{"id":{"repo_id":"calgary","oai_identifier":"oai:ucalgary.scholaris.ca:11023/1516"},"canonical_url":"https://search.ndltd.org/etd/calgary/oai:ucalgary.scholaris.ca:11023/1516","repository":{"repo_id":"calgary","name":"University of Calgary","base_url":"https://ucalgary.scholaris.ca/server/oai/request"},"display":{"title":"Cortical Porosity in Bone","abstract":"Osteoporosis (porous bones) is a disease that is characterized by decreased bone strength and increased risk of fracture due to loss of bone strength from decreased bone mass and deterioration of bone micro-architecture. In particular, cortical porosity (CtPo) significantly impacts bone strength and has been associated with the progression of the disease and the occurrence of fracture. Very recently, it has become possible to assess CtPo in the appendicular skeleton in vivo through the use of high-resolution peripheral quantitative computed tomography (HR-pQCT). There are two approaches to assessing CtPo from HR-pQCT imaging data based on a threshold-based or a density-based approach. The performance of both methods was compared against gold-standard synchrotron radiation micro computed tomography (SRu CT) measurements. The threshold-based approach was found to be more highly correlated with true values of CtPo than a density-based approach. Improved CtPo measures may lead to better imaging diagnostics to detect and monitor osteoporosis.","abstract_html":"Osteoporosis (porous bones) is a disease that is characterized by decreased bone strength and increased risk of fracture due to loss of bone strength from decreased bone mass and deterioration of bone micro-architecture. In particular, cortical porosity (CtPo) significantly impacts bone strength and has been associated with the progression of the disease and the occurrence of fracture. Very recently, it has become possible to assess CtPo in the appendicular skeleton in vivo through the use of high-resolution peripheral quantitative computed tomography (HR-pQCT). There are two approaches to assessing CtPo from HR-pQCT imaging data based on a threshold-based or a density-based approach. The performance of both methods was compared against gold-standard synchrotron radiation micro computed tomography (SRu CT) measurements. The threshold-based approach was found to be more highly correlated with true values of CtPo than a density-based approach. Improved CtPo measures may lead to better imaging diagnostics to detect and monitor osteoporosis.","abstract_has_math":false,"creators":["Jorgenson, Britta"],"institution":"Graduate Studies","degree_name":"Master of Science (MSc)","degree_level":null,"degree_discipline":"Biomedical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Boyd, Steven"],"committee_chairs":[],"committee_members":[],"year":2014,"date_issued":"2014-05-14","date_published":"2014-05-14","updated_at":"2026-11-19T07:37:35Z","subjects":["Education--Sciences"],"languages":["eng"],"rights":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/11023/1516"],"render_values":[{"text":"http://hdl.handle.net/11023/1516","href":"https://hdl.handle.net/11023/1516","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.11575/PRISM/25471","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.11575/PRISM/25471","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Acalgary%3Aoai%3Aucalgary.scholaris.ca%3A11023%2F1516","prefix":"oai_dc"},"source_record":{"url":"https://ucalgary.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aucalgary.scholaris.ca%3A11023%2F1516","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Boyd, Steven"]},{"key":"dc:creator","label":"Author","values":["Jorgenson, Britta"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2014-05-14T15:42:20Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2014-06-16T07:00:42Z"]},{"key":"dc:date.issued","label":"Date","values":["2014-05-14"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["2014"]},{"key":"dc:publisher.faculty","label":"Dc Publisher Faculty","values":["Graduate Studies"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Calgary"]},{"key":"dc:publisher.place","label":"Dc Publisher Place","values":["Calgary"]},{"key":"dc:type","label":"Dc Type","values":["master thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MSc)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Calgary"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Education--Sciences"]},{"key":"dc:subject.classification","label":"Dc Subject Classification","values":["Cortical Porosity"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Jorgenson, B. (2014). Cortical Porosity in Bone (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca. doi:10.11575/PRISM/25471"]},{"key":"dc:identifier.doi","label":"DOI","values":["http://dx.doi.org/10.11575/PRISM/25471"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/11023/1516"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"atmire:migration.oldid","label":"Atmire Migration Oldid","values":["2136"]},{"key":"dc:description.abstract","label":"Abstract","values":["Osteoporosis (porous bones) is a disease that is characterized by decreased bone strength and increased risk of fracture due to loss of bone strength from decreased bone mass and deterioration of bone micro-architecture. In particular, cortical porosity (CtPo) significantly impacts bone strength and has been associated with the progression of the disease and the occurrence of fracture. Very recently, it has become possible to assess CtPo in the appendicular skeleton in vivo through the use of high-resolution peripheral quantitative computed tomography (HR-pQCT). There are two approaches to assessing CtPo from HR-pQCT imaging data based on a threshold-based or a density-based approach. The performance of both methods was compared against gold-standard synchrotron radiation micro computed tomography (SRu CT) measurements. The threshold-based approach was found to be more highly correlated with true values of CtPo than a density-based approach. Improved CtPo measures may lead to better imaging diagnostics to detect and monitor osteoporosis."]},{"key":"dc:title","label":"Title","values":["Cortical Porosity in Bone"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:request.copy","label":"Local Request Copy","values":["true"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"atmire:migration.oldid":["2136"],"dc:contributor.advisor":["Boyd, Steven"],"dc:creator":["Jorgenson, Britta"],"dc:date.accessioned":["2014-05-14T15:42:20Z"],"dc:date.available":["2014-06-16T07:00:42Z"],"dc:date.issued":["2014-05-14"],"dc:date.submitted":["2014"],"dc:description.abstract":["Osteoporosis (porous bones) is a disease that is characterized by decreased bone strength and increased risk of fracture due to loss of bone strength from decreased bone mass and deterioration of bone micro-architecture. In particular, cortical porosity (CtPo) significantly impacts bone strength and has been associated with the progression of the disease and the occurrence of fracture. Very recently, it has become possible to assess CtPo in the appendicular skeleton in vivo through the use of high-resolution peripheral quantitative computed tomography (HR-pQCT). There are two approaches to assessing CtPo from HR-pQCT imaging data based on a threshold-based or a density-based approach. The performance of both methods was compared against gold-standard synchrotron radiation micro computed tomography (SRu CT) measurements. The threshold-based approach was found to be more highly correlated with true values of CtPo than a density-based approach. Improved CtPo measures may lead to better imaging diagnostics to detect and monitor osteoporosis."],"dc:identifier.citation":["Jorgenson, B. (2014). Cortical Porosity in Bone (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca. doi:10.11575/PRISM/25471"],"dc:identifier.doi":["http://dx.doi.org/10.11575/PRISM/25471"],"dc:identifier.uri":["http://hdl.handle.net/11023/1516"],"dc:language.iso":["eng"],"dc:publisher.faculty":["Graduate Studies"],"dc:publisher.institution":["University of Calgary"],"dc:publisher.place":["Calgary"],"dc:rights":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."],"dc:subject":["Education--Sciences"],"dc:subject.classification":["Cortical Porosity"],"dc:title":["Cortical Porosity in Bone"],"dc:type":["master thesis"],"dspace:entity.type":["Publication"],"local:request.copy":["true"],"others:access_status":["open.access"],"thesis:degree_discipline":["Biomedical Engineering"],"thesis:degree_name":["Master of Science (MSc)"],"thesis:institution_name":["University of Calgary"]},"updated_at":"2026-11-19T07:37:35Z"}