{"id":{"repo_id":"calgary","oai_identifier":"oai:ucalgary.scholaris.ca:11023/163"},"canonical_url":"https://search.ndltd.org/etd/calgary/oai:ucalgary.scholaris.ca:11023/163","repository":{"repo_id":"calgary","name":"University of Calgary","base_url":"https://ucalgary.scholaris.ca/server/oai/request"},"display":{"title":"Pneumatic compression devices during hemodialysis","abstract":"Hemodynamic stability during hemodialysis requires maintenance of central blood volume (CBV), which pneumatic compression devices (PCDs) may help preserve. We performed a randomized crossover trial to determine the effect of PCDs on CBV during hemodialysis. Fifty-one patients were randomized to begin the first of two hemodialysis sessions with or without PCDs. The median change in CBV for PCDs vs control was -0.08 vs -0.05L (p=0.62). There was no difference in change in cardiac output (-0.63 vs -0.49L/min, p=0.78) or systemic vascular resistance (+1.30 vs +1.55mmHg/L/min, p=0.67) for PCDs vs control. There was a greater reduction in total body water (-2.6 vs -2.3L, p=0.05) and intracellular fluid volume (-1.3 vs -1.1L, p=0.03), with no difference in extracellular fluid volume (-1.3 vs -1.2L, p=0.09) for PCDs vs control. Compared with standard of care, PCDs have no effect on intradialytic hemodynamic parameters, including CBV, although they may allow greater capacity for fluid removal.","abstract_html":"Hemodynamic stability during hemodialysis requires maintenance of central blood volume (CBV), which pneumatic compression devices (PCDs) may help preserve. We performed a randomized crossover trial to determine the effect of PCDs on CBV during hemodialysis. Fifty-one patients were randomized to begin the first of two hemodialysis sessions with or without PCDs. The median change in CBV for PCDs vs control was -0.08 vs -0.05L (p=0.62). There was no difference in change in cardiac output (-0.63 vs -0.49L/min, p=0.78) or systemic vascular resistance (+1.30 vs +1.55mmHg/L/min, p=0.67) for PCDs vs control. There was a greater reduction in total body water (-2.6 vs -2.3L, p=0.05) and intracellular fluid volume (-1.3 vs -1.1L, p=0.03), with no difference in extracellular fluid volume (-1.3 vs -1.2L, p=0.09) for PCDs vs control. Compared with standard of care, PCDs have no effect on intradialytic hemodynamic parameters, including CBV, although they may allow greater capacity for fluid removal.","abstract_has_math":false,"creators":["Tai, Davina Julia"],"institution":"Graduate Studies","degree_name":"Master of Science (MSc)","degree_level":null,"degree_discipline":"Medical Science","degree_department":null,"school":null,"contributors":[],"advisors":["Ahmed, Sofia B.","MacRae, Jennifer M."],"committee_chairs":[],"committee_members":[],"year":2012,"date_issued":"2012-08-28","date_published":"2012-08-28","updated_at":"2026-11-19T07:27:18Z","subjects":["Medicine and Surgery"],"languages":["eng"],"rights":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/11023/163"],"render_values":[{"text":"http://hdl.handle.net/11023/163","href":"https://hdl.handle.net/11023/163","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.11575/PRISM/27373","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.11575/PRISM/27373","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Acalgary%3Aoai%3Aucalgary.scholaris.ca%3A11023%2F163","prefix":"oai_dc"},"source_record":{"url":"https://ucalgary.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aucalgary.scholaris.ca%3A11023%2F163","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Ahmed, Sofia B.","MacRae, Jennifer M."]},{"key":"dc:creator","label":"Author","values":["Tai, Davina Julia"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2012-08-28T14:53:06Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2012-11-13T08:01:22Z"]},{"key":"dc:date.issued","label":"Date","values":["2012-08-28"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["2012"]},{"key":"dc:publisher.faculty","label":"Dc Publisher Faculty","values":["Graduate Studies"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Calgary"]},{"key":"dc:publisher.place","label":"Dc Publisher Place","values":["Calgary"]},{"key":"dc:type","label":"Dc Type","values":["master thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Medical Science"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MSc)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Calgary"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Medicine and Surgery"]},{"key":"dc:subject.classification","label":"Dc Subject Classification","values":["Hemodialysis","Dialysis","Central Blood Volume","ESRD","Intradialytic Hypotension","Pneumatic Compression Devices","Hemodynamics"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Tai, D. J. (2012). Pneumatic compression devices during hemodialysis (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca. doi:10.11575/PRISM/27373"]},{"key":"dc:identifier.doi","label":"DOI","values":["http://dx.doi.org/10.11575/PRISM/27373"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/11023/163"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"atmire:migration.oldid","label":"Atmire Migration Oldid","values":["232"]},{"key":"dc:description.abstract","label":"Abstract","values":["Hemodynamic stability during hemodialysis requires maintenance of central blood volume (CBV), which pneumatic compression devices (PCDs) may help preserve. We performed a randomized crossover trial to determine the effect of PCDs on CBV during hemodialysis. Fifty-one patients were randomized to begin the first of two hemodialysis sessions with or without PCDs. The median change in CBV for PCDs vs control was -0.08 vs -0.05L (p=0.62). There was no difference in change in cardiac output (-0.63 vs -0.49L/min, p=0.78) or systemic vascular resistance (+1.30 vs +1.55mmHg/L/min, p=0.67) for PCDs vs control. There was a greater reduction in total body water (-2.6 vs -2.3L, p=0.05) and intracellular fluid volume (-1.3 vs -1.1L, p=0.03), with no difference in extracellular fluid volume (-1.3 vs -1.2L, p=0.09) for PCDs vs control. Compared with standard of care, PCDs have no effect on intradialytic hemodynamic parameters, including CBV, although they may allow greater capacity for fluid removal."]},{"key":"dc:title","label":"Title","values":["Pneumatic compression devices during hemodialysis"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:request.copy","label":"Local Request Copy","values":["true"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"atmire:migration.oldid":["232"],"dc:contributor.advisor":["Ahmed, Sofia B.","MacRae, Jennifer M."],"dc:creator":["Tai, Davina Julia"],"dc:date.accessioned":["2012-08-28T14:53:06Z"],"dc:date.available":["2012-11-13T08:01:22Z"],"dc:date.issued":["2012-08-28"],"dc:date.submitted":["2012"],"dc:description.abstract":["Hemodynamic stability during hemodialysis requires maintenance of central blood volume (CBV), which pneumatic compression devices (PCDs) may help preserve. We performed a randomized crossover trial to determine the effect of PCDs on CBV during hemodialysis. Fifty-one patients were randomized to begin the first of two hemodialysis sessions with or without PCDs. The median change in CBV for PCDs vs control was -0.08 vs -0.05L (p=0.62). There was no difference in change in cardiac output (-0.63 vs -0.49L/min, p=0.78) or systemic vascular resistance (+1.30 vs +1.55mmHg/L/min, p=0.67) for PCDs vs control. There was a greater reduction in total body water (-2.6 vs -2.3L, p=0.05) and intracellular fluid volume (-1.3 vs -1.1L, p=0.03), with no difference in extracellular fluid volume (-1.3 vs -1.2L, p=0.09) for PCDs vs control. Compared with standard of care, PCDs have no effect on intradialytic hemodynamic parameters, including CBV, although they may allow greater capacity for fluid removal."],"dc:identifier.citation":["Tai, D. J. (2012). Pneumatic compression devices during hemodialysis (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca. doi:10.11575/PRISM/27373"],"dc:identifier.doi":["http://dx.doi.org/10.11575/PRISM/27373"],"dc:identifier.uri":["http://hdl.handle.net/11023/163"],"dc:language.iso":["eng"],"dc:publisher.faculty":["Graduate Studies"],"dc:publisher.institution":["University of Calgary"],"dc:publisher.place":["Calgary"],"dc:rights":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."],"dc:subject":["Medicine and Surgery"],"dc:subject.classification":["Hemodialysis","Dialysis","Central Blood Volume","ESRD","Intradialytic Hypotension","Pneumatic Compression Devices","Hemodynamics"],"dc:title":["Pneumatic compression devices during hemodialysis"],"dc:type":["master thesis"],"dspace:entity.type":["Publication"],"local:request.copy":["true"],"others:access_status":["open.access"],"thesis:degree_discipline":["Medical Science"],"thesis:degree_name":["Master of Science (MSc)"],"thesis:institution_name":["University of Calgary"]},"updated_at":"2026-11-19T07:27:18Z"}