{"id":{"repo_id":"calgary","oai_identifier":"oai:ucalgary.scholaris.ca:11023/2827"},"canonical_url":"https://search.ndltd.org/etd/calgary/oai:ucalgary.scholaris.ca:11023/2827","repository":{"repo_id":"calgary","name":"University of Calgary","base_url":"https://ucalgary.scholaris.ca/server/oai/request"},"display":{"title":"Development and Characterization of an LED-Based Light Source for High-Speed Schlieren Imaging","abstract":"This work investigates the viability of using a cost effective, 623 nm light emitting diode (LED) based light source for high-speed schlieren imaging. The pulser circuit used to drive the LED was characterized on the basis of input response, pulse train characteristics, and pulse energies. Relative brightness data was measured with a photodiode and further examined within a schlieren system. Flow images of decaying, cylindrical shocks were obtained with the LED system and benchmarked against a high intensity discharge (HID) lamp. It was found that the LED could be overdriven up to 20 times the rated current while generating down to 100 ns pulses at up to a 1 MHz repetition rate. Moreover, although the LED system produced higher signals and reduced exposure times, similar image detail was observed for each light source. However, the LED exhibited a distinct advantage over the HID lamp in terms of image blur.","abstract_html":"This work investigates the viability of using a cost effective, 623 nm light emitting diode (LED) based light source for high-speed schlieren imaging. The pulser circuit used to drive the LED was characterized on the basis of input response, pulse train characteristics, and pulse energies. Relative brightness data was measured with a photodiode and further examined within a schlieren system. Flow images of decaying, cylindrical shocks were obtained with the LED system and benchmarked against a high intensity discharge (HID) lamp. It was found that the LED could be overdriven up to 20 times the rated current while generating down to 100 ns pulses at up to a 1 MHz repetition rate. Moreover, although the LED system produced higher signals and reduced exposure times, similar image detail was observed for each light source. However, the LED exhibited a distinct advantage over the HID lamp in terms of image blur.","abstract_has_math":false,"creators":["Lincoln, Daniel"],"institution":"Graduate Studies","degree_name":"Master of Science (MSc)","degree_level":null,"degree_discipline":"Mechanical and Manufacturing Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Johansen, Craig","Murari, Kartikeya"],"committee_chairs":[],"committee_members":["De Visscher, Alex","Morton, Chris","Wood, David"],"year":2016,"date_issued":"2016-02-03","date_published":"2016-02-03","updated_at":"2026-11-19T07:24:28Z","subjects":["Optics","Engineering--Aerospace"],"languages":["eng"],"rights":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/11023/2827"],"render_values":[{"text":"http://hdl.handle.net/11023/2827","href":"https://hdl.handle.net/11023/2827","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.11575/PRISM/25637","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.11575/PRISM/25637","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Acalgary%3Aoai%3Aucalgary.scholaris.ca%3A11023%2F2827","prefix":"oai_dc"},"source_record":{"url":"https://ucalgary.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aucalgary.scholaris.ca%3A11023%2F2827","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Johansen, Craig","Murari, Kartikeya"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["De Visscher, Alex","Morton, Chris","Wood, David"]},{"key":"dc:creator","label":"Author","values":["Lincoln, Daniel"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2016-02-03T19:10:23Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2016-02-03T19:10:23Z"]},{"key":"dc:date.issued","label":"Date","values":["2016-02-03"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["2016"]},{"key":"dc:publisher.faculty","label":"Dc Publisher Faculty","values":["Graduate Studies"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Calgary"]},{"key":"dc:publisher.place","label":"Dc Publisher Place","values":["Calgary"]},{"key":"dc:type","label":"Dc Type","values":["master thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical and Manufacturing Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MSc)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Calgary"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Optics","Engineering--Aerospace"]},{"key":"dc:subject.classification","label":"Dc Subject Classification","values":["Schlieren imaging","Cylindrical shock waves","Light-emitting diode (LED)","High-intensity discharge (HID) lamp"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Lincoln, D. (2016). Development and Characterization of an LED-Based Light Source for High-Speed Schlieren Imaging (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca. doi:10.11575/PRISM/25637"]},{"key":"dc:identifier.doi","label":"DOI","values":["http://dx.doi.org/10.11575/PRISM/25637"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/11023/2827"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"atmire:migration.oldid","label":"Atmire Migration Oldid","values":["4045"]},{"key":"dc:description.abstract","label":"Abstract","values":["This work investigates the viability of using a cost effective, 623 nm light emitting diode (LED) based light source for high-speed schlieren imaging. The pulser circuit used to drive the LED was characterized on the basis of input response, pulse train characteristics, and pulse energies. Relative brightness data was measured with a photodiode and further examined within a schlieren system. Flow images of decaying, cylindrical shocks were obtained with the LED system and benchmarked against a high intensity discharge (HID) lamp. It was found that the LED could be overdriven up to 20 times the rated current while generating down to 100 ns pulses at up to a 1 MHz repetition rate. Moreover, although the LED system produced higher signals and reduced exposure times, similar image detail was observed for each light source. However, the LED exhibited a distinct advantage over the HID lamp in terms of image blur."]},{"key":"dc:title","label":"Title","values":["Development and Characterization of an LED-Based Light Source for High-Speed Schlieren Imaging"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:request.copy","label":"Local Request Copy","values":["true"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"atmire:migration.oldid":["4045"],"dc:contributor.advisor":["Johansen, Craig","Murari, Kartikeya"],"dc:contributor.committeemember":["De Visscher, Alex","Morton, Chris","Wood, David"],"dc:creator":["Lincoln, Daniel"],"dc:date.accessioned":["2016-02-03T19:10:23Z"],"dc:date.available":["2016-02-03T19:10:23Z"],"dc:date.issued":["2016-02-03"],"dc:date.submitted":["2016"],"dc:description.abstract":["This work investigates the viability of using a cost effective, 623 nm light emitting diode (LED) based light source for high-speed schlieren imaging. The pulser circuit used to drive the LED was characterized on the basis of input response, pulse train characteristics, and pulse energies. Relative brightness data was measured with a photodiode and further examined within a schlieren system. Flow images of decaying, cylindrical shocks were obtained with the LED system and benchmarked against a high intensity discharge (HID) lamp. It was found that the LED could be overdriven up to 20 times the rated current while generating down to 100 ns pulses at up to a 1 MHz repetition rate. Moreover, although the LED system produced higher signals and reduced exposure times, similar image detail was observed for each light source. However, the LED exhibited a distinct advantage over the HID lamp in terms of image blur."],"dc:identifier.citation":["Lincoln, D. (2016). Development and Characterization of an LED-Based Light Source for High-Speed Schlieren Imaging (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca. doi:10.11575/PRISM/25637"],"dc:identifier.doi":["http://dx.doi.org/10.11575/PRISM/25637"],"dc:identifier.uri":["http://hdl.handle.net/11023/2827"],"dc:language.iso":["eng"],"dc:publisher.faculty":["Graduate Studies"],"dc:publisher.institution":["University of Calgary"],"dc:publisher.place":["Calgary"],"dc:rights":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."],"dc:subject":["Optics","Engineering--Aerospace"],"dc:subject.classification":["Schlieren imaging","Cylindrical shock waves","Light-emitting diode (LED)","High-intensity discharge (HID) lamp"],"dc:title":["Development and Characterization of an LED-Based Light Source for High-Speed Schlieren Imaging"],"dc:type":["master thesis"],"dspace:entity.type":["Publication"],"local:request.copy":["true"],"others:access_status":["open.access"],"thesis:degree_discipline":["Mechanical and Manufacturing Engineering"],"thesis:degree_name":["Master of Science (MSc)"],"thesis:institution_name":["University of Calgary"]},"updated_at":"2026-11-19T07:24:28Z"}