{"id":{"repo_id":"calgary","oai_identifier":"oai:ucalgary.scholaris.ca:11023/1328"},"canonical_url":"https://search.ndltd.org/etd/calgary/oai:ucalgary.scholaris.ca:11023/1328","repository":{"repo_id":"calgary","name":"University of Calgary","base_url":"https://ucalgary.scholaris.ca/server/oai/request"},"display":{"title":"Effect of Disturbance Model Selection upon Performance, Robustness and Control Effort of Model Predictive Controllers","abstract":"Unmeasured disturbances are encountered in the chemical process industries but modelling them accurately can be a difficult task. Instead, commercial Model Predictive Control packages assume various disturbance models a priori. In an attempt to identify the best default model, this research evaluates closed-loop properties such as best achievable servo and regulatory performances, robustness and control effort associated with selected disturbance models. Results show that poles of assumed disturbance model should match those of the actual disturbance as closely as possible. Further, numerator polynomial of the model, or “T-filter”, represents a strong handle for affecting compromise between robustness and achievable regulatory performance. Rather than adopting a default T-filter (e.g. z = 0.8) it is recommended that selection of the order and pole of the T-filter be made on a case-by-case basis. Detailed guidelines for choosing these parameters are provided for processes whose open-loop dynamics can be well-approximated as first-order-plus-deadtime.","abstract_html":"Unmeasured disturbances are encountered in the chemical process industries but modelling them accurately can be a difficult task. Instead, commercial Model Predictive Control packages assume various disturbance models a priori. In an attempt to identify the best default model, this research evaluates closed-loop properties such as best achievable servo and regulatory performances, robustness and control effort associated with selected disturbance models. Results show that poles of assumed disturbance model should match those of the actual disturbance as closely as possible. Further, numerator polynomial of the model, or “T-filter”, represents a strong handle for affecting compromise between robustness and achievable regulatory performance. Rather than adopting a default T-filter (e.g. z = 0.8) it is recommended that selection of the order and pole of the T-filter be made on a case-by-case basis. Detailed guidelines for choosing these parameters are provided for processes whose open-loop dynamics can be well-approximated as first-order-plus-deadtime.","abstract_has_math":false,"creators":["Liu, Wenyu"],"institution":"Graduate Studies","degree_name":"Master of Engineering (MEng)","degree_level":null,"degree_discipline":"Chemical and Petroleum Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Foley, Michael"],"committee_chairs":[],"committee_members":[],"year":2014,"date_issued":"2014-01-29","date_published":"2014-01-29","updated_at":"2026-11-19T07:28:03Z","subjects":["Engineering--Chemical"],"languages":["eng"],"rights":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/11023/1328"],"render_values":[{"text":"http://hdl.handle.net/11023/1328","href":"https://hdl.handle.net/11023/1328","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.11575/PRISM/25796","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.11575/PRISM/25796","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Acalgary%3Aoai%3Aucalgary.scholaris.ca%3A11023%2F1328","prefix":"oai_dc"},"source_record":{"url":"https://ucalgary.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aucalgary.scholaris.ca%3A11023%2F1328","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Foley, Michael"]},{"key":"dc:creator","label":"Author","values":["Liu, Wenyu"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2014-01-29T21:50:31Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2014-03-15T07:00:20Z"]},{"key":"dc:date.issued","label":"Date","values":["2014-01-29"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["2014"]},{"key":"dc:publisher.faculty","label":"Dc Publisher Faculty","values":["Graduate Studies"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Calgary"]},{"key":"dc:publisher.place","label":"Dc Publisher Place","values":["Calgary"]},{"key":"dc:type","label":"Dc Type","values":["master thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Chemical and Petroleum Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Engineering (MEng)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Calgary"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Engineering--Chemical"]},{"key":"dc:subject.classification","label":"Dc Subject Classification","values":["disturbance","MPC","Control"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Liu, W. (2014). Effect of Disturbance Model Selection upon Performance, Robustness and Control Effort of Model Predictive Controllers (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca. doi:10.11575/PRISM/25796"]},{"key":"dc:identifier.doi","label":"DOI","values":["http://dx.doi.org/10.11575/PRISM/25796"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/11023/1328"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"atmire:migration.oldid","label":"Atmire Migration Oldid","values":["1841"]},{"key":"dc:description.abstract","label":"Abstract","values":["Unmeasured disturbances are encountered in the chemical process industries but modelling them accurately can be a difficult task. Instead, commercial Model Predictive Control packages assume various disturbance models a priori. In an attempt to identify the best default model, this research evaluates closed-loop properties such as best achievable servo and regulatory performances, robustness and control effort associated with selected disturbance models. Results show that poles of assumed disturbance model should match those of the actual disturbance as closely as possible. Further, numerator polynomial of the model, or “T-filter”, represents a strong handle for affecting compromise between robustness and achievable regulatory performance. Rather than adopting a default T-filter (e.g. z = 0.8) it is recommended that selection of the order and pole of the T-filter be made on a case-by-case basis. Detailed guidelines for choosing these parameters are provided for processes whose open-loop dynamics can be well-approximated as first-order-plus-deadtime."]},{"key":"dc:title","label":"Title","values":["Effect of Disturbance Model Selection upon Performance, Robustness and Control Effort of Model Predictive Controllers"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:request.copy","label":"Local Request Copy","values":["true"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"atmire:migration.oldid":["1841"],"dc:contributor.advisor":["Foley, Michael"],"dc:creator":["Liu, Wenyu"],"dc:date.accessioned":["2014-01-29T21:50:31Z"],"dc:date.available":["2014-03-15T07:00:20Z"],"dc:date.issued":["2014-01-29"],"dc:date.submitted":["2014"],"dc:description.abstract":["Unmeasured disturbances are encountered in the chemical process industries but modelling them accurately can be a difficult task. Instead, commercial Model Predictive Control packages assume various disturbance models a priori. In an attempt to identify the best default model, this research evaluates closed-loop properties such as best achievable servo and regulatory performances, robustness and control effort associated with selected disturbance models. Results show that poles of assumed disturbance model should match those of the actual disturbance as closely as possible. Further, numerator polynomial of the model, or “T-filter”, represents a strong handle for affecting compromise between robustness and achievable regulatory performance. Rather than adopting a default T-filter (e.g. z = 0.8) it is recommended that selection of the order and pole of the T-filter be made on a case-by-case basis. Detailed guidelines for choosing these parameters are provided for processes whose open-loop dynamics can be well-approximated as first-order-plus-deadtime."],"dc:identifier.citation":["Liu, W. (2014). Effect of Disturbance Model Selection upon Performance, Robustness and Control Effort of Model Predictive Controllers (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca. doi:10.11575/PRISM/25796"],"dc:identifier.doi":["http://dx.doi.org/10.11575/PRISM/25796"],"dc:identifier.uri":["http://hdl.handle.net/11023/1328"],"dc:language.iso":["eng"],"dc:publisher.faculty":["Graduate Studies"],"dc:publisher.institution":["University of Calgary"],"dc:publisher.place":["Calgary"],"dc:rights":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."],"dc:subject":["Engineering--Chemical"],"dc:subject.classification":["disturbance","MPC","Control"],"dc:title":["Effect of Disturbance Model Selection upon Performance, Robustness and Control Effort of Model Predictive Controllers"],"dc:type":["master thesis"],"dspace:entity.type":["Publication"],"local:request.copy":["true"],"others:access_status":["open.access"],"thesis:degree_discipline":["Chemical and Petroleum Engineering"],"thesis:degree_name":["Master of Engineering (MEng)"],"thesis:institution_name":["University of Calgary"]},"updated_at":"2026-11-19T07:28:03Z"}