fulton College of Engineering and Technology","Mechanical Engineering"],"dc:description.abstract":["One conventional method for studying dislocations uses the Transmission Electron Microscope (TEM), a complex and expensive piece of equipment which requires extensive specimen preparation in order to thin the specimens to electron transparent thickness. Newer High Resolution Electron Backscatter Diffraction (HREBSD) methods of determining geometrically necessary dislocation content via cross-correlation promise to be able to produce estimates of the dislocation density of the sample over a larger area with considerably less preparation time and using a much more accessible instrument. However, the accuracy of the new EBSD technique needs more experimental verification, including consideration of possible changes in the specimen dislocation density due to the different preparation methods. By comparing EBSD and TEM dislocation measurements of Electron Transparent platinum specimens prepared using the Focused Ion Beam (FIB), along with EBSD dislocations measurements of specimens prepared by both FIB and mechanical polishing techniques, this paper seeks to verify the accuracy of the new method and identify any changes in the specimens’ apparent dislocation density caused by the different preparation processes."],"dc:format":["application:pdf"],"dc:identifier":["https://scholarsarchive.byu.edu/etd/8115"],"dc:language":["English"],"dc:rights.license":["http://lib.byu.edu/about/copyright/"],"dc:source":["Brigham Young University"],"dc:subject":["scanning electron microscopy","electron backscatter diffraction","transmission electron microscopy","dislocations","focused ion beam","platinum","Engineering","Mechanical Engineering"],"dc:title":["Studies of Dislocation Density Quantification Via Cross-Correlation EBSD"],"dc:type":["Thesis"],"thesis:degree_name":["MS"]},"updated_at":"2026-11-27T02:26:32Z"}