{"id":{"repo_id":"calgary","oai_identifier":"oai:ucalgary.scholaris.ca:11023/100"},"canonical_url":"https://search.ndltd.org/etd/calgary/oai:ucalgary.scholaris.ca:11023/100","repository":{"repo_id":"calgary","name":"University of Calgary","base_url":"https://ucalgary.scholaris.ca/server/oai/request"},"display":{"title":"Total Knee Replacements: Component Design, Pain Prevention and Research Techniques","abstract":"Total knee arthroplasty is a surgical procedure in which the knee is resurfaced with implants to relieve pain. This thesis presents computed tomography and radiography methods to determine the relative position (kinematics) for the patellofemoral and tibiofemoral joints in vivo for a full range of motion, as well as parameters related to surgical technique. These methods were used to compare: (1) subjects with gender-specific (GS) versus traditional implant designs, (2) symptomatic versus asymptomatic subjects, and (3) static versus dynamic kinematics. Quality of life (QOL) was also measured. GS implants only had a small but significant difference in patellofemoral translation in early flexion; no other differences were found for the kinematics or QOL. For all symptomatic subjects, differences in kinematics or surgical parameters were found, suggesting the cause for the subject’s postoperative pain. Static and dynamic kinematics were comparable in all but one case, where internal/external tibial rotation differed.","abstract_html":"Total knee arthroplasty is a surgical procedure in which the knee is resurfaced with implants to relieve pain. This thesis presents computed tomography and radiography methods to determine the relative position (kinematics) for the patellofemoral and tibiofemoral joints in vivo for a full range of motion, as well as parameters related to surgical technique. These methods were used to compare: (1) subjects with gender-specific (GS) versus traditional implant designs, (2) symptomatic versus asymptomatic subjects, and (3) static versus dynamic kinematics. Quality of life (QOL) was also measured. GS implants only had a small but significant difference in patellofemoral translation in early flexion; no other differences were found for the kinematics or QOL. For all symptomatic subjects, differences in kinematics or surgical parameters were found, suggesting the cause for the subject’s postoperative pain. Static and dynamic kinematics were comparable in all but one case, where internal/external tibial rotation differed.","abstract_has_math":false,"creators":["Saevarsson, Stefan Karl"],"institution":"Graduate Studies","degree_name":"Master of Science (MSc)","degree_level":null,"degree_discipline":"Biomedical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Anglin, Carolyn"],"committee_chairs":[],"committee_members":[],"year":2012,"date_issued":"2012-06-26","date_published":"2012-06-26","updated_at":"2026-11-19T07:25:18Z","subjects":["Engineering--Biomedical"],"languages":["eng"],"rights":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/11023/100"],"render_values":[{"text":"http://hdl.handle.net/11023/100","href":"https://hdl.handle.net/11023/100","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.11575/PRISM/28467","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.11575/PRISM/28467","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://ucalgary.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aucalgary.scholaris.ca%3A11023%2F100","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Anglin, Carolyn"]},{"key":"dc:creator","label":"Author","values":["Saevarsson, Stefan Karl"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2012-06-26T22:12:21Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2012-11-13T08:01:10Z"]},{"key":"dc:date.issued","label":"Date","values":["2012-06-26"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["2012"]},{"key":"dc:publisher.faculty","label":"Dc Publisher Faculty","values":["Graduate Studies"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Calgary"]},{"key":"dc:publisher.place","label":"Dc Publisher Place","values":["Calgary"]},{"key":"dc:type","label":"Dc Type","values":["master thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MSc)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Calgary"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Engineering--Biomedical"]},{"key":"dc:subject.classification","label":"Dc Subject Classification","values":["Total Knee Replacemnts","Pain","Component Design","Imaging","Radiology","Quality of Life"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Saevarsson, S. K. (2012). Total Knee Replacements: Component Design, Pain Prevention and Research Techniques (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca. doi:10.11575/PRISM/28467"]},{"key":"dc:identifier.doi","label":"DOI","values":["http://dx.doi.org/10.11575/PRISM/28467"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/11023/100"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"atmire:migration.oldid","label":"Atmire Migration Oldid","values":["143"]},{"key":"dc:description.abstract","label":"Abstract","values":["Total knee arthroplasty is a surgical procedure in which the knee is resurfaced with implants to relieve pain. This thesis presents computed tomography and radiography methods to determine the relative position (kinematics) for the patellofemoral and tibiofemoral joints in vivo for a full range of motion, as well as parameters related to surgical technique. These methods were used to compare: (1) subjects with gender-specific (GS) versus traditional implant designs, (2) symptomatic versus asymptomatic subjects, and (3) static versus dynamic kinematics. Quality of life (QOL) was also measured. GS implants only had a small but significant difference in patellofemoral translation in early flexion; no other differences were found for the kinematics or QOL. For all symptomatic subjects, differences in kinematics or surgical parameters were found, suggesting the cause for the subject’s postoperative pain. Static and dynamic kinematics were comparable in all but one case, where internal/external tibial rotation differed."]},{"key":"dc:title","label":"Title","values":["Total Knee Replacements: Component Design, Pain Prevention and Research Techniques"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:request.copy","label":"Local Request Copy","values":["true"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"atmire:migration.oldid":["143"],"dc:contributor.advisor":["Anglin, Carolyn"],"dc:creator":["Saevarsson, Stefan Karl"],"dc:date.accessioned":["2012-06-26T22:12:21Z"],"dc:date.available":["2012-11-13T08:01:10Z"],"dc:date.issued":["2012-06-26"],"dc:date.submitted":["2012"],"dc:description.abstract":["Total knee arthroplasty is a surgical procedure in which the knee is resurfaced with implants to relieve pain. This thesis presents computed tomography and radiography methods to determine the relative position (kinematics) for the patellofemoral and tibiofemoral joints in vivo for a full range of motion, as well as parameters related to surgical technique. These methods were used to compare: (1) subjects with gender-specific (GS) versus traditional implant designs, (2) symptomatic versus asymptomatic subjects, and (3) static versus dynamic kinematics. Quality of life (QOL) was also measured. GS implants only had a small but significant difference in patellofemoral translation in early flexion; no other differences were found for the kinematics or QOL. For all symptomatic subjects, differences in kinematics or surgical parameters were found, suggesting the cause for the subject’s postoperative pain. Static and dynamic kinematics were comparable in all but one case, where internal/external tibial rotation differed."],"dc:identifier.citation":["Saevarsson, S. K. (2012). Total Knee Replacements: Component Design, Pain Prevention and Research Techniques (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca. doi:10.11575/PRISM/28467"],"dc:identifier.doi":["http://dx.doi.org/10.11575/PRISM/28467"],"dc:identifier.uri":["http://hdl.handle.net/11023/100"],"dc:language.iso":["eng"],"dc:publisher.faculty":["Graduate Studies"],"dc:publisher.institution":["University of Calgary"],"dc:publisher.place":["Calgary"],"dc:rights":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."],"dc:subject":["Engineering--Biomedical"],"dc:subject.classification":["Total Knee Replacemnts","Pain","Component Design","Imaging","Radiology","Quality of Life"],"dc:title":["Total Knee Replacements: Component Design, Pain Prevention and Research Techniques"],"dc:type":["master thesis"],"dspace:entity.type":["Publication"],"local:request.copy":["true"],"others:access_status":["open.access"],"thesis:degree_discipline":["Biomedical Engineering"],"thesis:degree_name":["Master of Science (MSc)"],"thesis:institution_name":["University of Calgary"]},"updated_at":"2026-11-19T07:25:18Z"}