{"id":{"repo_id":"calgary","oai_identifier":"oai:ucalgary.scholaris.ca:11023/3295"},"canonical_url":"https://search.ndltd.org/etd/calgary/oai:ucalgary.scholaris.ca:11023/3295","repository":{"repo_id":"calgary","name":"University of Calgary","base_url":"https://ucalgary.scholaris.ca/server/oai/request"},"display":{"title":"The Impact of Resistance on Line Loadability when Selecting Transmission Lines for Dynamic Thermal Line Rating","abstract":"With increased focus on renewable generation, new ways to maximize the existing capacity of an electrical grid are being investigated. One method is to increase the transmission line capacity by using dynamic thermal line rating, or DTLR. One problem facing widespread implementation of DTLR is how to select which transmission lines would benefit most from DTLR installation. Traditionally, DTLR is only applied to transmission lines that are thermally rated. This thesis expands this notion by considering the relationship between conductor temperature and resistance to increase the rating of longer lines (over 80 km) that are not thermally limited. This thesis also determines which transmission lines are suitable for DTLR, based on the maximum thermally limited line length, and investigates how this length changes when DTLR is applied. This thesis then combines the two methods for DTLR to demonstrate the capacity increase for all lengths of transmission lines.","abstract_html":"With increased focus on renewable generation, new ways to maximize the existing capacity of an electrical grid are being investigated. One method is to increase the transmission line capacity by using dynamic thermal line rating, or DTLR. One problem facing widespread implementation of DTLR is how to select which transmission lines would benefit most from DTLR installation. Traditionally, DTLR is only applied to transmission lines that are thermally rated. This thesis expands this notion by considering the relationship between conductor temperature and resistance to increase the rating of longer lines (over 80 km) that are not thermally limited. This thesis also determines which transmission lines are suitable for DTLR, based on the maximum thermally limited line length, and investigates how this length changes when DTLR is applied. This thesis then combines the two methods for DTLR to demonstrate the capacity increase for all lengths of transmission lines.","abstract_has_math":false,"creators":["Dawson, Leanne"],"institution":"Graduate Studies","degree_name":"Master of Science (MSc)","degree_level":null,"degree_discipline":"Electrical and Computer Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Knight, Andrew"],"committee_chairs":[],"committee_members":["Zareipour, Hamidreza","Bergerson, Joule"],"year":2016,"date_issued":"2016","date_published":"2016","updated_at":"2026-11-19T07:28:50Z","subjects":["Engineering--Electronics and Electrical"],"languages":["eng"],"rights":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/11023/3295"],"render_values":[{"text":"http://hdl.handle.net/11023/3295","href":"https://hdl.handle.net/11023/3295","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.11575/PRISM/28189","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.11575/PRISM/28189","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Acalgary%3Aoai%3Aucalgary.scholaris.ca%3A11023%2F3295","prefix":"oai_dc"},"source_record":{"url":"https://ucalgary.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aucalgary.scholaris.ca%3A11023%2F3295","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Knight, Andrew"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Zareipour, Hamidreza","Bergerson, Joule"]},{"key":"dc:creator","label":"Author","values":["Dawson, Leanne"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2016-09-13T18:34:22Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2016-09-13T18:34:22Z"]},{"key":"dc:date.issued","label":"Date","values":["2016"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["2016"]},{"key":"dc:publisher.faculty","label":"Dc Publisher Faculty","values":["Graduate Studies"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Calgary"]},{"key":"dc:publisher.place","label":"Dc Publisher Place","values":["Calgary"]},{"key":"dc:type","label":"Dc Type","values":["master thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical and Computer Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MSc)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Calgary"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Engineering--Electronics and Electrical"]},{"key":"dc:subject.classification","label":"Dc Subject Classification","values":["Power Systems","Dynamic Line Rating","Line Loadability"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Dawson, L. (2016). The Impact of Resistance on Line Loadability when Selecting Transmission Lines for Dynamic Thermal Line Rating (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca. doi:10.11575/PRISM/28189"]},{"key":"dc:identifier.doi","label":"DOI","values":["http://dx.doi.org/10.11575/PRISM/28189"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/11023/3295"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"atmire:migration.oldid","label":"Atmire Migration Oldid","values":["4898"]},{"key":"dc:description.abstract","label":"Abstract","values":["With increased focus on renewable generation, new ways to maximize the existing capacity of an electrical grid are being investigated. One method is to increase the transmission line capacity by using dynamic thermal line rating, or DTLR. One problem facing widespread implementation of DTLR is how to select which transmission lines would benefit most from DTLR installation. Traditionally, DTLR is only applied to transmission lines that are thermally rated. This thesis expands this notion by considering the relationship between conductor temperature and resistance to increase the rating of longer lines (over 80 km) that are not thermally limited. This thesis also determines which transmission lines are suitable for DTLR, based on the maximum thermally limited line length, and investigates how this length changes when DTLR is applied. This thesis then combines the two methods for DTLR to demonstrate the capacity increase for all lengths of transmission lines."]},{"key":"dc:title","label":"Title","values":["The Impact of Resistance on Line Loadability when Selecting Transmission Lines for Dynamic Thermal Line Rating"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:request.copy","label":"Local Request Copy","values":["true"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"atmire:migration.oldid":["4898"],"dc:contributor.advisor":["Knight, Andrew"],"dc:contributor.committeemember":["Zareipour, Hamidreza","Bergerson, Joule"],"dc:creator":["Dawson, Leanne"],"dc:date.accessioned":["2016-09-13T18:34:22Z"],"dc:date.available":["2016-09-13T18:34:22Z"],"dc:date.issued":["2016"],"dc:date.submitted":["2016"],"dc:description.abstract":["With increased focus on renewable generation, new ways to maximize the existing capacity of an electrical grid are being investigated. One method is to increase the transmission line capacity by using dynamic thermal line rating, or DTLR. One problem facing widespread implementation of DTLR is how to select which transmission lines would benefit most from DTLR installation. Traditionally, DTLR is only applied to transmission lines that are thermally rated. This thesis expands this notion by considering the relationship between conductor temperature and resistance to increase the rating of longer lines (over 80 km) that are not thermally limited. This thesis also determines which transmission lines are suitable for DTLR, based on the maximum thermally limited line length, and investigates how this length changes when DTLR is applied. This thesis then combines the two methods for DTLR to demonstrate the capacity increase for all lengths of transmission lines."],"dc:identifier.citation":["Dawson, L. (2016). The Impact of Resistance on Line Loadability when Selecting Transmission Lines for Dynamic Thermal Line Rating (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca. doi:10.11575/PRISM/28189"],"dc:identifier.doi":["http://dx.doi.org/10.11575/PRISM/28189"],"dc:identifier.uri":["http://hdl.handle.net/11023/3295"],"dc:language.iso":["eng"],"dc:publisher.faculty":["Graduate Studies"],"dc:publisher.institution":["University of Calgary"],"dc:publisher.place":["Calgary"],"dc:rights":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."],"dc:subject":["Engineering--Electronics and Electrical"],"dc:subject.classification":["Power Systems","Dynamic Line Rating","Line Loadability"],"dc:title":["The Impact of Resistance on Line Loadability when Selecting Transmission Lines for Dynamic Thermal Line Rating"],"dc:type":["master thesis"],"dspace:entity.type":["Publication"],"local:request.copy":["true"],"others:access_status":["open.access"],"thesis:degree_discipline":["Electrical and Computer Engineering"],"thesis:degree_name":["Master of Science (MSc)"],"thesis:institution_name":["University of Calgary"]},"updated_at":"2026-11-19T07:28:50Z"}