{"id":{"repo_id":"calgary","oai_identifier":"oai:ucalgary.scholaris.ca:11023/1141"},"canonical_url":"https://search.ndltd.org/etd/calgary/oai:ucalgary.scholaris.ca:11023/1141","repository":{"repo_id":"calgary","name":"University of Calgary","base_url":"https://ucalgary.scholaris.ca/server/oai/request"},"display":{"title":"Development and Evaluation of a Decision Support System for Operation of Small Water Treatment Systems","abstract":"Operation of a water treatment plant (WTP) requires understanding of treatment technology and how operations are affected by source water quality. Small WTPs generally rely on less experienced operators who may not be able to adapt to the changing conditions, or quickly identify problems. A decision support system (DSS) was developed for small WTPs to assess the treatment of microbial pathogens with common treatment technologies. The DSS includes fault trees, performance functions, quantitative microbial risk assessment, and data management capabilities in an integrated spreadsheet (Excel based) tool that could be coupled with an existing SCADA system. The utility of the DSS was evaluated based on eight case-studies using data from small WTPs in Alberta. It was determined that the DSS was able to effectively identify poorly performing WTPs that inadequately treat source water. Implementation of the DSS into an operating WTP is required to determine whether this tool can be utilized by operators in real world applications.","abstract_html":"Operation of a water treatment plant (WTP) requires understanding of treatment technology and how operations are affected by source water quality. Small WTPs generally rely on less experienced operators who may not be able to adapt to the changing conditions, or quickly identify problems. A decision support system (DSS) was developed for small WTPs to assess the treatment of microbial pathogens with common treatment technologies. The DSS includes fault trees, performance functions, quantitative microbial risk assessment, and data management capabilities in an integrated spreadsheet (Excel based) tool that could be coupled with an existing SCADA system. The utility of the DSS was evaluated based on eight case-studies using data from small WTPs in Alberta. It was determined that the DSS was able to effectively identify poorly performing WTPs that inadequately treat source water. Implementation of the DSS into an operating WTP is required to determine whether this tool can be utilized by operators in real world applications.","abstract_has_math":false,"creators":["Stein, Daniel Ira"],"institution":"Graduate Studies","degree_name":"Master of Science (MSc)","degree_level":null,"degree_discipline":"Civil Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Achari, Gopal","Sadiq, Rehan"],"committee_chairs":[],"committee_members":[],"year":2013,"date_issued":"2013-10-09","date_published":"2013-10-09","updated_at":"2026-11-19T07:30:43Z","subjects":["Environmental Sciences","Engineering--Civil","Engineering--Environmental"],"languages":["eng"],"rights":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/11023/1141"],"render_values":[{"text":"http://hdl.handle.net/11023/1141","href":"https://hdl.handle.net/11023/1141","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.11575/PRISM/25640","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.11575/PRISM/25640","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Acalgary%3Aoai%3Aucalgary.scholaris.ca%3A11023%2F1141","prefix":"oai_dc"},"source_record":{"url":"https://ucalgary.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aucalgary.scholaris.ca%3A11023%2F1141","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Achari, Gopal","Sadiq, Rehan"]},{"key":"dc:creator","label":"Author","values":["Stein, Daniel Ira"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2013-10-09T19:51:22Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2014-03-15T07:00:14Z"]},{"key":"dc:date.issued","label":"Date","values":["2013-10-09"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["2013"]},{"key":"dc:publisher.faculty","label":"Dc Publisher Faculty","values":["Graduate Studies"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Calgary"]},{"key":"dc:publisher.place","label":"Dc Publisher Place","values":["Calgary"]},{"key":"dc:type","label":"Dc Type","values":["master thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Civil Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MSc)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Calgary"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Environmental Sciences","Engineering--Civil","Engineering--Environmental"]},{"key":"dc:subject.classification","label":"Dc Subject Classification","values":["Water","Pathogen","treatment"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Stein, D. I. (2013). Development and Evaluation of a Decision Support System for Operation of Small Water Treatment Systems (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca. doi:10.11575/PRISM/25640"]},{"key":"dc:identifier.doi","label":"DOI","values":["http://dx.doi.org/10.11575/PRISM/25640"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/11023/1141"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"atmire:migration.oldid","label":"Atmire Migration Oldid","values":["1601"]},{"key":"dc:description.abstract","label":"Abstract","values":["Operation of a water treatment plant (WTP) requires understanding of treatment technology and how operations are affected by source water quality. Small WTPs generally rely on less experienced operators who may not be able to adapt to the changing conditions, or quickly identify problems. A decision support system (DSS) was developed for small WTPs to assess the treatment of microbial pathogens with common treatment technologies. The DSS includes fault trees, performance functions, quantitative microbial risk assessment, and data management capabilities in an integrated spreadsheet (Excel based) tool that could be coupled with an existing SCADA system. The utility of the DSS was evaluated based on eight case-studies using data from small WTPs in Alberta. It was determined that the DSS was able to effectively identify poorly performing WTPs that inadequately treat source water. Implementation of the DSS into an operating WTP is required to determine whether this tool can be utilized by operators in real world applications."]},{"key":"dc:title","label":"Title","values":["Development and Evaluation of a Decision Support System for Operation of Small Water Treatment Systems"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:request.copy","label":"Local Request Copy","values":["true"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"atmire:migration.oldid":["1601"],"dc:contributor.advisor":["Achari, Gopal","Sadiq, Rehan"],"dc:creator":["Stein, Daniel Ira"],"dc:date.accessioned":["2013-10-09T19:51:22Z"],"dc:date.available":["2014-03-15T07:00:14Z"],"dc:date.issued":["2013-10-09"],"dc:date.submitted":["2013"],"dc:description.abstract":["Operation of a water treatment plant (WTP) requires understanding of treatment technology and how operations are affected by source water quality. Small WTPs generally rely on less experienced operators who may not be able to adapt to the changing conditions, or quickly identify problems. A decision support system (DSS) was developed for small WTPs to assess the treatment of microbial pathogens with common treatment technologies. The DSS includes fault trees, performance functions, quantitative microbial risk assessment, and data management capabilities in an integrated spreadsheet (Excel based) tool that could be coupled with an existing SCADA system. The utility of the DSS was evaluated based on eight case-studies using data from small WTPs in Alberta. It was determined that the DSS was able to effectively identify poorly performing WTPs that inadequately treat source water. Implementation of the DSS into an operating WTP is required to determine whether this tool can be utilized by operators in real world applications."],"dc:identifier.citation":["Stein, D. I. (2013). Development and Evaluation of a Decision Support System for Operation of Small Water Treatment Systems (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca. doi:10.11575/PRISM/25640"],"dc:identifier.doi":["http://dx.doi.org/10.11575/PRISM/25640"],"dc:identifier.uri":["http://hdl.handle.net/11023/1141"],"dc:language.iso":["eng"],"dc:publisher.faculty":["Graduate Studies"],"dc:publisher.institution":["University of Calgary"],"dc:publisher.place":["Calgary"],"dc:rights":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."],"dc:subject":["Environmental Sciences","Engineering--Civil","Engineering--Environmental"],"dc:subject.classification":["Water","Pathogen","treatment"],"dc:title":["Development and Evaluation of a Decision Support System for Operation of Small Water Treatment Systems"],"dc:type":["master thesis"],"dspace:entity.type":["Publication"],"local:request.copy":["true"],"others:access_status":["open.access"],"thesis:degree_discipline":["Civil Engineering"],"thesis:degree_name":["Master of Science (MSc)"],"thesis:institution_name":["University of Calgary"]},"updated_at":"2026-11-19T07:30:43Z"}