{"id":{"repo_id":"calgary","oai_identifier":"oai:ucalgary.scholaris.ca:11023/2085"},"canonical_url":"https://search.ndltd.org/etd/calgary/oai:ucalgary.scholaris.ca:11023/2085","repository":{"repo_id":"calgary","name":"University of Calgary","base_url":"https://ucalgary.scholaris.ca/server/oai/request"},"display":{"title":"ONLINE IDENTIFICATION AND ADAPTIVE CONTROL OF BIOLOGICAL WASTEWATER TREATMENT PROCESS","abstract":"The activated sludge process is a nonlinear, time-varying, multi-input-multi-output system. It is important to design an adaptive control strategy, which can not only track the setpoint changes quickly, but also adapt to the system uncertainties and disturbance signals. The current work presents a single-input-single-output Generalized Predictive Controller to regulate the dissolved oxygen concentration and a multi-loop Generalized Predictive Control scheme to control the dissolved oxygen concentration and the substrate concentration. The control is tested with both a simplified four-state model and an activated sludge model no. 1 (ASM1) benchmark of an activated sludge process. In the univariate algorithm, the manipulated variable (controller output) is the air flow rate (or the oxygen transfer coefficient) and the controlled variable (measured variable) is the dissolved oxygen concentration. On the other hand, for the multivariable process, two separate control loops are taken into consideration such that in the first control loop, the air flow rate (or the oxygen transfer coefficient) is used to regulate the dissolved oxygen concentration, and in the second control loop, the recycled to influent rate (or the return sludge flow rate) is used to manipulate the substrate concentration. Initially, the GPC controller is implemented in the presence of white measurement noise. In this case, an ARX model is used as the prediction model in a GPC structure. The RLS identification method estimates the parameters of this ARX model. Then, the ability of GPC controller in the presence of random walk disturbance (coloured noise together with an integral factor) is tested. In this case, a CARIMA model is used as the prediction model and an ELS identification method is used to estimate the parameters of this model. A method which can compensate the effect of coloured noise is GPC with T filter. The results of a conventional GPC controller is compared with a GPC with T filter and a PI controller.","abstract_html":"The activated sludge process is a nonlinear, time-varying, multi-input-multi-output system. It is important to design an adaptive control strategy, which can not only track the setpoint changes quickly, but also adapt to the system uncertainties and disturbance signals. The current work presents a single-input-single-output Generalized Predictive Controller to regulate the dissolved oxygen concentration and a multi-loop Generalized Predictive Control scheme to control the dissolved oxygen concentration and the substrate concentration. The control is tested with both a simplified four-state model and an activated sludge model no. 1 (ASM1) benchmark of an activated sludge process. In the univariate algorithm, the manipulated variable (controller output) is the air flow rate (or the oxygen transfer coefficient) and the controlled variable (measured variable) is the dissolved oxygen concentration. On the other hand, for the multivariable process, two separate control loops are taken into consideration such that in the first control loop, the air flow rate (or the oxygen transfer coefficient) is used to regulate the dissolved oxygen concentration, and in the second control loop, the recycled to influent rate (or the return sludge flow rate) is used to manipulate the substrate concentration. Initially, the GPC controller is implemented in the presence of white measurement noise. In this case, an ARX model is used as the prediction model in a GPC structure. The RLS identification method estimates the parameters of this ARX model. Then, the ability of GPC controller in the presence of random walk disturbance (coloured noise together with an integral factor) is tested. In this case, a CARIMA model is used as the prediction model and an ELS identification method is used to estimate the parameters of this model. A method which can compensate the effect of coloured noise is GPC with T filter. The results of a conventional GPC controller is compared with a GPC with T filter and a PI controller.","abstract_has_math":false,"creators":["SADEGHASSADI, MAHSA"],"institution":"Graduate Studies","degree_name":"Master of Science (MSc)","degree_level":null,"degree_discipline":"Electrical and Computer Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Macnab, Chris J.B","Westwick, David"],"committee_chairs":[],"committee_members":[],"year":2015,"date_issued":"2015-02-05","date_published":"2015-02-05","updated_at":"2026-11-19T07:24:07Z","subjects":["Engineering--Electronics and Electrical"],"languages":["eng"],"rights":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/11023/2085"],"render_values":[{"text":"http://hdl.handle.net/11023/2085","href":"https://hdl.handle.net/11023/2085","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.11575/PRISM/27179","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.11575/PRISM/27179","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Acalgary%3Aoai%3Aucalgary.scholaris.ca%3A11023%2F2085","prefix":"oai_dc"},"source_record":{"url":"https://ucalgary.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aucalgary.scholaris.ca%3A11023%2F2085","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Macnab, Chris J.B","Westwick, David"]},{"key":"dc:creator","label":"Author","values":["SADEGHASSADI, MAHSA"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2015-02-05T20:41:49Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2015-06-23T07:00:45Z"]},{"key":"dc:date.issued","label":"Date","values":["2015-02-05"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["2015"]},{"key":"dc:publisher.faculty","label":"Dc Publisher Faculty","values":["Graduate Studies"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Calgary"]},{"key":"dc:publisher.place","label":"Dc Publisher Place","values":["Calgary"]},{"key":"dc:type","label":"Dc Type","values":["master thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical and Computer Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MSc)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Calgary"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Engineering--Electronics and Electrical"]},{"key":"dc:subject.classification","label":"Dc Subject Classification","values":["Biological Wastewater Treatment","Generalized Predictive Control","Least-Squares Identification Method","BSM1 Benchmark"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["SADEGHASSADI, MAHSA. (2015). ONLINE IDENTIFICATION AND ADAPTIVE CONTROL OF BIOLOGICAL WASTEWATER TREATMENT PROCESS (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca. doi:10.11575/PRISM/27179"]},{"key":"dc:identifier.doi","label":"DOI","values":["http://dx.doi.org/10.11575/PRISM/27179"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/11023/2085"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"atmire:migration.oldid","label":"Atmire Migration Oldid","values":["2999"]},{"key":"dc:description.abstract","label":"Abstract","values":["The activated sludge process is a nonlinear, time-varying, multi-input-multi-output system. It is important to design an adaptive control strategy, which can not only track the setpoint changes quickly, but also adapt to the system uncertainties and disturbance signals. The current work presents a single-input-single-output Generalized Predictive Controller to regulate the dissolved oxygen concentration and a multi-loop Generalized Predictive Control scheme to control the dissolved oxygen concentration and the substrate concentration. The control is tested with both a simplified four-state model and an activated sludge model no. 1 (ASM1) benchmark of an activated sludge process. In the univariate algorithm, the manipulated variable (controller output) is the air flow rate (or the oxygen transfer coefficient) and the controlled variable (measured variable) is the dissolved oxygen concentration. On the other hand, for the multivariable process, two separate control loops are taken into consideration such that in the first control loop, the air flow rate (or the oxygen transfer coefficient) is used to regulate the dissolved oxygen concentration, and in the second control loop, the recycled to influent rate (or the return sludge flow rate) is used to manipulate the substrate concentration. Initially, the GPC controller is implemented in the presence of white measurement noise. In this case, an ARX model is used as the prediction model in a GPC structure. The RLS identification method estimates the parameters of this ARX model. Then, the ability of GPC controller in the presence of random walk disturbance (coloured noise together with an integral factor) is tested. In this case, a CARIMA model is used as the prediction model and an ELS identification method is used to estimate the parameters of this model. A method which can compensate the effect of coloured noise is GPC with T filter. The results of a conventional GPC controller is compared with a GPC with T filter and a PI controller."]},{"key":"dc:title","label":"Title","values":["ONLINE IDENTIFICATION AND ADAPTIVE CONTROL OF BIOLOGICAL WASTEWATER TREATMENT PROCESS"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:request.copy","label":"Local Request Copy","values":["true"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"atmire:migration.oldid":["2999"],"dc:contributor.advisor":["Macnab, Chris J.B","Westwick, David"],"dc:creator":["SADEGHASSADI, MAHSA"],"dc:date.accessioned":["2015-02-05T20:41:49Z"],"dc:date.available":["2015-06-23T07:00:45Z"],"dc:date.issued":["2015-02-05"],"dc:date.submitted":["2015"],"dc:description.abstract":["The activated sludge process is a nonlinear, time-varying, multi-input-multi-output system. It is important to design an adaptive control strategy, which can not only track the setpoint changes quickly, but also adapt to the system uncertainties and disturbance signals. The current work presents a single-input-single-output Generalized Predictive Controller to regulate the dissolved oxygen concentration and a multi-loop Generalized Predictive Control scheme to control the dissolved oxygen concentration and the substrate concentration. The control is tested with both a simplified four-state model and an activated sludge model no. 1 (ASM1) benchmark of an activated sludge process. In the univariate algorithm, the manipulated variable (controller output) is the air flow rate (or the oxygen transfer coefficient) and the controlled variable (measured variable) is the dissolved oxygen concentration. On the other hand, for the multivariable process, two separate control loops are taken into consideration such that in the first control loop, the air flow rate (or the oxygen transfer coefficient) is used to regulate the dissolved oxygen concentration, and in the second control loop, the recycled to influent rate (or the return sludge flow rate) is used to manipulate the substrate concentration. Initially, the GPC controller is implemented in the presence of white measurement noise. In this case, an ARX model is used as the prediction model in a GPC structure. The RLS identification method estimates the parameters of this ARX model. Then, the ability of GPC controller in the presence of random walk disturbance (coloured noise together with an integral factor) is tested. In this case, a CARIMA model is used as the prediction model and an ELS identification method is used to estimate the parameters of this model. A method which can compensate the effect of coloured noise is GPC with T filter. The results of a conventional GPC controller is compared with a GPC with T filter and a PI controller."],"dc:identifier.citation":["SADEGHASSADI, MAHSA. (2015). ONLINE IDENTIFICATION AND ADAPTIVE CONTROL OF BIOLOGICAL WASTEWATER TREATMENT PROCESS (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca. doi:10.11575/PRISM/27179"],"dc:identifier.doi":["http://dx.doi.org/10.11575/PRISM/27179"],"dc:identifier.uri":["http://hdl.handle.net/11023/2085"],"dc:language.iso":["eng"],"dc:publisher.faculty":["Graduate Studies"],"dc:publisher.institution":["University of Calgary"],"dc:publisher.place":["Calgary"],"dc:rights":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."],"dc:subject":["Engineering--Electronics and Electrical"],"dc:subject.classification":["Biological Wastewater Treatment","Generalized Predictive Control","Least-Squares Identification Method","BSM1 Benchmark"],"dc:title":["ONLINE IDENTIFICATION AND ADAPTIVE CONTROL OF BIOLOGICAL WASTEWATER TREATMENT PROCESS"],"dc:type":["master thesis"],"dspace:entity.type":["Publication"],"local:request.copy":["true"],"others:access_status":["open.access"],"thesis:degree_discipline":["Electrical and Computer Engineering"],"thesis:degree_name":["Master of Science (MSc)"],"thesis:institution_name":["University of Calgary"]},"updated_at":"2026-11-19T07:24:07Z"}