{"id":{"repo_id":"calgary","oai_identifier":"oai:ucalgary.scholaris.ca:11023/3207"},"canonical_url":"https://search.ndltd.org/etd/calgary/oai:ucalgary.scholaris.ca:11023/3207","repository":{"repo_id":"calgary","name":"University of Calgary","base_url":"https://ucalgary.scholaris.ca/server/oai/request"},"display":{"title":"Far-Field Linear Optical Superresolution via Heterodyne Detection in a Higher-Order Local Oscillator Mode","abstract":"Rayleigh criterion has been the unbreakable rule for direct imaging. In the past few decades, new imaging techniques emerged to circumvent Rayleigh limit by changing the imaging conditions. By analysing the optical field in image plane with quantum optics, one can find quantum Fisher information for estimating the distance between two light sources remains constant, which means one can always estimate this distance with finite error. This discovery makes Rayleigh criterion irrelevant to quantum optimal measurements. Inspired by the theoretical analysis, we propose an experimental implementation to achieve sub-Rayleigh resolution. Using optical heterodyne detection with a local oscillator in TEM01, we can measure the single slit position within 0.0015 and 0.012 of Rayleigh limit for coherent and incoherent light. We can also measure the distance between two slits emitting incoherent light within 0.019 of Rayleigh limit. By engaging more Hermite-Gaussian modes, we can reconstruct the full image.","abstract_html":"Rayleigh criterion has been the unbreakable rule for direct imaging. In the past few decades, new imaging techniques emerged to circumvent Rayleigh limit by changing the imaging conditions. By analysing the optical field in image plane with quantum optics, one can find quantum Fisher information for estimating the distance between two light sources remains constant, which means one can always estimate this distance with finite error. This discovery makes Rayleigh criterion irrelevant to quantum optimal measurements. Inspired by the theoretical analysis, we propose an experimental implementation to achieve sub-Rayleigh resolution. Using optical heterodyne detection with a local oscillator in TEM01, we can measure the single slit position within 0.0015 and 0.012 of Rayleigh limit for coherent and incoherent light. We can also measure the distance between two slits emitting incoherent light within 0.019 of Rayleigh limit. By engaging more Hermite-Gaussian modes, we can reconstruct the full image.","abstract_has_math":false,"creators":["Yang, Fan"],"institution":"Graduate Studies","degree_name":"Master of Science (MSc)","degree_level":null,"degree_discipline":"Physics and Astronomy","degree_department":null,"school":null,"contributors":[],"advisors":["Lvovsky, Alexander"],"committee_chairs":[],"committee_members":["Murari, Kartikeya","Simon, Christoph","Barclay, Paul"],"year":2016,"date_issued":"2016","date_published":"2016","updated_at":"2026-11-19T07:25:10Z","subjects":["Optics"],"languages":["eng"],"rights":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.doi","label":"DOI","values":["http://dx.doi.org/10.11575/PRISM/26162"],"render_values":[{"text":"http://dx.doi.org/10.11575/PRISM/26162","href":"http://dx.doi.org/10.11575/PRISM/26162","code":true}]},{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Yang, F. (2016). Far-Field Linear Optical Superresolution via Heterodyne Detection in a Higher-Order Local Oscillator Mode (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca. doi:10.11575/PRISM/26162"],"render_values":[{"text":"Yang, F. (2016). Far-Field Linear Optical Superresolution via Heterodyne Detection in a Higher-Order Local Oscillator Mode (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca. doi:10.11575/PRISM/26162","href":"https://doi.org/10.11575/PRISM/26162","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/11023/3207","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/11023/3207","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://ucalgary.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aucalgary.scholaris.ca%3A11023%2F3207","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Lvovsky, Alexander"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Murari, Kartikeya","Simon, Christoph","Barclay, Paul"]},{"key":"dc:creator","label":"Author","values":["Yang, Fan"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2016-08-23T15:49:16Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2016-08-23T15:49:16Z"]},{"key":"dc:date.issued","label":"Date","values":["2016"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["2016"]},{"key":"dc:publisher.faculty","label":"Dc Publisher Faculty","values":["Graduate Studies"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Calgary"]},{"key":"dc:publisher.place","label":"Dc Publisher Place","values":["Calgary"]},{"key":"dc:type","label":"Dc Type","values":["master thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Physics and Astronomy"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MSc)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Calgary"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Optics"]},{"key":"dc:subject.classification","label":"Dc Subject Classification","values":["superresolution","heterodyne detection","Imaging"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Yang, F. (2016). Far-Field Linear Optical Superresolution via Heterodyne Detection in a Higher-Order Local Oscillator Mode (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca. doi:10.11575/PRISM/26162"]},{"key":"dc:identifier.doi","label":"DOI","values":["http://dx.doi.org/10.11575/PRISM/26162"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/11023/3207"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"atmire:migration.oldid","label":"Atmire Migration Oldid","values":["4787"]},{"key":"dc:description.abstract","label":"Abstract","values":["Rayleigh criterion has been the unbreakable rule for direct imaging. In the past few decades, new imaging techniques emerged to circumvent Rayleigh limit by changing the imaging conditions. By analysing the optical field in image plane with quantum optics, one can find quantum Fisher information for estimating the distance between two light sources remains constant, which means one can always estimate this distance with finite error. This discovery makes Rayleigh criterion irrelevant to quantum optimal measurements. Inspired by the theoretical analysis, we propose an experimental implementation to achieve sub-Rayleigh resolution. Using optical heterodyne detection with a local oscillator in TEM01, we can measure the single slit position within 0.0015 and 0.012 of Rayleigh limit for coherent and incoherent light. We can also measure the distance between two slits emitting incoherent light within 0.019 of Rayleigh limit. By engaging more Hermite-Gaussian modes, we can reconstruct the full image."]},{"key":"dc:title","label":"Title","values":["Far-Field Linear Optical Superresolution via Heterodyne Detection in a Higher-Order Local Oscillator Mode"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:request.copy","label":"Local Request Copy","values":["true"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"atmire:migration.oldid":["4787"],"dc:contributor.advisor":["Lvovsky, Alexander"],"dc:contributor.committeemember":["Murari, Kartikeya","Simon, Christoph","Barclay, Paul"],"dc:creator":["Yang, Fan"],"dc:date.accessioned":["2016-08-23T15:49:16Z"],"dc:date.available":["2016-08-23T15:49:16Z"],"dc:date.issued":["2016"],"dc:date.submitted":["2016"],"dc:description.abstract":["Rayleigh criterion has been the unbreakable rule for direct imaging. In the past few decades, new imaging techniques emerged to circumvent Rayleigh limit by changing the imaging conditions. By analysing the optical field in image plane with quantum optics, one can find quantum Fisher information for estimating the distance between two light sources remains constant, which means one can always estimate this distance with finite error. This discovery makes Rayleigh criterion irrelevant to quantum optimal measurements. Inspired by the theoretical analysis, we propose an experimental implementation to achieve sub-Rayleigh resolution. Using optical heterodyne detection with a local oscillator in TEM01, we can measure the single slit position within 0.0015 and 0.012 of Rayleigh limit for coherent and incoherent light. We can also measure the distance between two slits emitting incoherent light within 0.019 of Rayleigh limit. By engaging more Hermite-Gaussian modes, we can reconstruct the full image."],"dc:identifier.citation":["Yang, F. (2016). Far-Field Linear Optical Superresolution via Heterodyne Detection in a Higher-Order Local Oscillator Mode (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca. doi:10.11575/PRISM/26162"],"dc:identifier.doi":["http://dx.doi.org/10.11575/PRISM/26162"],"dc:identifier.uri":["http://hdl.handle.net/11023/3207"],"dc:language.iso":["eng"],"dc:publisher.faculty":["Graduate Studies"],"dc:publisher.institution":["University of Calgary"],"dc:publisher.place":["Calgary"],"dc:rights":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."],"dc:subject":["Optics"],"dc:subject.classification":["superresolution","heterodyne detection","Imaging"],"dc:title":["Far-Field Linear Optical Superresolution via Heterodyne Detection in a Higher-Order Local Oscillator Mode"],"dc:type":["master thesis"],"dspace:entity.type":["Publication"],"local:request.copy":["true"],"others:access_status":["open.access"],"thesis:degree_discipline":["Physics and Astronomy"],"thesis:degree_name":["Master of Science (MSc)"],"thesis:institution_name":["University of Calgary"]},"updated_at":"2026-11-19T07:25:10Z"}