{"id":{"repo_id":"calgary","oai_identifier":"oai:ucalgary.scholaris.ca:11023/1295"},"canonical_url":"https://search.ndltd.org/etd/calgary/oai:ucalgary.scholaris.ca:11023/1295","repository":{"repo_id":"calgary","name":"University of Calgary","base_url":"https://ucalgary.scholaris.ca/server/oai/request"},"display":{"title":"On the Transition of Non-Newtonian Blood Analogs in Straight and Stenosed Pipe Flow","abstract":"The non-linear viscous assumption of blood is evaluated through the use of an aqueous xanthan gum blood analog compared to a commonly used Newtonian analog in in vitro models of healthy and stenotic arteries. Pressure drop of unobstructed steady, unsteady, and post-stenotic flows were measured across laminar, transitional and turbulent regimes of Newtonian pipe flow. Results have shown that the non-Newtonian blood analog could delay the onset of transition and extend laminar flow behaviour to a Reynolds number of 3200 which showed on a macroscale level a good agreement with porcine blood. Subsequently, similar delayed transition was observed for unsteady flow at Womersley numbers of 4 and 6. For post-stenotic flows, the Newtonian to non-Newtonian minor loss ratios were lower than the unobstructed arterial model ratios, suggesting an elongation of the recirculation region for the non-Newtonian analog. These findings indicate the importance of the non-Newtonian viscous behaviour of blood on the resultant flow behaviour and cardiovascular pathologies in such environments.","abstract_html":"The non-linear viscous assumption of blood is evaluated through the use of an aqueous xanthan gum blood analog compared to a commonly used Newtonian analog in in vitro models of healthy and stenotic arteries. Pressure drop of unobstructed steady, unsteady, and post-stenotic flows were measured across laminar, transitional and turbulent regimes of Newtonian pipe flow. Results have shown that the non-Newtonian blood analog could delay the onset of transition and extend laminar flow behaviour to a Reynolds number of 3200 which showed on a macroscale level a good agreement with porcine blood. Subsequently, similar delayed transition was observed for unsteady flow at Womersley numbers of 4 and 6. For post-stenotic flows, the Newtonian to non-Newtonian minor loss ratios were lower than the unobstructed arterial model ratios, suggesting an elongation of the recirculation region for the non-Newtonian analog. These findings indicate the importance of the non-Newtonian viscous behaviour of blood on the resultant flow behaviour and cardiovascular pathologies in such environments.","abstract_has_math":false,"creators":["Li, Lin"],"institution":"Graduate Studies","degree_name":"Master of Science (MSc)","degree_level":null,"degree_discipline":"Biomedical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Rival, David E."],"committee_chairs":[],"committee_members":[],"year":2014,"date_issued":"2014-01-27","date_published":"2014-01-27","updated_at":"2026-11-19T07:27:56Z","subjects":["Fluid and Plasma","Engineering--Biomedical","Engineering--Mechanical"],"languages":["eng"],"rights":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/11023/1295"],"render_values":[{"text":"http://hdl.handle.net/11023/1295","href":"https://hdl.handle.net/11023/1295","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.11575/PRISM/27198","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.11575/PRISM/27198","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Acalgary%3Aoai%3Aucalgary.scholaris.ca%3A11023%2F1295","prefix":"oai_dc"},"source_record":{"url":"https://ucalgary.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aucalgary.scholaris.ca%3A11023%2F1295","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Rival, David E."]},{"key":"dc:creator","label":"Author","values":["Li, Lin"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2014-01-27T21:00:49Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2014-03-15T07:00:19Z"]},{"key":"dc:date.issued","label":"Date","values":["2014-01-27"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["2014"]},{"key":"dc:publisher.faculty","label":"Dc Publisher Faculty","values":["Graduate Studies"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Calgary"]},{"key":"dc:publisher.place","label":"Dc Publisher Place","values":["Calgary"]},{"key":"dc:type","label":"Dc Type","values":["master thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MSc)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Calgary"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Fluid and Plasma","Engineering--Biomedical","Engineering--Mechanical"]},{"key":"dc:subject.classification","label":"Dc Subject Classification","values":["Non-Newtonian","Blood analog","Natural transition","Shear layer induced transition","Stenosis"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Li, L. (2014). On the Transition of Non-Newtonian Blood Analogs in Straight and Stenosed Pipe Flow (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca. doi:10.11575/PRISM/27198"]},{"key":"dc:identifier.doi","label":"DOI","values":["http://dx.doi.org/10.11575/PRISM/27198"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/11023/1295"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"atmire:migration.oldid","label":"Atmire Migration Oldid","values":["1818"]},{"key":"dc:description.abstract","label":"Abstract","values":["The non-linear viscous assumption of blood is evaluated through the use of an aqueous xanthan gum blood analog compared to a commonly used Newtonian analog in in vitro models of healthy and stenotic arteries. Pressure drop of unobstructed steady, unsteady, and post-stenotic flows were measured across laminar, transitional and turbulent regimes of Newtonian pipe flow. Results have shown that the non-Newtonian blood analog could delay the onset of transition and extend laminar flow behaviour to a Reynolds number of 3200 which showed on a macroscale level a good agreement with porcine blood. Subsequently, similar delayed transition was observed for unsteady flow at Womersley numbers of 4 and 6. For post-stenotic flows, the Newtonian to non-Newtonian minor loss ratios were lower than the unobstructed arterial model ratios, suggesting an elongation of the recirculation region for the non-Newtonian analog. These findings indicate the importance of the non-Newtonian viscous behaviour of blood on the resultant flow behaviour and cardiovascular pathologies in such environments."]},{"key":"dc:title","label":"Title","values":["On the Transition of Non-Newtonian Blood Analogs in Straight and Stenosed Pipe Flow"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:request.copy","label":"Local Request Copy","values":["true"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"atmire:migration.oldid":["1818"],"dc:contributor.advisor":["Rival, David E."],"dc:creator":["Li, Lin"],"dc:date.accessioned":["2014-01-27T21:00:49Z"],"dc:date.available":["2014-03-15T07:00:19Z"],"dc:date.issued":["2014-01-27"],"dc:date.submitted":["2014"],"dc:description.abstract":["The non-linear viscous assumption of blood is evaluated through the use of an aqueous xanthan gum blood analog compared to a commonly used Newtonian analog in in vitro models of healthy and stenotic arteries. Pressure drop of unobstructed steady, unsteady, and post-stenotic flows were measured across laminar, transitional and turbulent regimes of Newtonian pipe flow. Results have shown that the non-Newtonian blood analog could delay the onset of transition and extend laminar flow behaviour to a Reynolds number of 3200 which showed on a macroscale level a good agreement with porcine blood. Subsequently, similar delayed transition was observed for unsteady flow at Womersley numbers of 4 and 6. For post-stenotic flows, the Newtonian to non-Newtonian minor loss ratios were lower than the unobstructed arterial model ratios, suggesting an elongation of the recirculation region for the non-Newtonian analog. These findings indicate the importance of the non-Newtonian viscous behaviour of blood on the resultant flow behaviour and cardiovascular pathologies in such environments."],"dc:identifier.citation":["Li, L. (2014). On the Transition of Non-Newtonian Blood Analogs in Straight and Stenosed Pipe Flow (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca. doi:10.11575/PRISM/27198"],"dc:identifier.doi":["http://dx.doi.org/10.11575/PRISM/27198"],"dc:identifier.uri":["http://hdl.handle.net/11023/1295"],"dc:language.iso":["eng"],"dc:publisher.faculty":["Graduate Studies"],"dc:publisher.institution":["University of Calgary"],"dc:publisher.place":["Calgary"],"dc:rights":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."],"dc:subject":["Fluid and Plasma","Engineering--Biomedical","Engineering--Mechanical"],"dc:subject.classification":["Non-Newtonian","Blood analog","Natural transition","Shear layer induced transition","Stenosis"],"dc:title":["On the Transition of Non-Newtonian Blood Analogs in Straight and Stenosed Pipe Flow"],"dc:type":["master thesis"],"dspace:entity.type":["Publication"],"local:request.copy":["true"],"others:access_status":["open.access"],"thesis:degree_discipline":["Biomedical Engineering"],"thesis:degree_name":["Master of Science (MSc)"],"thesis:institution_name":["University of Calgary"]},"updated_at":"2026-11-19T07:27:56Z"}