{"id":{"repo_id":"byu","oai_identifier":"oai:scholarsarchive.byu.edu:etd-9317"},"canonical_url":"https://search.ndltd.org/etd/byu/oai:scholarsarchive.byu.edu:etd-9317","repository":{"repo_id":"byu","name":"Brigham Young University","base_url":"https://scholarsarchive.byu.edu/do/oai/"},"display":{"title":"An investigation of column efficiency and the relationship to liquid phase distribution on ultra-low loaded glass bead gas chromatographic columns","abstract":"Studies have been made of column efficiencies, extra-column effects, the liquid phase mass transfer term (C_l), and liquid phase distribution at ultra-low liquid loadings on glass bead gas-liquid chromatographic columns. The advantages of using lightly loaded columns are described in detail along with a critical evaluation of the limitations of this liquid phase reduction ad infinitum. Theories have been presented by Giddings^22,23,25,30,32 which predict the mass transfer term (C_l) as a function of two extreme liquid phase distributions. The first equation assumes 100% \"capillary\" liquid held at the glass bead contact points and represents a very inefficient column. This prediction is known to be valid for normal loaded columns in the 1.0 to 0.1 liquid percentage range^35,48. The second equation assumes a uniform liquid \"adsorption\" film around the glass bead which represents a very efficient condition. This equation has never been experimentally verified, but Hawkes^48 and Giddings^35 suggest that this condition is approached when the liquid phase is reduced and that a uniform film exists at loadings less than approximately 0.04%. The results of this research show that although a uniform film is approached with liquid load reduction, it is never reached, even at loadings as low as 0.004%. Data show that the capillary liquid assumption is valid for glass bead columns with liquid loadings greater than 0.05%, but fails to predict the proper efficiency term at the lower loadings. Two important transitions occur at about 0.03% liquid loading: (1) C_l ceases to decrease significantly with a liquid load reduction, and (2) C_l ceases to be the predominant (plate height controlling) efficiency parameter. Reductions below 0.03% do little to improve column efficiency and may cause adverse effects such as decreased resolution, increased adsorption, and a shorter column life. Data collected before and after some apparatus and procedure changes indicate the importance of minimizing extraneous peak broadening sources. It is suggested that a large amount of the literature is in error because of apathy in this area. The results suggest that a reduction in liquid load is an excellent method of increasing the column efficiency and reducing the analysis (sample retention) time.","abstract_html":"Studies have been made of column efficiencies, extra-column effects, the liquid phase mass transfer term (C_l), and liquid phase distribution at ultra-low liquid loadings on glass bead gas-liquid chromatographic columns. The advantages of using lightly loaded columns are described in detail along with a critical evaluation of the limitations of this liquid phase reduction ad infinitum. Theories have been presented by Giddings^22,23,25,30,32 which predict the mass transfer term (C_l) as a function of two extreme liquid phase distributions. The first equation assumes 100% &quot;capillary&quot; liquid held at the glass bead contact points and represents a very inefficient column. This prediction is known to be valid for normal loaded columns in the 1.0 to 0.1 liquid percentage range^35,48. The second equation assumes a uniform liquid &quot;adsorption&quot; film around the glass bead which represents a very efficient condition. This equation has never been experimentally verified, but Hawkes^48 and Giddings^35 suggest that this condition is approached when the liquid phase is reduced and that a uniform film exists at loadings less than approximately 0.04%. The results of this research show that although a uniform film is approached with liquid load reduction, it is never reached, even at loadings as low as 0.004%. Data show that the capillary liquid assumption is valid for glass bead columns with liquid loadings greater than 0.05%, but fails to predict the proper efficiency term at the lower loadings. Two important transitions occur at about 0.03% liquid loading: (1) C_l ceases to decrease significantly with a liquid load reduction, and (2) C_l ceases to be the predominant (plate height controlling) efficiency parameter. Reductions below 0.03% do little to improve column efficiency and may cause adverse effects such as decreased resolution, increased adsorption, and a shorter column life. Data collected before and after some apparatus and procedure changes indicate the importance of minimizing extraneous peak broadening sources. It is suggested that a large amount of the literature is in error because of apathy in this area. The results suggest that a reduction in liquid load is an excellent method of increasing the column efficiency and reducing the analysis (sample retention) time.","abstract_has_math":false,"creators":["Nyberg, Donald G."],"institution":null,"degree_name":"MS","degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1968,"date_issued":"1968-05-01T07:00:00Z","date_published":"1968-05-01T07:00:00Z","updated_at":"2026-11-27T02:26:32Z","subjects":["Gas chromatography","Chemistry"],"languages":["English"],"rights":[],"rights_urls":["http://lib.byu.edu/about/copyright/"],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://scholarsarchive.byu.edu/etd/8317","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://scholarsarchive.byu.edu/etd/8317","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Abyu%3Aoai%3Ascholarsarchive.byu.edu%3Aetd-9317","prefix":"oai_dc"},"source_record":{"url":"https://scholarsarchive.byu.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Ascholarsarchive.byu.edu%3Aetd-9317","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Nyberg, Donald G."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["1968-05-01T07:00:00Z"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["MS"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Gas chromatography","Chemistry"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English"]},{"key":"dc:rights.license","label":"Dc Rights License","values":["http://lib.byu.edu/about/copyright/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://scholarsarchive.byu.edu/etd/8317"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Physical and Mathematical Sciences","Chemistry and Biochemistry"]},{"key":"dc:description.abstract","label":"Abstract","values":["Studies have been made of column efficiencies, extra-column effects, the liquid phase mass transfer term (C_l), and liquid phase distribution at ultra-low liquid loadings on glass bead gas-liquid chromatographic columns. The advantages of using lightly loaded columns are described in detail along with a critical evaluation of the limitations of this liquid phase reduction ad infinitum. Theories have been presented by Giddings^22,23,25,30,32 which predict the mass transfer term (C_l) as a function of two extreme liquid phase distributions. The first equation assumes 100% \"capillary\" liquid held at the glass bead contact points and represents a very inefficient column. This prediction is known to be valid for normal loaded columns in the 1.0 to 0.1 liquid percentage range^35,48. The second equation assumes a uniform liquid \"adsorption\" film around the glass bead which represents a very efficient condition. This equation has never been experimentally verified, but Hawkes^48 and Giddings^35 suggest that this condition is approached when the liquid phase is reduced and that a uniform film exists at loadings less than approximately 0.04%. The results of this research show that although a uniform film is approached with liquid load reduction, it is never reached, even at loadings as low as 0.004%. Data show that the capillary liquid assumption is valid for glass bead columns with liquid loadings greater than 0.05%, but fails to predict the proper efficiency term at the lower loadings. Two important transitions occur at about 0.03% liquid loading: (1) C_l ceases to decrease significantly with a liquid load reduction, and (2) C_l ceases to be the predominant (plate height controlling) efficiency parameter. Reductions below 0.03% do little to improve column efficiency and may cause adverse effects such as decreased resolution, increased adsorption, and a shorter column life. Data collected before and after some apparatus and procedure changes indicate the importance of minimizing extraneous peak broadening sources. It is suggested that a large amount of the literature is in error because of apathy in this area. The results suggest that a reduction in liquid load is an excellent method of increasing the column efficiency and reducing the analysis (sample retention) time."]},{"key":"dc:format","label":"Dc Format","values":["application:pdf"]},{"key":"dc:title","label":"Title","values":["An investigation of column efficiency and the relationship to liquid phase distribution on ultra-low loaded glass bead gas chromatographic columns"]}]}],"canonical_facts":{"dc:creator":["Nyberg, Donald G."],"dc:date":["1968-05-01T07:00:00Z"],"dc:description":["Physical and Mathematical Sciences","Chemistry and Biochemistry"],"dc:description.abstract":["Studies have been made of column efficiencies, extra-column effects, the liquid phase mass transfer term (C_l), and liquid phase distribution at ultra-low liquid loadings on glass bead gas-liquid chromatographic columns. The advantages of using lightly loaded columns are described in detail along with a critical evaluation of the limitations of this liquid phase reduction ad infinitum. Theories have been presented by Giddings^22,23,25,30,32 which predict the mass transfer term (C_l) as a function of two extreme liquid phase distributions. The first equation assumes 100% \"capillary\" liquid held at the glass bead contact points and represents a very inefficient column. This prediction is known to be valid for normal loaded columns in the 1.0 to 0.1 liquid percentage range^35,48. The second equation assumes a uniform liquid \"adsorption\" film around the glass bead which represents a very efficient condition. This equation has never been experimentally verified, but Hawkes^48 and Giddings^35 suggest that this condition is approached when the liquid phase is reduced and that a uniform film exists at loadings less than approximately 0.04%. The results of this research show that although a uniform film is approached with liquid load reduction, it is never reached, even at loadings as low as 0.004%. Data show that the capillary liquid assumption is valid for glass bead columns with liquid loadings greater than 0.05%, but fails to predict the proper efficiency term at the lower loadings. Two important transitions occur at about 0.03% liquid loading: (1) C_l ceases to decrease significantly with a liquid load reduction, and (2) C_l ceases to be the predominant (plate height controlling) efficiency parameter. Reductions below 0.03% do little to improve column efficiency and may cause adverse effects such as decreased resolution, increased adsorption, and a shorter column life. Data collected before and after some apparatus and procedure changes indicate the importance of minimizing extraneous peak broadening sources. It is suggested that a large amount of the literature is in error because of apathy in this area. The results suggest that a reduction in liquid load is an excellent method of increasing the column efficiency and reducing the analysis (sample retention) time."],"dc:format":["application:pdf"],"dc:identifier":["https://scholarsarchive.byu.edu/etd/8317"],"dc:language":["English"],"dc:rights.license":["http://lib.byu.edu/about/copyright/"],"dc:subject":["Gas chromatography","Chemistry"],"dc:title":["An investigation of column efficiency and the relationship to liquid phase distribution on ultra-low loaded glass bead gas chromatographic columns"],"dc:type":["Thesis"],"thesis:degree_name":["MS"]},"updated_at":"2026-11-27T02:26:32Z"}