{"id":{"repo_id":"calgary","oai_identifier":"oai:ucalgary.scholaris.ca:11023/164"},"canonical_url":"https://search.ndltd.org/etd/calgary/oai:ucalgary.scholaris.ca:11023/164","repository":{"repo_id":"calgary","name":"University of Calgary","base_url":"https://ucalgary.scholaris.ca/server/oai/request"},"display":{"title":"Flammability limits of hydrogen-diluent mixtures in air","abstract":"The flammability limits of hydrogen-diluent fuel mixtures in air for upward and downward flame propagation at ambient pressure were determined experimentally. A wide range of diluent concentrations were examined, up to 95% by volume in the fuel mixture. The diluents employed were helium, argon, carbon dioxide and nitrogen. The effects of changes of the initial mixture temperature on the flammability limits were determined for fuel mixtures containing 50% diluent by volume. It was observed that helium was more effective than argon at narrowing the flammable range of hydrogen mixtures. The value of the lean flammability limit was increased to a greater extent by the addition of helium than carbon dioxide despite the low heat capacity of helium. Values of the flammability limits predicted using the constant adiabatic flame temperature concept are in generally good agreement with the experimentally obtained values. The agreement between the two sets of values was better for the rich flammability limits than the corresponding lean flammability limits and was particularly poor for lean mixtures involving high concentrations of helium.","abstract_html":"The flammability limits of hydrogen-diluent fuel mixtures in air for upward and downward flame propagation at ambient pressure were determined experimentally. A wide range of diluent concentrations were examined, up to 95% by volume in the fuel mixture. The diluents employed were helium, argon, carbon dioxide and nitrogen. The effects of changes of the initial mixture temperature on the flammability limits were determined for fuel mixtures containing 50% diluent by volume. It was observed that helium was more effective than argon at narrowing the flammable range of hydrogen mixtures. The value of the lean flammability limit was increased to a greater extent by the addition of helium than carbon dioxide despite the low heat capacity of helium. Values of the flammability limits predicted using the constant adiabatic flame temperature concept are in generally good agreement with the experimentally obtained values. The agreement between the two sets of values was better for the rich flammability limits than the corresponding lean flammability limits and was particularly poor for lean mixtures involving high concentrations of helium.","abstract_has_math":false,"creators":["Terpstra, Mark"],"institution":"Graduate Studies","degree_name":"Master of Science (MSc)","degree_level":null,"degree_discipline":"Mechanical and Manufacturing Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Wierzba, Ida","Karim, Ghazi"],"committee_chairs":[],"committee_members":[],"year":2012,"date_issued":"2012-08-28","date_published":"2012-08-28","updated_at":"2026-11-19T07:37:22Z","subjects":["Engineering--Mechanical"],"languages":["eng"],"rights":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/11023/164"],"render_values":[{"text":"http://hdl.handle.net/11023/164","href":"https://hdl.handle.net/11023/164","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.11575/PRISM/26185","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.11575/PRISM/26185","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Acalgary%3Aoai%3Aucalgary.scholaris.ca%3A11023%2F164","prefix":"oai_dc"},"source_record":{"url":"https://ucalgary.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aucalgary.scholaris.ca%3A11023%2F164","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Wierzba, Ida","Karim, Ghazi"]},{"key":"dc:creator","label":"Author","values":["Terpstra, Mark"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2012-08-28T14:54:18Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2012-11-13T08:01:23Z"]},{"key":"dc:date.issued","label":"Date","values":["2012-08-28"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["2012"]},{"key":"dc:publisher.faculty","label":"Dc Publisher Faculty","values":["Graduate Studies"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Calgary"]},{"key":"dc:publisher.place","label":"Dc Publisher Place","values":["Calgary"]},{"key":"dc:type","label":"Dc Type","values":["master thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical and Manufacturing Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MSc)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Calgary"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Engineering--Mechanical"]},{"key":"dc:subject.classification","label":"Dc Subject Classification","values":["Flammability","Hydrogen"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Terpstra, M. (2012). Flammability limits of hydrogen-diluent mixtures in air (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca. doi:10.11575/PRISM/26185"]},{"key":"dc:identifier.doi","label":"DOI","values":["http://dx.doi.org/10.11575/PRISM/26185"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/11023/164"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"atmire:migration.oldid","label":"Atmire Migration Oldid","values":["235"]},{"key":"dc:description.abstract","label":"Abstract","values":["The flammability limits of hydrogen-diluent fuel mixtures in air for upward and downward flame propagation at ambient pressure were determined experimentally. A wide range of diluent concentrations were examined, up to 95% by volume in the fuel mixture. The diluents employed were helium, argon, carbon dioxide and nitrogen. The effects of changes of the initial mixture temperature on the flammability limits were determined for fuel mixtures containing 50% diluent by volume. It was observed that helium was more effective than argon at narrowing the flammable range of hydrogen mixtures. The value of the lean flammability limit was increased to a greater extent by the addition of helium than carbon dioxide despite the low heat capacity of helium. Values of the flammability limits predicted using the constant adiabatic flame temperature concept are in generally good agreement with the experimentally obtained values. The agreement between the two sets of values was better for the rich flammability limits than the corresponding lean flammability limits and was particularly poor for lean mixtures involving high concentrations of helium."]},{"key":"dc:title","label":"Title","values":["Flammability limits of hydrogen-diluent mixtures in air"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:request.copy","label":"Local Request Copy","values":["true"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"atmire:migration.oldid":["235"],"dc:contributor.advisor":["Wierzba, Ida","Karim, Ghazi"],"dc:creator":["Terpstra, Mark"],"dc:date.accessioned":["2012-08-28T14:54:18Z"],"dc:date.available":["2012-11-13T08:01:23Z"],"dc:date.issued":["2012-08-28"],"dc:date.submitted":["2012"],"dc:description.abstract":["The flammability limits of hydrogen-diluent fuel mixtures in air for upward and downward flame propagation at ambient pressure were determined experimentally. A wide range of diluent concentrations were examined, up to 95% by volume in the fuel mixture. The diluents employed were helium, argon, carbon dioxide and nitrogen. The effects of changes of the initial mixture temperature on the flammability limits were determined for fuel mixtures containing 50% diluent by volume. It was observed that helium was more effective than argon at narrowing the flammable range of hydrogen mixtures. The value of the lean flammability limit was increased to a greater extent by the addition of helium than carbon dioxide despite the low heat capacity of helium. Values of the flammability limits predicted using the constant adiabatic flame temperature concept are in generally good agreement with the experimentally obtained values. The agreement between the two sets of values was better for the rich flammability limits than the corresponding lean flammability limits and was particularly poor for lean mixtures involving high concentrations of helium."],"dc:identifier.citation":["Terpstra, M. (2012). Flammability limits of hydrogen-diluent mixtures in air (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca. doi:10.11575/PRISM/26185"],"dc:identifier.doi":["http://dx.doi.org/10.11575/PRISM/26185"],"dc:identifier.uri":["http://hdl.handle.net/11023/164"],"dc:language.iso":["eng"],"dc:publisher.faculty":["Graduate Studies"],"dc:publisher.institution":["University of Calgary"],"dc:publisher.place":["Calgary"],"dc:rights":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."],"dc:subject":["Engineering--Mechanical"],"dc:subject.classification":["Flammability","Hydrogen"],"dc:title":["Flammability limits of hydrogen-diluent mixtures in air"],"dc:type":["master thesis"],"dspace:entity.type":["Publication"],"local:request.copy":["true"],"others:access_status":["open.access"],"thesis:degree_discipline":["Mechanical and Manufacturing Engineering"],"thesis:degree_name":["Master of Science (MSc)"],"thesis:institution_name":["University of Calgary"]},"updated_at":"2026-11-19T07:37:22Z"}