{"id":{"repo_id":"calgary","oai_identifier":"oai:ucalgary.scholaris.ca:11023/2754"},"canonical_url":"https://search.ndltd.org/etd/calgary/oai:ucalgary.scholaris.ca:11023/2754","repository":{"repo_id":"calgary","name":"University of Calgary","base_url":"https://ucalgary.scholaris.ca/server/oai/request"},"display":{"title":"Development and characterization of a synthetic bone analogue for surgical training","abstract":"Spinal surgeries often require screws to be placed through small cylindrical pedicles in the vertebra, beside the spinal cord, to anchor rods for spinal fusion and correction. More experienced surgeons have fewer malplaced pedicle screws. In the current training paradigm, residents primarily learn the procedure on live patients. The objective of this research was to create a synthetic bone analogue with realistic tactile feedback to improve resident training. Forces encountered during pedicle cannulation and breaching were measured ex vivo. These were used to create a cost-effective bone model that replicated the forces as well as specific heterogeneous features of bone, distinct from current bone models. Of six residents who used the new bone analogues, five had fewer breaches in the simulated environment after practice than before.","abstract_html":"Spinal surgeries often require screws to be placed through small cylindrical pedicles in the vertebra, beside the spinal cord, to anchor rods for spinal fusion and correction. More experienced surgeons have fewer malplaced pedicle screws. In the current training paradigm, residents primarily learn the procedure on live patients. The objective of this research was to create a synthetic bone analogue with realistic tactile feedback to improve resident training. Forces encountered during pedicle cannulation and breaching were measured ex vivo. These were used to create a cost-effective bone model that replicated the forces as well as specific heterogeneous features of bone, distinct from current bone models. Of six residents who used the new bone analogues, five had fewer breaches in the simulated environment after practice than before.","abstract_has_math":false,"creators":["Blair-Pattison, Aubrey"],"institution":"Graduate Studies","degree_name":"Master of Science (MSc)","degree_level":null,"degree_discipline":"Biomedical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Anglin, Carolyn"],"committee_chairs":[],"committee_members":["Anglin, Carolyn","Ramirez-Serrano, Alejandro","Di Martino, Elena","Boyd, Steven K.","Hu, Richard W"],"year":2016,"date_issued":"2016-01-18","date_published":"2016-01-18","updated_at":"2026-11-19T07:25:10Z","subjects":["Engineering--Biomedical"],"languages":["eng"],"rights":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/11023/2754"],"render_values":[{"text":"http://hdl.handle.net/11023/2754","href":"https://hdl.handle.net/11023/2754","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.11575/PRISM/25638","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.11575/PRISM/25638","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Acalgary%3Aoai%3Aucalgary.scholaris.ca%3A11023%2F2754","prefix":"oai_dc"},"source_record":{"url":"https://ucalgary.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aucalgary.scholaris.ca%3A11023%2F2754","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Anglin, Carolyn"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Anglin, Carolyn","Ramirez-Serrano, Alejandro","Di Martino, Elena","Boyd, Steven K.","Hu, Richard W"]},{"key":"dc:creator","label":"Author","values":["Blair-Pattison, Aubrey"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2016-01-18T18:09:20Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2016-01-18T18:09:20Z"]},{"key":"dc:date.issued","label":"Date","values":["2016-01-18"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["2016"]},{"key":"dc:publisher.faculty","label":"Dc Publisher Faculty","values":["Graduate Studies"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Calgary"]},{"key":"dc:publisher.place","label":"Dc Publisher Place","values":["Calgary"]},{"key":"dc:type","label":"Dc Type","values":["master thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MSc)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Calgary"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Engineering--Biomedical"]},{"key":"dc:subject.classification","label":"Dc Subject Classification","values":["spine","orthopaedic","material"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Blair-Pattison, A. (2016). Development and characterization of a synthetic bone analogue for surgical training (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca. doi:10.11575/PRISM/25638"]},{"key":"dc:identifier.doi","label":"DOI","values":["http://dx.doi.org/10.11575/PRISM/25638"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/11023/2754"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"atmire:migration.oldid","label":"Atmire Migration Oldid","values":["4007"]},{"key":"dc:description.abstract","label":"Abstract","values":["Spinal surgeries often require screws to be placed through small cylindrical pedicles in the vertebra, beside the spinal cord, to anchor rods for spinal fusion and correction. More experienced surgeons have fewer malplaced pedicle screws. In the current training paradigm, residents primarily learn the procedure on live patients. The objective of this research was to create a synthetic bone analogue with realistic tactile feedback to improve resident training. Forces encountered during pedicle cannulation and breaching were measured ex vivo. These were used to create a cost-effective bone model that replicated the forces as well as specific heterogeneous features of bone, distinct from current bone models. Of six residents who used the new bone analogues, five had fewer breaches in the simulated environment after practice than before."]},{"key":"dc:title","label":"Title","values":["Development and characterization of a synthetic bone analogue for surgical training"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:request.copy","label":"Local Request Copy","values":["true"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"atmire:migration.oldid":["4007"],"dc:contributor.advisor":["Anglin, Carolyn"],"dc:contributor.committeemember":["Anglin, Carolyn","Ramirez-Serrano, Alejandro","Di Martino, Elena","Boyd, Steven K.","Hu, Richard W"],"dc:creator":["Blair-Pattison, Aubrey"],"dc:date.accessioned":["2016-01-18T18:09:20Z"],"dc:date.available":["2016-01-18T18:09:20Z"],"dc:date.issued":["2016-01-18"],"dc:date.submitted":["2016"],"dc:description.abstract":["Spinal surgeries often require screws to be placed through small cylindrical pedicles in the vertebra, beside the spinal cord, to anchor rods for spinal fusion and correction. More experienced surgeons have fewer malplaced pedicle screws. In the current training paradigm, residents primarily learn the procedure on live patients. The objective of this research was to create a synthetic bone analogue with realistic tactile feedback to improve resident training. Forces encountered during pedicle cannulation and breaching were measured ex vivo. These were used to create a cost-effective bone model that replicated the forces as well as specific heterogeneous features of bone, distinct from current bone models. Of six residents who used the new bone analogues, five had fewer breaches in the simulated environment after practice than before."],"dc:identifier.citation":["Blair-Pattison, A. (2016). Development and characterization of a synthetic bone analogue for surgical training (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca. doi:10.11575/PRISM/25638"],"dc:identifier.doi":["http://dx.doi.org/10.11575/PRISM/25638"],"dc:identifier.uri":["http://hdl.handle.net/11023/2754"],"dc:language.iso":["eng"],"dc:publisher.faculty":["Graduate Studies"],"dc:publisher.institution":["University of Calgary"],"dc:publisher.place":["Calgary"],"dc:rights":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."],"dc:subject":["Engineering--Biomedical"],"dc:subject.classification":["spine","orthopaedic","material"],"dc:title":["Development and characterization of a synthetic bone analogue for surgical training"],"dc:type":["master thesis"],"dspace:entity.type":["Publication"],"local:request.copy":["true"],"others:access_status":["open.access"],"thesis:degree_discipline":["Biomedical Engineering"],"thesis:degree_name":["Master of Science (MSc)"],"thesis:institution_name":["University of Calgary"]},"updated_at":"2026-11-19T07:25:10Z"}