{"id":{"repo_id":"calgary","oai_identifier":"oai:ucalgary.scholaris.ca:11023/1799"},"canonical_url":"https://search.ndltd.org/etd/calgary/oai:ucalgary.scholaris.ca:11023/1799","repository":{"repo_id":"calgary","name":"University of Calgary","base_url":"https://ucalgary.scholaris.ca/server/oai/request"},"display":{"title":"Design and Testing of a Fingertip Haptic Interface","abstract":"Fingertip force sensitivity threshold, human resolution, multimodal feedback, and interface miniaturization for ultra-mobile devices such as smart watches and glasses are investigated in this thesis. An FHI (Fingertip Haptic Interface) was designed and built to measure the position and force resolution of the human fingertip. The thumb and forefinger resolutions were identified as 212um and 133um, respectively. The force threshold at which the forefinger detects pulses was found experimentally to be F(t) = .148t + 28.7 where t is the pulse width in ms, and F(t) is the fingertip force in mN. It was found that visual feedback dominates user input tasks, but during eyes-free usage haptic feedback provides an improvement that quickly dissipates with increased task difficulty. Finally, the smallest target size that can be reliably selected was found to be two to three times the smallest resolution of the index finger or thumb.","abstract_html":"Fingertip force sensitivity threshold, human resolution, multimodal feedback, and interface miniaturization for ultra-mobile devices such as smart watches and glasses are investigated in this thesis. An FHI (Fingertip Haptic Interface) was designed and built to measure the position and force resolution of the human fingertip. The thumb and forefinger resolutions were identified as 212um and 133um, respectively. The force threshold at which the forefinger detects pulses was found experimentally to be F(t) = .148t + 28.7 where t is the pulse width in ms, and F(t) is the fingertip force in mN. It was found that visual feedback dominates user input tasks, but during eyes-free usage haptic feedback provides an improvement that quickly dissipates with increased task difficulty. Finally, the smallest target size that can be reliably selected was found to be two to three times the smallest resolution of the index finger or thumb.","abstract_has_math":false,"creators":["Stobart, Christopher"],"institution":"Graduate Studies","degree_name":"Master of Science (MSc)","degree_level":null,"degree_discipline":"Mechanical and Manufacturing Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Goldsmith, Peter"],"committee_chairs":[],"committee_members":[],"year":2014,"date_issued":"2014-09-24","date_published":"2014-09-24","updated_at":"2026-11-19T07:27:50Z","subjects":["Engineering--Electronics and Electrical","Engineering--Mechanical"],"languages":["eng"],"rights":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/11023/1799"],"render_values":[{"text":"http://hdl.handle.net/11023/1799","href":"https://hdl.handle.net/11023/1799","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.11575/PRISM/25575","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.11575/PRISM/25575","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Acalgary%3Aoai%3Aucalgary.scholaris.ca%3A11023%2F1799","prefix":"oai_dc"},"source_record":{"url":"https://ucalgary.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aucalgary.scholaris.ca%3A11023%2F1799","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Goldsmith, Peter"]},{"key":"dc:creator","label":"Author","values":["Stobart, Christopher"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2014-09-24T15:40:07Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2014-11-17T08:00:47Z"]},{"key":"dc:date.issued","label":"Date","values":["2014-09-24"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["2014"]},{"key":"dc:publisher.faculty","label":"Dc Publisher Faculty","values":["Graduate Studies"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Calgary"]},{"key":"dc:publisher.place","label":"Dc Publisher Place","values":["Calgary"]},{"key":"dc:type","label":"Dc Type","values":["master thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical and Manufacturing Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MSc)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Calgary"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Engineering--Electronics and Electrical","Engineering--Mechanical"]},{"key":"dc:subject.classification","label":"Dc Subject Classification","values":["Haptic","Smart Glasses","Smart Watch","Multimodal Feedback","Ultra-mobile Interface","Force Sensitivity","Human Resolution","Smallest Key"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Stobart, C. (2014). Design and Testing of a Fingertip Haptic Interface (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca. doi:10.11575/PRISM/25575"]},{"key":"dc:identifier.doi","label":"DOI","values":["http://dx.doi.org/10.11575/PRISM/25575"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/11023/1799"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"atmire:migration.oldid","label":"Atmire Migration Oldid","values":["2599"]},{"key":"dc:description.abstract","label":"Abstract","values":["Fingertip force sensitivity threshold, human resolution, multimodal feedback, and interface miniaturization for ultra-mobile devices such as smart watches and glasses are investigated in this thesis. An FHI (Fingertip Haptic Interface) was designed and built to measure the position and force resolution of the human fingertip. The thumb and forefinger resolutions were identified as 212um and 133um, respectively. The force threshold at which the forefinger detects pulses was found experimentally to be F(t) = .148t + 28.7 where t is the pulse width in ms, and F(t) is the fingertip force in mN. It was found that visual feedback dominates user input tasks, but during eyes-free usage haptic feedback provides an improvement that quickly dissipates with increased task difficulty. Finally, the smallest target size that can be reliably selected was found to be two to three times the smallest resolution of the index finger or thumb."]},{"key":"dc:title","label":"Title","values":["Design and Testing of a Fingertip Haptic Interface"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:request.copy","label":"Local Request Copy","values":["true"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"atmire:migration.oldid":["2599"],"dc:contributor.advisor":["Goldsmith, Peter"],"dc:creator":["Stobart, Christopher"],"dc:date.accessioned":["2014-09-24T15:40:07Z"],"dc:date.available":["2014-11-17T08:00:47Z"],"dc:date.issued":["2014-09-24"],"dc:date.submitted":["2014"],"dc:description.abstract":["Fingertip force sensitivity threshold, human resolution, multimodal feedback, and interface miniaturization for ultra-mobile devices such as smart watches and glasses are investigated in this thesis. An FHI (Fingertip Haptic Interface) was designed and built to measure the position and force resolution of the human fingertip. The thumb and forefinger resolutions were identified as 212um and 133um, respectively. The force threshold at which the forefinger detects pulses was found experimentally to be F(t) = .148t + 28.7 where t is the pulse width in ms, and F(t) is the fingertip force in mN. It was found that visual feedback dominates user input tasks, but during eyes-free usage haptic feedback provides an improvement that quickly dissipates with increased task difficulty. Finally, the smallest target size that can be reliably selected was found to be two to three times the smallest resolution of the index finger or thumb."],"dc:identifier.citation":["Stobart, C. (2014). Design and Testing of a Fingertip Haptic Interface (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca. doi:10.11575/PRISM/25575"],"dc:identifier.doi":["http://dx.doi.org/10.11575/PRISM/25575"],"dc:identifier.uri":["http://hdl.handle.net/11023/1799"],"dc:language.iso":["eng"],"dc:publisher.faculty":["Graduate Studies"],"dc:publisher.institution":["University of Calgary"],"dc:publisher.place":["Calgary"],"dc:rights":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."],"dc:subject":["Engineering--Electronics and Electrical","Engineering--Mechanical"],"dc:subject.classification":["Haptic","Smart Glasses","Smart Watch","Multimodal Feedback","Ultra-mobile Interface","Force Sensitivity","Human Resolution","Smallest Key"],"dc:title":["Design and Testing of a Fingertip Haptic Interface"],"dc:type":["master thesis"],"dspace:entity.type":["Publication"],"local:request.copy":["true"],"others:access_status":["open.access"],"thesis:degree_discipline":["Mechanical and Manufacturing Engineering"],"thesis:degree_name":["Master of Science (MSc)"],"thesis:institution_name":["University of Calgary"]},"updated_at":"2026-11-19T07:27:50Z"}