{"id":{"repo_id":"calgary","oai_identifier":"oai:ucalgary.scholaris.ca:11023/3249"},"canonical_url":"https://search.ndltd.org/etd/calgary/oai:ucalgary.scholaris.ca:11023/3249","repository":{"repo_id":"calgary","name":"University of Calgary","base_url":"https://ucalgary.scholaris.ca/server/oai/request"},"display":{"title":"Dosimetric Consequences of Rotational Patient Setup Errors in Stereotactic Radiosurgery","abstract":"The level of rotational patient setup error needed to impact stereotactic radiosurgery (SRS) treatments is not well defined. The purpose of this study was to explore potential rotational setup error thresholds for SRS treatments of brain metastases. The groups analyzed in this study consisted of either single isocentric targets or multiple nonisocentric targets. Rotations between 0.5° and 7° were simulated, and the percent of the target volume that received the prescription dose (Vp) was compared between the original plans and rotation simulations to determine what degree of rotations would cause notable Vp loss. The results suggest that a rotational patient setup error threshold of 2° around all axes for treatments of single isocentric targets is conservative. For treatments of multiple nonisocentric targets, especially those that are far from the treatment isocenter, the rotational setup error threshold may need to be as low as or lower than 0.5°.","abstract_html":"The level of rotational patient setup error needed to impact stereotactic radiosurgery (SRS) treatments is not well defined. The purpose of this study was to explore potential rotational setup error thresholds for SRS treatments of brain metastases. The groups analyzed in this study consisted of either single isocentric targets or multiple nonisocentric targets. Rotations between 0.5° and 7° were simulated, and the percent of the target volume that received the prescription dose (Vp) was compared between the original plans and rotation simulations to determine what degree of rotations would cause notable Vp loss. The results suggest that a rotational patient setup error threshold of 2° around all axes for treatments of single isocentric targets is conservative. For treatments of multiple nonisocentric targets, especially those that are far from the treatment isocenter, the rotational setup error threshold may need to be as low as or lower than 0.5°.","abstract_has_math":false,"creators":["Briscoe, Michael"],"institution":"Graduate Studies","degree_name":"Master of Science (MSc)","degree_level":null,"degree_discipline":"Physics and Astronomy","degree_department":null,"school":null,"contributors":[],"advisors":["Ploquin, Nicolas"],"committee_chairs":[],"committee_members":["Voroney, Jon-Paul","Schinkel, Colleen","Spencer, David","Lim, Gerald"],"year":2016,"date_issued":"2016","date_published":"2016","updated_at":"2026-11-19T07:13:36Z","subjects":["Oncology","Radiology","Physics--Radiation"],"languages":["eng"],"rights":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/11023/3249"],"render_values":[{"text":"http://hdl.handle.net/11023/3249","href":"https://hdl.handle.net/11023/3249","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.11575/PRISM/25738","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.11575/PRISM/25738","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://ucalgary.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aucalgary.scholaris.ca%3A11023%2F3249","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Ploquin, Nicolas"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Voroney, Jon-Paul","Schinkel, Colleen","Spencer, David","Lim, Gerald"]},{"key":"dc:creator","label":"Author","values":["Briscoe, Michael"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2016-09-01T15:27:10Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2016-09-01T15:27:10Z"]},{"key":"dc:date.issued","label":"Date","values":["2016"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["2016"]},{"key":"dc:publisher.faculty","label":"Dc Publisher Faculty","values":["Graduate Studies"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Calgary"]},{"key":"dc:publisher.place","label":"Dc Publisher Place","values":["Calgary"]},{"key":"dc:type","label":"Dc Type","values":["master thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Physics and Astronomy"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MSc)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Calgary"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Oncology","Radiology","Physics--Radiation"]},{"key":"dc:subject.classification","label":"Dc Subject Classification","values":["Stereotactic Radiosurgery","Brain Metastases","Rotational Setup Error","Dosimetric Consequences","Rotation Threshold"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Briscoe, M. (2016). Dosimetric Consequences of Rotational Patient Setup Errors in Stereotactic Radiosurgery (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca. doi:10.11575/PRISM/25738"]},{"key":"dc:identifier.doi","label":"DOI","values":["http://dx.doi.org/10.11575/PRISM/25738"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/11023/3249"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"atmire:migration.oldid","label":"Atmire Migration Oldid","values":["4830"]},{"key":"dc:description.abstract","label":"Abstract","values":["The level of rotational patient setup error needed to impact stereotactic radiosurgery (SRS) treatments is not well defined. The purpose of this study was to explore potential rotational setup error thresholds for SRS treatments of brain metastases. The groups analyzed in this study consisted of either single isocentric targets or multiple nonisocentric targets. Rotations between 0.5° and 7° were simulated, and the percent of the target volume that received the prescription dose (Vp) was compared between the original plans and rotation simulations to determine what degree of rotations would cause notable Vp loss. The results suggest that a rotational patient setup error threshold of 2° around all axes for treatments of single isocentric targets is conservative. For treatments of multiple nonisocentric targets, especially those that are far from the treatment isocenter, the rotational setup error threshold may need to be as low as or lower than 0.5°."]},{"key":"dc:title","label":"Title","values":["Dosimetric Consequences of Rotational Patient Setup Errors in Stereotactic Radiosurgery"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:request.copy","label":"Local Request Copy","values":["true"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"atmire:migration.oldid":["4830"],"dc:contributor.advisor":["Ploquin, Nicolas"],"dc:contributor.committeemember":["Voroney, Jon-Paul","Schinkel, Colleen","Spencer, David","Lim, Gerald"],"dc:creator":["Briscoe, Michael"],"dc:date.accessioned":["2016-09-01T15:27:10Z"],"dc:date.available":["2016-09-01T15:27:10Z"],"dc:date.issued":["2016"],"dc:date.submitted":["2016"],"dc:description.abstract":["The level of rotational patient setup error needed to impact stereotactic radiosurgery (SRS) treatments is not well defined. The purpose of this study was to explore potential rotational setup error thresholds for SRS treatments of brain metastases. The groups analyzed in this study consisted of either single isocentric targets or multiple nonisocentric targets. Rotations between 0.5° and 7° were simulated, and the percent of the target volume that received the prescription dose (Vp) was compared between the original plans and rotation simulations to determine what degree of rotations would cause notable Vp loss. The results suggest that a rotational patient setup error threshold of 2° around all axes for treatments of single isocentric targets is conservative. For treatments of multiple nonisocentric targets, especially those that are far from the treatment isocenter, the rotational setup error threshold may need to be as low as or lower than 0.5°."],"dc:identifier.citation":["Briscoe, M. (2016). Dosimetric Consequences of Rotational Patient Setup Errors in Stereotactic Radiosurgery (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca. doi:10.11575/PRISM/25738"],"dc:identifier.doi":["http://dx.doi.org/10.11575/PRISM/25738"],"dc:identifier.uri":["http://hdl.handle.net/11023/3249"],"dc:language.iso":["eng"],"dc:publisher.faculty":["Graduate Studies"],"dc:publisher.institution":["University of Calgary"],"dc:publisher.place":["Calgary"],"dc:rights":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."],"dc:subject":["Oncology","Radiology","Physics--Radiation"],"dc:subject.classification":["Stereotactic Radiosurgery","Brain Metastases","Rotational Setup Error","Dosimetric Consequences","Rotation Threshold"],"dc:title":["Dosimetric Consequences of Rotational Patient Setup Errors in Stereotactic Radiosurgery"],"dc:type":["master thesis"],"dspace:entity.type":["Publication"],"local:request.copy":["true"],"others:access_status":["open.access"],"thesis:degree_discipline":["Physics and Astronomy"],"thesis:degree_name":["Master of Science (MSc)"],"thesis:institution_name":["University of Calgary"]},"updated_at":"2026-11-19T07:13:36Z"}