{"id":{"repo_id":"calgary","oai_identifier":"oai:ucalgary.scholaris.ca:11023/3201"},"canonical_url":"https://search.ndltd.org/etd/calgary/oai:ucalgary.scholaris.ca:11023/3201","repository":{"repo_id":"calgary","name":"University of Calgary","base_url":"https://ucalgary.scholaris.ca/server/oai/request"},"display":{"title":"Enhanced Electrogastrography Using Transcutaneous Intraluminal Impedance Measurements (TIIM)","abstract":"Gastric motility and gastric emptying rates have been implicated in the symptoms of functional dyspepsia and gastroparesis. The current gold standard to assess gastric emptying is scintigraphy, which is limited by standardization and radiation concerns. This highlights the need for a novel method of assessing gastric motility. Transcutaneous Intraluminal Impedance Measurement (TIIM) is a novel method of assessing gastric motility. By measuring the dynamics of a known signal emitted from a battery-powered gastric retentive oscillator within the stomach, gastric motility can be quantified. In an eight-dog sham comparison study, TIIM was compared to force transducers implanted on the stomach. Two assessment metrics demonstrated statistically significant Pearson correlation coefficients between active TIIM pills and the force transducers (p<0.01, p<0.05), but not when TIIM pills were replaced by sham deactivated pills (p>0.1, p>0.1). A novel portable TIIM receiver was also proposed and tested in the lab to facilitate future ambulatory studies.","abstract_html":"Gastric motility and gastric emptying rates have been implicated in the symptoms of functional dyspepsia and gastroparesis. The current gold standard to assess gastric emptying is scintigraphy, which is limited by standardization and radiation concerns. This highlights the need for a novel method of assessing gastric motility. Transcutaneous Intraluminal Impedance Measurement (TIIM) is a novel method of assessing gastric motility. By measuring the dynamics of a known signal emitted from a battery-powered gastric retentive oscillator within the stomach, gastric motility can be quantified. In an eight-dog sham comparison study, TIIM was compared to force transducers implanted on the stomach. Two assessment metrics demonstrated statistically significant Pearson correlation coefficients between active TIIM pills and the force transducers (p&lt;0.01, p&lt;0.05), but not when TIIM pills were replaced by sham deactivated pills (p&gt;0.1, p&gt;0.1). A novel portable TIIM receiver was also proposed and tested in the lab to facilitate future ambulatory studies.","abstract_has_math":false,"creators":["Poscente, Michael Dennis"],"institution":"Graduate Studies","degree_name":"Master of Science (MSc)","degree_level":null,"degree_discipline":"Biomedical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Mintchev, Martin","Yadid-Pecht, Orly"],"committee_chairs":[],"committee_members":["Bartley, Norman","Matyas, John","Murari, Kartikeya","Andrews, Christopher"],"year":2016,"date_issued":"2016","date_published":"2016","updated_at":"2026-11-19T07:30:27Z","subjects":["Engineering--Biomedical"],"languages":["eng"],"rights":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/11023/3201"],"render_values":[{"text":"http://hdl.handle.net/11023/3201","href":"https://hdl.handle.net/11023/3201","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.11575/PRISM/25899","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.11575/PRISM/25899","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://ucalgary.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aucalgary.scholaris.ca%3A11023%2F3201","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Mintchev, Martin","Yadid-Pecht, Orly"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Bartley, Norman","Matyas, John","Murari, Kartikeya","Andrews, Christopher"]},{"key":"dc:creator","label":"Author","values":["Poscente, Michael Dennis"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2016-08-22T19:53:21Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2016-08-22T19:53:21Z"]},{"key":"dc:date.issued","label":"Date","values":["2016"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["2016"]},{"key":"dc:publisher.faculty","label":"Dc Publisher Faculty","values":["Graduate Studies"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Calgary"]},{"key":"dc:publisher.place","label":"Dc Publisher Place","values":["Calgary"]},{"key":"dc:type","label":"Dc Type","values":["master thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MSc)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Calgary"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Engineering--Biomedical"]},{"key":"dc:subject.classification","label":"Dc Subject Classification","values":["Transcutaneous Intraluminal Impedance Measurements"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Poscente, M. D. (2016). Enhanced Electrogastrography Using Transcutaneous Intraluminal Impedance Measurements (TIIM) (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca. doi:10.11575/PRISM/25899"]},{"key":"dc:identifier.doi","label":"DOI","values":["http://dx.doi.org/10.11575/PRISM/25899"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/11023/3201"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"atmire:migration.oldid","label":"Atmire Migration Oldid","values":["4784"]},{"key":"dc:description.abstract","label":"Abstract","values":["Gastric motility and gastric emptying rates have been implicated in the symptoms of functional dyspepsia and gastroparesis. The current gold standard to assess gastric emptying is scintigraphy, which is limited by standardization and radiation concerns. This highlights the need for a novel method of assessing gastric motility. Transcutaneous Intraluminal Impedance Measurement (TIIM) is a novel method of assessing gastric motility. By measuring the dynamics of a known signal emitted from a battery-powered gastric retentive oscillator within the stomach, gastric motility can be quantified. In an eight-dog sham comparison study, TIIM was compared to force transducers implanted on the stomach. Two assessment metrics demonstrated statistically significant Pearson correlation coefficients between active TIIM pills and the force transducers (p<0.01, p<0.05), but not when TIIM pills were replaced by sham deactivated pills (p>0.1, p>0.1). A novel portable TIIM receiver was also proposed and tested in the lab to facilitate future ambulatory studies."]},{"key":"dc:title","label":"Title","values":["Enhanced Electrogastrography Using Transcutaneous Intraluminal Impedance Measurements (TIIM)"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:request.copy","label":"Local Request Copy","values":["true"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"atmire:migration.oldid":["4784"],"dc:contributor.advisor":["Mintchev, Martin","Yadid-Pecht, Orly"],"dc:contributor.committeemember":["Bartley, Norman","Matyas, John","Murari, Kartikeya","Andrews, Christopher"],"dc:creator":["Poscente, Michael Dennis"],"dc:date.accessioned":["2016-08-22T19:53:21Z"],"dc:date.available":["2016-08-22T19:53:21Z"],"dc:date.issued":["2016"],"dc:date.submitted":["2016"],"dc:description.abstract":["Gastric motility and gastric emptying rates have been implicated in the symptoms of functional dyspepsia and gastroparesis. The current gold standard to assess gastric emptying is scintigraphy, which is limited by standardization and radiation concerns. This highlights the need for a novel method of assessing gastric motility. Transcutaneous Intraluminal Impedance Measurement (TIIM) is a novel method of assessing gastric motility. By measuring the dynamics of a known signal emitted from a battery-powered gastric retentive oscillator within the stomach, gastric motility can be quantified. In an eight-dog sham comparison study, TIIM was compared to force transducers implanted on the stomach. Two assessment metrics demonstrated statistically significant Pearson correlation coefficients between active TIIM pills and the force transducers (p<0.01, p<0.05), but not when TIIM pills were replaced by sham deactivated pills (p>0.1, p>0.1). A novel portable TIIM receiver was also proposed and tested in the lab to facilitate future ambulatory studies."],"dc:identifier.citation":["Poscente, M. D. (2016). Enhanced Electrogastrography Using Transcutaneous Intraluminal Impedance Measurements (TIIM) (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca. doi:10.11575/PRISM/25899"],"dc:identifier.doi":["http://dx.doi.org/10.11575/PRISM/25899"],"dc:identifier.uri":["http://hdl.handle.net/11023/3201"],"dc:language.iso":["eng"],"dc:publisher.faculty":["Graduate Studies"],"dc:publisher.institution":["University of Calgary"],"dc:publisher.place":["Calgary"],"dc:rights":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."],"dc:subject":["Engineering--Biomedical"],"dc:subject.classification":["Transcutaneous Intraluminal Impedance Measurements"],"dc:title":["Enhanced Electrogastrography Using Transcutaneous Intraluminal Impedance Measurements (TIIM)"],"dc:type":["master thesis"],"dspace:entity.type":["Publication"],"local:request.copy":["true"],"others:access_status":["open.access"],"thesis:degree_discipline":["Biomedical Engineering"],"thesis:degree_name":["Master of Science (MSc)"],"thesis:institution_name":["University of Calgary"]},"updated_at":"2026-11-19T07:30:27Z"}