{"id":{"repo_id":"calgary","oai_identifier":"oai:ucalgary.scholaris.ca:11023/1845"},"canonical_url":"https://search.ndltd.org/etd/calgary/oai:ucalgary.scholaris.ca:11023/1845","repository":{"repo_id":"calgary","name":"University of Calgary","base_url":"https://ucalgary.scholaris.ca/server/oai/request"},"display":{"title":"Monte Carlo model of the Brainlab Novalis Classic 6 MV linac using the GATE simulation platform","abstract":"Monte Carlo (MC) simulations are known to be the most accurate method to model radiation transport and absorbed dose. Geant4 application for tomographic emission (GATE) is a Monte Carlo simulation platform built and is relatively new at modeling radiotherapy systems. A MC model of the Brainlab Novalis Classic 6 MV was developed using GATE which will investigate GATE’s capabilities in the application of a stereotactic radiosurgery (SRS) dedicated linear accelerator. Measured depth dose distributions and dose profiles using an ion chamber, diode detector, and radiochromic film are used as reference measurements for the model. The model shows agreement with the measured data with greater than 90% of points passing a 3%/1mm gamma comparison, with the exception of smaller field sizes in the penumbra region which still agree within 3%/3mm. This model demonstrates GATE ability to model linacs and can be used in the future for research and clinical comparisons.","abstract_html":"Monte Carlo (MC) simulations are known to be the most accurate method to model radiation transport and absorbed dose. Geant4 application for tomographic emission (GATE) is a Monte Carlo simulation platform built and is relatively new at modeling radiotherapy systems. A MC model of the Brainlab Novalis Classic 6 MV was developed using GATE which will investigate GATE’s capabilities in the application of a stereotactic radiosurgery (SRS) dedicated linear accelerator. Measured depth dose distributions and dose profiles using an ion chamber, diode detector, and radiochromic film are used as reference measurements for the model. The model shows agreement with the measured data with greater than 90% of points passing a 3%/1mm gamma comparison, with the exception of smaller field sizes in the penumbra region which still agree within 3%/3mm. This model demonstrates GATE ability to model linacs and can be used in the future for research and clinical comparisons.","abstract_has_math":false,"creators":["Wiebe, Jared"],"institution":"Graduate Studies","degree_name":"Master of Science (MSc)","degree_level":null,"degree_discipline":"Physics and Astronomy","degree_department":null,"school":null,"contributors":[],"advisors":["Ploquin, Nicolas","Khan, Rao"],"committee_chairs":[],"committee_members":[],"year":2014,"date_issued":"2014-09-29","date_published":"2014-09-29","updated_at":"2026-11-19T07:28:39Z","subjects":["Physics--Radiation"],"languages":["eng"],"rights":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/11023/1845"],"render_values":[{"text":"http://hdl.handle.net/11023/1845","href":"https://hdl.handle.net/11023/1845","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.11575/PRISM/27004","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.11575/PRISM/27004","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Acalgary%3Aoai%3Aucalgary.scholaris.ca%3A11023%2F1845","prefix":"oai_dc"},"source_record":{"url":"https://ucalgary.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aucalgary.scholaris.ca%3A11023%2F1845","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Ploquin, Nicolas","Khan, Rao"]},{"key":"dc:creator","label":"Author","values":["Wiebe, Jared"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2014-09-29T21:20:28Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2014-11-17T08:00:50Z"]},{"key":"dc:date.issued","label":"Date","values":["2014-09-29"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["2014"]},{"key":"dc:publisher.faculty","label":"Dc Publisher Faculty","values":["Graduate Studies"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Calgary"]},{"key":"dc:publisher.place","label":"Dc Publisher Place","values":["Calgary"]},{"key":"dc:type","label":"Dc Type","values":["master thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Physics and Astronomy"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MSc)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Calgary"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Physics--Radiation"]},{"key":"dc:subject.classification","label":"Dc Subject Classification","values":["GATE","Geant4","Monte Carlo","Radiation Therapy","Novalis"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Wiebe, J. (2014). Monte Carlo model of the Brainlab Novalis Classic 6 MV linac using the GATE simulation platform (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca. doi:10.11575/PRISM/27004"]},{"key":"dc:identifier.doi","label":"DOI","values":["http://dx.doi.org/10.11575/PRISM/27004"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/11023/1845"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"atmire:migration.oldid","label":"Atmire Migration Oldid","values":["2664"]},{"key":"dc:description.abstract","label":"Abstract","values":["Monte Carlo (MC) simulations are known to be the most accurate method to model radiation transport and absorbed dose. Geant4 application for tomographic emission (GATE) is a Monte Carlo simulation platform built and is relatively new at modeling radiotherapy systems. A MC model of the Brainlab Novalis Classic 6 MV was developed using GATE which will investigate GATE’s capabilities in the application of a stereotactic radiosurgery (SRS) dedicated linear accelerator. Measured depth dose distributions and dose profiles using an ion chamber, diode detector, and radiochromic film are used as reference measurements for the model. The model shows agreement with the measured data with greater than 90% of points passing a 3%/1mm gamma comparison, with the exception of smaller field sizes in the penumbra region which still agree within 3%/3mm. This model demonstrates GATE ability to model linacs and can be used in the future for research and clinical comparisons."]},{"key":"dc:title","label":"Title","values":["Monte Carlo model of the Brainlab Novalis Classic 6 MV linac using the GATE simulation platform"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:request.copy","label":"Local Request Copy","values":["true"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"atmire:migration.oldid":["2664"],"dc:contributor.advisor":["Ploquin, Nicolas","Khan, Rao"],"dc:creator":["Wiebe, Jared"],"dc:date.accessioned":["2014-09-29T21:20:28Z"],"dc:date.available":["2014-11-17T08:00:50Z"],"dc:date.issued":["2014-09-29"],"dc:date.submitted":["2014"],"dc:description.abstract":["Monte Carlo (MC) simulations are known to be the most accurate method to model radiation transport and absorbed dose. Geant4 application for tomographic emission (GATE) is a Monte Carlo simulation platform built and is relatively new at modeling radiotherapy systems. A MC model of the Brainlab Novalis Classic 6 MV was developed using GATE which will investigate GATE’s capabilities in the application of a stereotactic radiosurgery (SRS) dedicated linear accelerator. Measured depth dose distributions and dose profiles using an ion chamber, diode detector, and radiochromic film are used as reference measurements for the model. The model shows agreement with the measured data with greater than 90% of points passing a 3%/1mm gamma comparison, with the exception of smaller field sizes in the penumbra region which still agree within 3%/3mm. This model demonstrates GATE ability to model linacs and can be used in the future for research and clinical comparisons."],"dc:identifier.citation":["Wiebe, J. (2014). Monte Carlo model of the Brainlab Novalis Classic 6 MV linac using the GATE simulation platform (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca. doi:10.11575/PRISM/27004"],"dc:identifier.doi":["http://dx.doi.org/10.11575/PRISM/27004"],"dc:identifier.uri":["http://hdl.handle.net/11023/1845"],"dc:language.iso":["eng"],"dc:publisher.faculty":["Graduate Studies"],"dc:publisher.institution":["University of Calgary"],"dc:publisher.place":["Calgary"],"dc:rights":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."],"dc:subject":["Physics--Radiation"],"dc:subject.classification":["GATE","Geant4","Monte Carlo","Radiation Therapy","Novalis"],"dc:title":["Monte Carlo model of the Brainlab Novalis Classic 6 MV linac using the GATE simulation platform"],"dc:type":["master thesis"],"dspace:entity.type":["Publication"],"local:request.copy":["true"],"others:access_status":["open.access"],"thesis:degree_discipline":["Physics and Astronomy"],"thesis:degree_name":["Master of Science (MSc)"],"thesis:institution_name":["University of Calgary"]},"updated_at":"2026-11-19T07:28:39Z"}