{"id":{"repo_id":"calgary","oai_identifier":"oai:ucalgary.scholaris.ca:11023/1534"},"canonical_url":"https://search.ndltd.org/etd/calgary/oai:ucalgary.scholaris.ca:11023/1534","repository":{"repo_id":"calgary","name":"University of Calgary","base_url":"https://ucalgary.scholaris.ca/server/oai/request"},"display":{"title":"Experimental Validation of a Model for Predicting Ethanol/Water Vapor Permeation in Industrial Membrane Separation","abstract":"Renewable energy is one of the crucial elements for sustainable development. Ethanol makes up about 94% of the biofuels produced in the U.S. The rapidly growing market and the pursuit of net positive energy ethanol production systems puts pressure on the development of optimal production processes. Dehydrating ethanol to fuel grade specifications is a highly energy intensive step. Membrane technology, particularly vapor permeation is designed to improve energy and water efficiency in the dehydration of fuel-grade ethanol. Pilot-scale testing facilities were designed and built to test Whitefox Technologies industrial scale membrane cartridges. Along with operational data collected from larger Whitefox plants, a numerical model was experimentally validated. When incorporating leakage, a phenomena that occurs when feed and retentate by-pass the hollow fibers, the retentate stream concentration and flow were predicted within 1% and ±3% error, respectively. The permeate concentration was predicted to within ±7.6% and the flow rate ±8.1%.","abstract_html":"Renewable energy is one of the crucial elements for sustainable development. Ethanol makes up about 94% of the biofuels produced in the U.S. The rapidly growing market and the pursuit of net positive energy ethanol production systems puts pressure on the development of optimal production processes. Dehydrating ethanol to fuel grade specifications is a highly energy intensive step. Membrane technology, particularly vapor permeation is designed to improve energy and water efficiency in the dehydration of fuel-grade ethanol. Pilot-scale testing facilities were designed and built to test Whitefox Technologies industrial scale membrane cartridges. Along with operational data collected from larger Whitefox plants, a numerical model was experimentally validated. When incorporating leakage, a phenomena that occurs when feed and retentate by-pass the hollow fibers, the retentate stream concentration and flow were predicted within 1% and ±3% error, respectively. The permeate concentration was predicted to within ±7.6% and the flow rate ±8.1%.","abstract_has_math":false,"creators":["Lopez, Jessica"],"institution":"Graduate Studies","degree_name":"Master of Science (MSc)","degree_level":null,"degree_discipline":"Chemical and Petroleum Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Foley, Michael"],"committee_chairs":[],"committee_members":[],"year":2014,"date_issued":"2014-05-21","date_published":"2014-05-21","updated_at":"2026-11-19T07:27:44Z","subjects":["Engineering","Engineering--Chemical"],"languages":["eng"],"rights":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/11023/1534"],"render_values":[{"text":"http://hdl.handle.net/11023/1534","href":"https://hdl.handle.net/11023/1534","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.11575/PRISM/26070","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.11575/PRISM/26070","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Acalgary%3Aoai%3Aucalgary.scholaris.ca%3A11023%2F1534","prefix":"oai_dc"},"source_record":{"url":"https://ucalgary.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aucalgary.scholaris.ca%3A11023%2F1534","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Foley, Michael"]},{"key":"dc:creator","label":"Author","values":["Lopez, Jessica"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2014-05-21T15:30:03Z"]},{"key":"dc:date.issued","label":"Date","values":["2014-05-21"]},{"key":"dc:date.liftdate","label":"Dc Date Liftdate","values":["2019-05-20T15:30:03Z"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["2014"]},{"key":"dc:publisher.faculty","label":"Dc Publisher Faculty","values":["Graduate Studies"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Calgary"]},{"key":"dc:publisher.place","label":"Dc Publisher Place","values":["Calgary"]},{"key":"dc:type","label":"Dc Type","values":["master thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Chemical and Petroleum Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MSc)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Calgary"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Engineering","Engineering--Chemical"]},{"key":"dc:subject.classification","label":"Dc Subject Classification","values":["Ethanol","Membrane"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Lopez, J. (2014). Experimental Validation of a Model for Predicting Ethanol/Water Vapor Permeation in Industrial Membrane Separation (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca. doi:10.11575/PRISM/26070"]},{"key":"dc:identifier.doi","label":"DOI","values":["http://dx.doi.org/10.11575/PRISM/26070"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/11023/1534"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"atmire:migration.oldid","label":"Atmire Migration Oldid","values":["2184"]},{"key":"dc:description.abstract","label":"Abstract","values":["Renewable energy is one of the crucial elements for sustainable development. Ethanol makes up about 94% of the biofuels produced in the U.S. The rapidly growing market and the pursuit of net positive energy ethanol production systems puts pressure on the development of optimal production processes. Dehydrating ethanol to fuel grade specifications is a highly energy intensive step. Membrane technology, particularly vapor permeation is designed to improve energy and water efficiency in the dehydration of fuel-grade ethanol. Pilot-scale testing facilities were designed and built to test Whitefox Technologies industrial scale membrane cartridges. Along with operational data collected from larger Whitefox plants, a numerical model was experimentally validated. When incorporating leakage, a phenomena that occurs when feed and retentate by-pass the hollow fibers, the retentate stream concentration and flow were predicted within 1% and ±3% error, respectively. The permeate concentration was predicted to within ±7.6% and the flow rate ±8.1%."]},{"key":"dc:embargo.terms","label":"Dc Embargo Terms","values":["5 years"]},{"key":"dc:title","label":"Title","values":["Experimental Validation of a Model for Predicting Ethanol/Water Vapor Permeation in Industrial Membrane Separation"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:request.copy","label":"Local Request Copy","values":["true"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"atmire:migration.oldid":["2184"],"dc:contributor.advisor":["Foley, Michael"],"dc:creator":["Lopez, Jessica"],"dc:date.accessioned":["2014-05-21T15:30:03Z"],"dc:date.issued":["2014-05-21"],"dc:date.liftdate":["2019-05-20T15:30:03Z"],"dc:date.submitted":["2014"],"dc:description.abstract":["Renewable energy is one of the crucial elements for sustainable development. Ethanol makes up about 94% of the biofuels produced in the U.S. The rapidly growing market and the pursuit of net positive energy ethanol production systems puts pressure on the development of optimal production processes. Dehydrating ethanol to fuel grade specifications is a highly energy intensive step. Membrane technology, particularly vapor permeation is designed to improve energy and water efficiency in the dehydration of fuel-grade ethanol. Pilot-scale testing facilities were designed and built to test Whitefox Technologies industrial scale membrane cartridges. Along with operational data collected from larger Whitefox plants, a numerical model was experimentally validated. When incorporating leakage, a phenomena that occurs when feed and retentate by-pass the hollow fibers, the retentate stream concentration and flow were predicted within 1% and ±3% error, respectively. The permeate concentration was predicted to within ±7.6% and the flow rate ±8.1%."],"dc:embargo.terms":["5 years"],"dc:identifier.citation":["Lopez, J. (2014). Experimental Validation of a Model for Predicting Ethanol/Water Vapor Permeation in Industrial Membrane Separation (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca. doi:10.11575/PRISM/26070"],"dc:identifier.doi":["http://dx.doi.org/10.11575/PRISM/26070"],"dc:identifier.uri":["http://hdl.handle.net/11023/1534"],"dc:language.iso":["eng"],"dc:publisher.faculty":["Graduate Studies"],"dc:publisher.institution":["University of Calgary"],"dc:publisher.place":["Calgary"],"dc:rights":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."],"dc:subject":["Engineering","Engineering--Chemical"],"dc:subject.classification":["Ethanol","Membrane"],"dc:title":["Experimental Validation of a Model for Predicting Ethanol/Water Vapor Permeation in Industrial Membrane Separation"],"dc:type":["master thesis"],"dspace:entity.type":["Publication"],"local:request.copy":["true"],"others:access_status":["open.access"],"thesis:degree_discipline":["Chemical and Petroleum Engineering"],"thesis:degree_name":["Master of Science (MSc)"],"thesis:institution_name":["University of Calgary"]},"updated_at":"2026-11-19T07:27:44Z"}