{"id":{"repo_id":"calgary","oai_identifier":"oai:ucalgary.scholaris.ca:11023/3020"},"canonical_url":"https://search.ndltd.org/etd/calgary/oai:ucalgary.scholaris.ca:11023/3020","repository":{"repo_id":"calgary","name":"University of Calgary","base_url":"https://ucalgary.scholaris.ca/server/oai/request"},"display":{"title":"Compact Optical Sensing Systems for pH and Other Substances Detection - Theory and Implementation","abstract":"Chemical detection is of importance in research and industry. Optical sensors based on contact imaging realize the chemical detection in compact, efficient and inexpensive ways. In the first project real-time optical pH sensor based on complementary metal–oxide–semiconductor (CMOS) contact imaging and microfluidics, an optical contact imaging sensor for pH detection with capillary microfluidics is proposed. The CMOS array detects the changes of light intensity after absorption by phenol red doped sol-gel filters while the level of absorbance corresponds to a pH value of the analyte. Deposition methods of sol-gel are optimized and compared. In the second project, real-time optical concentration sensor based on Raman scattering, CMOS contact imaging is presented. This biochemical optical sensor is designed for detecting the concentration of solutions. It is built with a laser diode, an optical filter, a sample holder and a commercial CMOS sensor.","abstract_html":"Chemical detection is of importance in research and industry. Optical sensors based on contact imaging realize the chemical detection in compact, efficient and inexpensive ways. In the first project real-time optical pH sensor based on complementary metal–oxide–semiconductor (CMOS) contact imaging and microfluidics, an optical contact imaging sensor for pH detection with capillary microfluidics is proposed. The CMOS array detects the changes of light intensity after absorption by phenol red doped sol-gel filters while the level of absorbance corresponds to a pH value of the analyte. Deposition methods of sol-gel are optimized and compared. In the second project, real-time optical concentration sensor based on Raman scattering, CMOS contact imaging is presented. This biochemical optical sensor is designed for detecting the concentration of solutions. It is built with a laser diode, an optical filter, a sample holder and a commercial CMOS sensor.","abstract_has_math":false,"creators":["Cao, Muyun"],"institution":"Graduate Studies","degree_name":"Master of Science (MSc)","degree_level":null,"degree_discipline":"Electrical and Computer Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Yadid-Pecht, Orly"],"committee_chairs":[],"committee_members":["Yadid-Pecht, Orly","Murari, Kartikeya","Chodavarapu, Vamsy"],"year":2016,"date_issued":"2016","date_published":"2016","updated_at":"2026-11-19T07:11:00Z","subjects":["Engineering--Electronics and Electrical"],"languages":["eng"],"rights":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/11023/3020"],"render_values":[{"text":"http://hdl.handle.net/11023/3020","href":"https://hdl.handle.net/11023/3020","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.11575/PRISM/25367","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.11575/PRISM/25367","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Acalgary%3Aoai%3Aucalgary.scholaris.ca%3A11023%2F3020","prefix":"oai_dc"},"source_record":{"url":"https://ucalgary.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aucalgary.scholaris.ca%3A11023%2F3020","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Yadid-Pecht, Orly"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Yadid-Pecht, Orly","Murari, Kartikeya","Chodavarapu, Vamsy"]},{"key":"dc:creator","label":"Author","values":["Cao, Muyun"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2016-05-17T20:40:45Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2016-05-17T20:40:45Z"]},{"key":"dc:date.issued","label":"Date","values":["2016"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["2016"]},{"key":"dc:publisher.faculty","label":"Dc Publisher Faculty","values":["Graduate Studies"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Calgary"]},{"key":"dc:publisher.place","label":"Dc Publisher Place","values":["Calgary"]},{"key":"dc:type","label":"Dc Type","values":["master thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical and Computer Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MSc)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Calgary"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Engineering--Electronics and Electrical"]},{"key":"dc:subject.classification","label":"Dc Subject Classification","values":["Sensor","optical","Chemical","CMOS","pH"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Cao, M. (2016). Compact Optical Sensing Systems for pH and Other Substances Detection - Theory and Implementation (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca. doi:10.11575/PRISM/25367"]},{"key":"dc:identifier.doi","label":"DOI","values":["http://dx.doi.org/10.11575/PRISM/25367"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/11023/3020"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"atmire:migration.oldid","label":"Atmire Migration Oldid","values":["4447"]},{"key":"dc:description.abstract","label":"Abstract","values":["Chemical detection is of importance in research and industry. Optical sensors based on contact imaging realize the chemical detection in compact, efficient and inexpensive ways. In the first project real-time optical pH sensor based on complementary metal–oxide–semiconductor (CMOS) contact imaging and microfluidics, an optical contact imaging sensor for pH detection with capillary microfluidics is proposed. The CMOS array detects the changes of light intensity after absorption by phenol red doped sol-gel filters while the level of absorbance corresponds to a pH value of the analyte. Deposition methods of sol-gel are optimized and compared. In the second project, real-time optical concentration sensor based on Raman scattering, CMOS contact imaging is presented. This biochemical optical sensor is designed for detecting the concentration of solutions. It is built with a laser diode, an optical filter, a sample holder and a commercial CMOS sensor."]},{"key":"dc:title","label":"Title","values":["Compact Optical Sensing Systems for pH and Other Substances Detection - Theory and Implementation"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:request.copy","label":"Local Request Copy","values":["true"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"atmire:migration.oldid":["4447"],"dc:contributor.advisor":["Yadid-Pecht, Orly"],"dc:contributor.committeemember":["Yadid-Pecht, Orly","Murari, Kartikeya","Chodavarapu, Vamsy"],"dc:creator":["Cao, Muyun"],"dc:date.accessioned":["2016-05-17T20:40:45Z"],"dc:date.available":["2016-05-17T20:40:45Z"],"dc:date.issued":["2016"],"dc:date.submitted":["2016"],"dc:description.abstract":["Chemical detection is of importance in research and industry. Optical sensors based on contact imaging realize the chemical detection in compact, efficient and inexpensive ways. In the first project real-time optical pH sensor based on complementary metal–oxide–semiconductor (CMOS) contact imaging and microfluidics, an optical contact imaging sensor for pH detection with capillary microfluidics is proposed. The CMOS array detects the changes of light intensity after absorption by phenol red doped sol-gel filters while the level of absorbance corresponds to a pH value of the analyte. Deposition methods of sol-gel are optimized and compared. In the second project, real-time optical concentration sensor based on Raman scattering, CMOS contact imaging is presented. This biochemical optical sensor is designed for detecting the concentration of solutions. It is built with a laser diode, an optical filter, a sample holder and a commercial CMOS sensor."],"dc:identifier.citation":["Cao, M. (2016). Compact Optical Sensing Systems for pH and Other Substances Detection - Theory and Implementation (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca. doi:10.11575/PRISM/25367"],"dc:identifier.doi":["http://dx.doi.org/10.11575/PRISM/25367"],"dc:identifier.uri":["http://hdl.handle.net/11023/3020"],"dc:language.iso":["eng"],"dc:publisher.faculty":["Graduate Studies"],"dc:publisher.institution":["University of Calgary"],"dc:publisher.place":["Calgary"],"dc:rights":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."],"dc:subject":["Engineering--Electronics and Electrical"],"dc:subject.classification":["Sensor","optical","Chemical","CMOS","pH"],"dc:title":["Compact Optical Sensing Systems for pH and Other Substances Detection - Theory and Implementation"],"dc:type":["master thesis"],"dspace:entity.type":["Publication"],"local:request.copy":["true"],"others:access_status":["open.access"],"thesis:degree_discipline":["Electrical and Computer Engineering"],"thesis:degree_name":["Master of Science (MSc)"],"thesis:institution_name":["University of Calgary"]},"updated_at":"2026-11-19T07:11:00Z"}