{"id":{"repo_id":"calgary","oai_identifier":"oai:ucalgary.scholaris.ca:11023/3171"},"canonical_url":"https://search.ndltd.org/etd/calgary/oai:ucalgary.scholaris.ca:11023/3171","repository":{"repo_id":"calgary","name":"University of Calgary","base_url":"https://ucalgary.scholaris.ca/server/oai/request"},"display":{"title":"Removal of Emulsified Oil from SAGD Produced Water by Adsorption Coupled with Electrochemical Regeneration","abstract":"Adsorption is an effective method for oil removal as it is a simple process with low processing costs. In order to make the adsorption process cost-effective, not only the adsorbent adsorptive capacity but also regeneration performance should be considered. Graphite intercalation compound (GIC) is a non-porous material with good electrical conductivity. These characteristics make GIC suitable for an innovative adsorption/regeneration process. Adsorption and regeneration processes are done in the same device and GIC is electrochemically regenerated after each adsorption cycle. In this study, the performance of the technology for removing oil from SAGD produced water and synthetic emulsions was studied. Effective and fast oil removal achieving in less than 30 min and full recovery of adsorbent adsorptive capacity was among the promising results. Energy consumption for regeneration of adsorbents was 22.4 and 35.8 kWh per kg of COD to be treated for treatment of synthetic emulsion and produced water, respectively.","abstract_html":"Adsorption is an effective method for oil removal as it is a simple process with low processing costs. In order to make the adsorption process cost-effective, not only the adsorbent adsorptive capacity but also regeneration performance should be considered. Graphite intercalation compound (GIC) is a non-porous material with good electrical conductivity. These characteristics make GIC suitable for an innovative adsorption/regeneration process. Adsorption and regeneration processes are done in the same device and GIC is electrochemically regenerated after each adsorption cycle. In this study, the performance of the technology for removing oil from SAGD produced water and synthetic emulsions was studied. Effective and fast oil removal achieving in less than 30 min and full recovery of adsorbent adsorptive capacity was among the promising results. Energy consumption for regeneration of adsorbents was 22.4 and 35.8 kWh per kg of COD to be treated for treatment of synthetic emulsion and produced water, respectively.","abstract_has_math":false,"creators":["Fallah, Zohreh"],"institution":"Graduate Studies","degree_name":"Master of Science (MSc)","degree_level":null,"degree_discipline":"Chemical and Petroleum Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Roberts, Edward P. L."],"committee_chairs":[],"committee_members":["Tay, Joo-Hwa","Hill, Josephine Mary","Trifkovic, Milana"],"year":2016,"date_issued":"2016","date_published":"2016","updated_at":"2026-11-19T07:25:10Z","subjects":["Engineering","Engineering--Environmental"],"languages":["eng"],"rights":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/11023/3171"],"render_values":[{"text":"http://hdl.handle.net/11023/3171","href":"https://hdl.handle.net/11023/3171","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.11575/PRISM/27626","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.11575/PRISM/27626","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Acalgary%3Aoai%3Aucalgary.scholaris.ca%3A11023%2F3171","prefix":"oai_dc"},"source_record":{"url":"https://ucalgary.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aucalgary.scholaris.ca%3A11023%2F3171","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Roberts, Edward P. L."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Tay, Joo-Hwa","Hill, Josephine Mary","Trifkovic, Milana"]},{"key":"dc:creator","label":"Author","values":["Fallah, Zohreh"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2016-08-08T21:22:03Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2016-08-08T21:22:03Z"]},{"key":"dc:date.issued","label":"Date","values":["2016"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["2016"]},{"key":"dc:publisher.faculty","label":"Dc Publisher Faculty","values":["Graduate Studies"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Calgary"]},{"key":"dc:publisher.place","label":"Dc Publisher Place","values":["Calgary"]},{"key":"dc:type","label":"Dc Type","values":["master thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Chemical and Petroleum Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MSc)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Calgary"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Engineering","Engineering--Environmental"]},{"key":"dc:subject.classification","label":"Dc Subject Classification","values":["Adsorption, Electrochemical regeneration, Emulsion"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Fallah, Z. (2016). Removal of Emulsified Oil from SAGD Produced Water by Adsorption Coupled with Electrochemical Regeneration (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca. doi:10.11575/PRISM/27626"]},{"key":"dc:identifier.doi","label":"DOI","values":["http://dx.doi.org/10.11575/PRISM/27626"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/11023/3171"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"atmire:migration.oldid","label":"Atmire Migration Oldid","values":["4703"]},{"key":"dc:description.abstract","label":"Abstract","values":["Adsorption is an effective method for oil removal as it is a simple process with low processing costs. In order to make the adsorption process cost-effective, not only the adsorbent adsorptive capacity but also regeneration performance should be considered. Graphite intercalation compound (GIC) is a non-porous material with good electrical conductivity. These characteristics make GIC suitable for an innovative adsorption/regeneration process. Adsorption and regeneration processes are done in the same device and GIC is electrochemically regenerated after each adsorption cycle. In this study, the performance of the technology for removing oil from SAGD produced water and synthetic emulsions was studied. Effective and fast oil removal achieving in less than 30 min and full recovery of adsorbent adsorptive capacity was among the promising results. Energy consumption for regeneration of adsorbents was 22.4 and 35.8 kWh per kg of COD to be treated for treatment of synthetic emulsion and produced water, respectively."]},{"key":"dc:title","label":"Title","values":["Removal of Emulsified Oil from SAGD Produced Water by Adsorption Coupled with Electrochemical Regeneration"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:request.copy","label":"Local Request Copy","values":["true"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"atmire:migration.oldid":["4703"],"dc:contributor.advisor":["Roberts, Edward P. L."],"dc:contributor.committeemember":["Tay, Joo-Hwa","Hill, Josephine Mary","Trifkovic, Milana"],"dc:creator":["Fallah, Zohreh"],"dc:date.accessioned":["2016-08-08T21:22:03Z"],"dc:date.available":["2016-08-08T21:22:03Z"],"dc:date.issued":["2016"],"dc:date.submitted":["2016"],"dc:description.abstract":["Adsorption is an effective method for oil removal as it is a simple process with low processing costs. In order to make the adsorption process cost-effective, not only the adsorbent adsorptive capacity but also regeneration performance should be considered. Graphite intercalation compound (GIC) is a non-porous material with good electrical conductivity. These characteristics make GIC suitable for an innovative adsorption/regeneration process. Adsorption and regeneration processes are done in the same device and GIC is electrochemically regenerated after each adsorption cycle. In this study, the performance of the technology for removing oil from SAGD produced water and synthetic emulsions was studied. Effective and fast oil removal achieving in less than 30 min and full recovery of adsorbent adsorptive capacity was among the promising results. Energy consumption for regeneration of adsorbents was 22.4 and 35.8 kWh per kg of COD to be treated for treatment of synthetic emulsion and produced water, respectively."],"dc:identifier.citation":["Fallah, Z. (2016). Removal of Emulsified Oil from SAGD Produced Water by Adsorption Coupled with Electrochemical Regeneration (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca. doi:10.11575/PRISM/27626"],"dc:identifier.doi":["http://dx.doi.org/10.11575/PRISM/27626"],"dc:identifier.uri":["http://hdl.handle.net/11023/3171"],"dc:language.iso":["eng"],"dc:publisher.faculty":["Graduate Studies"],"dc:publisher.institution":["University of Calgary"],"dc:publisher.place":["Calgary"],"dc:rights":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."],"dc:subject":["Engineering","Engineering--Environmental"],"dc:subject.classification":["Adsorption, Electrochemical regeneration, Emulsion"],"dc:title":["Removal of Emulsified Oil from SAGD Produced Water by Adsorption Coupled with Electrochemical Regeneration"],"dc:type":["master thesis"],"dspace:entity.type":["Publication"],"local:request.copy":["true"],"others:access_status":["open.access"],"thesis:degree_discipline":["Chemical and Petroleum Engineering"],"thesis:degree_name":["Master of Science (MSc)"],"thesis:institution_name":["University of Calgary"]},"updated_at":"2026-11-19T07:25:10Z"}