{"id":{"repo_id":"calgary","oai_identifier":"oai:ucalgary.scholaris.ca:11023/2155"},"canonical_url":"https://search.ndltd.org/etd/calgary/oai:ucalgary.scholaris.ca:11023/2155","repository":{"repo_id":"calgary","name":"University of Calgary","base_url":"https://ucalgary.scholaris.ca/server/oai/request"},"display":{"title":"Design, Construction, and Calibration of a Vibrating Tube Densimeter for Volumetric Measurements of Acid Gas Fluids","abstract":"Volumetric changes are vital to understanding the high-pressure chemical thermodynamics within acid gas injection processes. In this study, a vibrating tube densimeter was constructed and calibrated in order to perform volumetric measurements on acid gas fluids where previous literature were sparse. The densimeter uses an optically coupled feedback loop in order to maintain a fluid filled vibrating tube at its harmonic frequency. The densimeter is capable of measuring densities at temperatures between T = 25 and 150 °C and pressures up to p = 35 MPa (5076 psia). Densities of pure carbon dioxide and water dissolved in carbon dioxide at low concentrations were measured and used to calculate partial molar volumes at temperatures between T = 45 and 120 °C and pressures up to p = 35 MPa for use in equilibrium or fugacity calculations. The Krichevskii parameter for water’s influence on carbon dioxide’s critical behaviour was determined using the partial molar volume measurements.","abstract_html":"Volumetric changes are vital to understanding the high-pressure chemical thermodynamics within acid gas injection processes. In this study, a vibrating tube densimeter was constructed and calibrated in order to perform volumetric measurements on acid gas fluids where previous literature were sparse. The densimeter uses an optically coupled feedback loop in order to maintain a fluid filled vibrating tube at its harmonic frequency. The densimeter is capable of measuring densities at temperatures between T = 25 and 150 °C and pressures up to p = 35 MPa (5076 psia). Densities of pure carbon dioxide and water dissolved in carbon dioxide at low concentrations were measured and used to calculate partial molar volumes at temperatures between T = 45 and 120 °C and pressures up to p = 35 MPa for use in equilibrium or fugacity calculations. The Krichevskii parameter for water’s influence on carbon dioxide’s critical behaviour was determined using the partial molar volume measurements.","abstract_has_math":false,"creators":["Deering, Connor Edward"],"institution":"Graduate Studies","degree_name":"Master of Science (MSc)","degree_level":null,"degree_discipline":"Chemistry","degree_department":null,"school":null,"contributors":[],"advisors":["Marriott, Dr. Robert"],"committee_chairs":[],"committee_members":[],"year":2015,"date_issued":"2015-04-22","date_published":"2015-04-22","updated_at":"2026-11-19T07:28:50Z","subjects":["Chemistry--Analytical","Chemistry--Physical","Engineering--Chemical"],"languages":["eng"],"rights":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.doi","label":"DOI","values":["http://dx.doi.org/10.11575/PRISM/25578"],"render_values":[{"text":"http://dx.doi.org/10.11575/PRISM/25578","href":"http://dx.doi.org/10.11575/PRISM/25578","code":true}]},{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Deering, C. E. (2015). Design, Construction, and Calibration of a Vibrating Tube Densimeter for Volumetric Measurements of Acid Gas Fluids (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca. doi:10.11575/PRISM/25578"],"render_values":[{"text":"Deering, C. E. (2015). Design, Construction, and Calibration of a Vibrating Tube Densimeter for Volumetric Measurements of Acid Gas Fluids (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca. doi:10.11575/PRISM/25578","href":"https://doi.org/10.11575/PRISM/25578","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/11023/2155","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/11023/2155","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://ucalgary.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aucalgary.scholaris.ca%3A11023%2F2155","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Marriott, Dr. Robert"]},{"key":"dc:creator","label":"Author","values":["Deering, Connor Edward"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2015-04-22T18:19:27Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2015-06-22T07:00:44Z"]},{"key":"dc:date.issued","label":"Date","values":["2015-04-22"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["2015"]},{"key":"dc:publisher.faculty","label":"Dc Publisher Faculty","values":["Graduate Studies"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Calgary"]},{"key":"dc:publisher.place","label":"Dc Publisher Place","values":["Calgary"]},{"key":"dc:type","label":"Dc Type","values":["master thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Chemistry"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MSc)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Calgary"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Chemistry--Analytical","Chemistry--Physical","Engineering--Chemical"]},{"key":"dc:subject.classification","label":"Dc Subject Classification","values":["Vibrating Tube Densimetry","Density","Carbon Dioxide","Water","Volumetric Properties","Krichevskii Parameter","Acid Gas Injection","Experimental Thermodynamics","Physical Chemistry","Analytical Chemistry","Supercritical Fluids","High-Pressure Fluids"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Deering, C. E. (2015). Design, Construction, and Calibration of a Vibrating Tube Densimeter for Volumetric Measurements of Acid Gas Fluids (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca. doi:10.11575/PRISM/25578"]},{"key":"dc:identifier.doi","label":"DOI","values":["http://dx.doi.org/10.11575/PRISM/25578"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/11023/2155"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"atmire:migration.oldid","label":"Atmire Migration Oldid","values":["3076"]},{"key":"dc:description.abstract","label":"Abstract","values":["Volumetric changes are vital to understanding the high-pressure chemical thermodynamics within acid gas injection processes. In this study, a vibrating tube densimeter was constructed and calibrated in order to perform volumetric measurements on acid gas fluids where previous literature were sparse. The densimeter uses an optically coupled feedback loop in order to maintain a fluid filled vibrating tube at its harmonic frequency. The densimeter is capable of measuring densities at temperatures between T = 25 and 150 °C and pressures up to p = 35 MPa (5076 psia). Densities of pure carbon dioxide and water dissolved in carbon dioxide at low concentrations were measured and used to calculate partial molar volumes at temperatures between T = 45 and 120 °C and pressures up to p = 35 MPa for use in equilibrium or fugacity calculations. The Krichevskii parameter for water’s influence on carbon dioxide’s critical behaviour was determined using the partial molar volume measurements."]},{"key":"dc:title","label":"Title","values":["Design, Construction, and Calibration of a Vibrating Tube Densimeter for Volumetric Measurements of Acid Gas Fluids"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:request.copy","label":"Local Request Copy","values":["true"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"atmire:migration.oldid":["3076"],"dc:contributor.advisor":["Marriott, Dr. Robert"],"dc:creator":["Deering, Connor Edward"],"dc:date.accessioned":["2015-04-22T18:19:27Z"],"dc:date.available":["2015-06-22T07:00:44Z"],"dc:date.issued":["2015-04-22"],"dc:date.submitted":["2015"],"dc:description.abstract":["Volumetric changes are vital to understanding the high-pressure chemical thermodynamics within acid gas injection processes. In this study, a vibrating tube densimeter was constructed and calibrated in order to perform volumetric measurements on acid gas fluids where previous literature were sparse. The densimeter uses an optically coupled feedback loop in order to maintain a fluid filled vibrating tube at its harmonic frequency. The densimeter is capable of measuring densities at temperatures between T = 25 and 150 °C and pressures up to p = 35 MPa (5076 psia). Densities of pure carbon dioxide and water dissolved in carbon dioxide at low concentrations were measured and used to calculate partial molar volumes at temperatures between T = 45 and 120 °C and pressures up to p = 35 MPa for use in equilibrium or fugacity calculations. The Krichevskii parameter for water’s influence on carbon dioxide’s critical behaviour was determined using the partial molar volume measurements."],"dc:identifier.citation":["Deering, C. E. (2015). Design, Construction, and Calibration of a Vibrating Tube Densimeter for Volumetric Measurements of Acid Gas Fluids (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca. doi:10.11575/PRISM/25578"],"dc:identifier.doi":["http://dx.doi.org/10.11575/PRISM/25578"],"dc:identifier.uri":["http://hdl.handle.net/11023/2155"],"dc:language.iso":["eng"],"dc:publisher.faculty":["Graduate Studies"],"dc:publisher.institution":["University of Calgary"],"dc:publisher.place":["Calgary"],"dc:rights":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."],"dc:subject":["Chemistry--Analytical","Chemistry--Physical","Engineering--Chemical"],"dc:subject.classification":["Vibrating Tube Densimetry","Density","Carbon Dioxide","Water","Volumetric Properties","Krichevskii Parameter","Acid Gas Injection","Experimental Thermodynamics","Physical Chemistry","Analytical Chemistry","Supercritical Fluids","High-Pressure Fluids"],"dc:title":["Design, Construction, and Calibration of a Vibrating Tube Densimeter for Volumetric Measurements of Acid Gas Fluids"],"dc:type":["master thesis"],"dspace:entity.type":["Publication"],"local:request.copy":["true"],"others:access_status":["open.access"],"thesis:degree_discipline":["Chemistry"],"thesis:degree_name":["Master of Science (MSc)"],"thesis:institution_name":["University of Calgary"]},"updated_at":"2026-11-19T07:28:50Z"}