{"id":{"repo_id":"calgary","oai_identifier":"oai:ucalgary.scholaris.ca:11023/2593"},"canonical_url":"https://search.ndltd.org/etd/calgary/oai:ucalgary.scholaris.ca:11023/2593","repository":{"repo_id":"calgary","name":"University of Calgary","base_url":"https://ucalgary.scholaris.ca/server/oai/request"},"display":{"title":"Wind Flow over Small Buildings for Renewable Energy Applications","abstract":"The wind flow over three buildings is simulated and presented for different wind directions using the standard k-ε turbulence model. The main purposes are, first, to predict the minimum wind load regions on roof mounted photovoltaic modules for reducing the cost of installing them on a mono-slope roof building. Secondly, to predict the flow fields along the gable of a tent roof building for analysis of the performance of a transverse axis wind turbine along the gable. The results for the cube simulation are compared with the experimental and other CFD results for validating the CFD. The present research provides the best locations for roof mounted PV modules. These results were significantly lower in magnitude than the NBCC values. The flow fields over the tent roof building were predicted and consistent with the field data. The flow over buildings was highly dependent on the building orientation and geometry.","abstract_html":"The wind flow over three buildings is simulated and presented for different wind directions using the standard k-ε turbulence model. The main purposes are, first, to predict the minimum wind load regions on roof mounted photovoltaic modules for reducing the cost of installing them on a mono-slope roof building. Secondly, to predict the flow fields along the gable of a tent roof building for analysis of the performance of a transverse axis wind turbine along the gable. The results for the cube simulation are compared with the experimental and other CFD results for validating the CFD. The present research provides the best locations for roof mounted PV modules. These results were significantly lower in magnitude than the NBCC values. The flow fields over the tent roof building were predicted and consistent with the field data. The flow over buildings was highly dependent on the building orientation and geometry.","abstract_has_math":false,"creators":["REZA, MD. SHAMIM"],"institution":"Graduate Studies","degree_name":"Master of Science (MSc)","degree_level":null,"degree_discipline":"Mechanical and Manufacturing Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Wood, David"],"committee_chairs":[],"committee_members":[],"year":2015,"date_issued":"2015-10-02","date_published":"2015-10-02","updated_at":"2026-11-19T07:36:49Z","subjects":["Energy","Engineering--Mechanical"],"languages":["eng"],"rights":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/11023/2593"],"render_values":[{"text":"http://hdl.handle.net/11023/2593","href":"https://hdl.handle.net/11023/2593","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.11575/PRISM/28712","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.11575/PRISM/28712","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Acalgary%3Aoai%3Aucalgary.scholaris.ca%3A11023%2F2593","prefix":"oai_dc"},"source_record":{"url":"https://ucalgary.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aucalgary.scholaris.ca%3A11023%2F2593","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Wood, David"]},{"key":"dc:creator","label":"Author","values":["REZA, MD. SHAMIM"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2015-10-02T17:39:30Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2015-11-20T08:00:44Z"]},{"key":"dc:date.issued","label":"Date","values":["2015-10-02"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["2015"]},{"key":"dc:publisher.faculty","label":"Dc Publisher Faculty","values":["Graduate Studies"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Calgary"]},{"key":"dc:publisher.place","label":"Dc Publisher Place","values":["Calgary"]},{"key":"dc:type","label":"Dc Type","values":["master thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical and Manufacturing Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MSc)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Calgary"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Energy","Engineering--Mechanical"]},{"key":"dc:subject.classification","label":"Dc Subject Classification","values":["CFD, Photovoltaic Modules, Pressure Coefficient, Renewable Energy, Wind Turbine"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["REZA, MD. SHAMIM. (2015). Wind Flow over Small Buildings for Renewable Energy Applications (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca. doi:10.11575/PRISM/28712"]},{"key":"dc:identifier.doi","label":"DOI","values":["http://dx.doi.org/10.11575/PRISM/28712"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/11023/2593"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"atmire:migration.oldid","label":"Atmire Migration Oldid","values":["3766"]},{"key":"dc:description.abstract","label":"Abstract","values":["The wind flow over three buildings is simulated and presented for different wind directions using the standard k-ε turbulence model. The main purposes are, first, to predict the minimum wind load regions on roof mounted photovoltaic modules for reducing the cost of installing them on a mono-slope roof building. Secondly, to predict the flow fields along the gable of a tent roof building for analysis of the performance of a transverse axis wind turbine along the gable. The results for the cube simulation are compared with the experimental and other CFD results for validating the CFD. The present research provides the best locations for roof mounted PV modules. These results were significantly lower in magnitude than the NBCC values. The flow fields over the tent roof building were predicted and consistent with the field data. The flow over buildings was highly dependent on the building orientation and geometry."]},{"key":"dc:title","label":"Title","values":["Wind Flow over Small Buildings for Renewable Energy Applications"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:request.copy","label":"Local Request Copy","values":["true"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"atmire:migration.oldid":["3766"],"dc:contributor.advisor":["Wood, David"],"dc:creator":["REZA, MD. SHAMIM"],"dc:date.accessioned":["2015-10-02T17:39:30Z"],"dc:date.available":["2015-11-20T08:00:44Z"],"dc:date.issued":["2015-10-02"],"dc:date.submitted":["2015"],"dc:description.abstract":["The wind flow over three buildings is simulated and presented for different wind directions using the standard k-ε turbulence model. The main purposes are, first, to predict the minimum wind load regions on roof mounted photovoltaic modules for reducing the cost of installing them on a mono-slope roof building. Secondly, to predict the flow fields along the gable of a tent roof building for analysis of the performance of a transverse axis wind turbine along the gable. The results for the cube simulation are compared with the experimental and other CFD results for validating the CFD. The present research provides the best locations for roof mounted PV modules. These results were significantly lower in magnitude than the NBCC values. The flow fields over the tent roof building were predicted and consistent with the field data. The flow over buildings was highly dependent on the building orientation and geometry."],"dc:identifier.citation":["REZA, MD. SHAMIM. (2015). Wind Flow over Small Buildings for Renewable Energy Applications (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca. doi:10.11575/PRISM/28712"],"dc:identifier.doi":["http://dx.doi.org/10.11575/PRISM/28712"],"dc:identifier.uri":["http://hdl.handle.net/11023/2593"],"dc:language.iso":["eng"],"dc:publisher.faculty":["Graduate Studies"],"dc:publisher.institution":["University of Calgary"],"dc:publisher.place":["Calgary"],"dc:rights":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."],"dc:subject":["Energy","Engineering--Mechanical"],"dc:subject.classification":["CFD, Photovoltaic Modules, Pressure Coefficient, Renewable Energy, Wind Turbine"],"dc:title":["Wind Flow over Small Buildings for Renewable Energy Applications"],"dc:type":["master thesis"],"dspace:entity.type":["Publication"],"local:request.copy":["true"],"others:access_status":["open.access"],"thesis:degree_discipline":["Mechanical and Manufacturing Engineering"],"thesis:degree_name":["Master of Science (MSc)"],"thesis:institution_name":["University of Calgary"]},"updated_at":"2026-11-19T07:36:49Z"}