{"id":{"repo_id":"calgary","oai_identifier":"oai:ucalgary.scholaris.ca:11023/3394"},"canonical_url":"https://search.ndltd.org/etd/calgary/oai:ucalgary.scholaris.ca:11023/3394","repository":{"repo_id":"calgary","name":"University of Calgary","base_url":"https://ucalgary.scholaris.ca/server/oai/request"},"display":{"title":"Optoelectronic Systems and Applications for In Vivo Fiber Photometry","abstract":"The emergence of fluorescent reporters has enabled neuroscientists to image neurons in action in live mice. Conventional imaging setups, however, cannot interrogate structures below the surface of the brain, and the animal must be restrained. This work advances fiber photometry, a simple method to monitor the average activity of a population of cells, to enable experiments in freely-moving mice and in deep brain structures. By targeting a small-diameter probe to the structure of interest, single fiber optoelectronic systems may be designed that monitor changes in calcium-mediated fluorescence intensity. The systems are optimized for an application in a CRH-Cre transgenic mouse, with the calcium reporter GCaMP6s, for minimal damage to tissue. This thesis covers: (a) optoelectronic system design, characterization, and refinement (b) application and results in awake and freely-moving mice, (c) investigation into potential artifacts and (d) method and results of an improved targeting protocol.","abstract_html":"The emergence of fluorescent reporters has enabled neuroscientists to image neurons in action in live mice. Conventional imaging setups, however, cannot interrogate structures below the surface of the brain, and the animal must be restrained. This work advances fiber photometry, a simple method to monitor the average activity of a population of cells, to enable experiments in freely-moving mice and in deep brain structures. By targeting a small-diameter probe to the structure of interest, single fiber optoelectronic systems may be designed that monitor changes in calcium-mediated fluorescence intensity. The systems are optimized for an application in a CRH-Cre transgenic mouse, with the calcium reporter GCaMP6s, for minimal damage to tissue. This thesis covers: (a) optoelectronic system design, characterization, and refinement (b) application and results in awake and freely-moving mice, (c) investigation into potential artifacts and (d) method and results of an improved targeting protocol.","abstract_has_math":false,"creators":["Ronayne, Kathryn"],"institution":"Graduate Studies","degree_name":"Master of Science (MSc)","degree_level":null,"degree_discipline":"Biomedical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Murari, Kartikeya"],"committee_chairs":[],"committee_members":["Macnab, Chris","Maundy, Brent","Bains, Jaideep","Frayne, Richard"],"year":2016,"date_issued":"2016","date_published":"2016","updated_at":"2026-11-19T07:27:08Z","subjects":["Neuroscience","Engineering--Biomedical","Engineering--Electronics and Electrical"],"languages":["eng"],"rights":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/11023/3394"],"render_values":[{"text":"http://hdl.handle.net/11023/3394","href":"https://hdl.handle.net/11023/3394","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.11575/PRISM/27220","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.11575/PRISM/27220","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Acalgary%3Aoai%3Aucalgary.scholaris.ca%3A11023%2F3394","prefix":"oai_dc"},"source_record":{"url":"https://ucalgary.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aucalgary.scholaris.ca%3A11023%2F3394","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Murari, Kartikeya"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Macnab, Chris","Maundy, Brent","Bains, Jaideep","Frayne, Richard"]},{"key":"dc:creator","label":"Author","values":["Ronayne, Kathryn"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2016-10-04T18:44:51Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2016-10-04T18:44:51Z"]},{"key":"dc:date.issued","label":"Date","values":["2016"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["2016"]},{"key":"dc:publisher.faculty","label":"Dc Publisher Faculty","values":["Graduate Studies"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Calgary"]},{"key":"dc:publisher.place","label":"Dc Publisher Place","values":["Calgary"]},{"key":"dc:type","label":"Dc Type","values":["master thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MSc)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Calgary"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Neuroscience","Engineering--Biomedical","Engineering--Electronics and Electrical"]},{"key":"dc:subject.classification","label":"Dc Subject Classification","values":["optical fibers","Fluorescence","optogenetics","photonics","Spectroscopy"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Ronayne, K. (2016). Optoelectronic Systems and Applications for In Vivo Fiber Photometry (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca. doi:10.11575/PRISM/27220"]},{"key":"dc:identifier.doi","label":"DOI","values":["http://dx.doi.org/10.11575/PRISM/27220"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/11023/3394"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"atmire:migration.oldid","label":"Atmire Migration Oldid","values":["5046"]},{"key":"dc:description.abstract","label":"Abstract","values":["The emergence of fluorescent reporters has enabled neuroscientists to image neurons in action in live mice. Conventional imaging setups, however, cannot interrogate structures below the surface of the brain, and the animal must be restrained. This work advances fiber photometry, a simple method to monitor the average activity of a population of cells, to enable experiments in freely-moving mice and in deep brain structures. By targeting a small-diameter probe to the structure of interest, single fiber optoelectronic systems may be designed that monitor changes in calcium-mediated fluorescence intensity. The systems are optimized for an application in a CRH-Cre transgenic mouse, with the calcium reporter GCaMP6s, for minimal damage to tissue. This thesis covers: (a) optoelectronic system design, characterization, and refinement (b) application and results in awake and freely-moving mice, (c) investigation into potential artifacts and (d) method and results of an improved targeting protocol."]},{"key":"dc:title","label":"Title","values":["Optoelectronic Systems and Applications for In Vivo Fiber Photometry"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:request.copy","label":"Local Request Copy","values":["true"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"atmire:migration.oldid":["5046"],"dc:contributor.advisor":["Murari, Kartikeya"],"dc:contributor.committeemember":["Macnab, Chris","Maundy, Brent","Bains, Jaideep","Frayne, Richard"],"dc:creator":["Ronayne, Kathryn"],"dc:date.accessioned":["2016-10-04T18:44:51Z"],"dc:date.available":["2016-10-04T18:44:51Z"],"dc:date.issued":["2016"],"dc:date.submitted":["2016"],"dc:description.abstract":["The emergence of fluorescent reporters has enabled neuroscientists to image neurons in action in live mice. Conventional imaging setups, however, cannot interrogate structures below the surface of the brain, and the animal must be restrained. This work advances fiber photometry, a simple method to monitor the average activity of a population of cells, to enable experiments in freely-moving mice and in deep brain structures. By targeting a small-diameter probe to the structure of interest, single fiber optoelectronic systems may be designed that monitor changes in calcium-mediated fluorescence intensity. The systems are optimized for an application in a CRH-Cre transgenic mouse, with the calcium reporter GCaMP6s, for minimal damage to tissue. This thesis covers: (a) optoelectronic system design, characterization, and refinement (b) application and results in awake and freely-moving mice, (c) investigation into potential artifacts and (d) method and results of an improved targeting protocol."],"dc:identifier.citation":["Ronayne, K. (2016). Optoelectronic Systems and Applications for In Vivo Fiber Photometry (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca. doi:10.11575/PRISM/27220"],"dc:identifier.doi":["http://dx.doi.org/10.11575/PRISM/27220"],"dc:identifier.uri":["http://hdl.handle.net/11023/3394"],"dc:language.iso":["eng"],"dc:publisher.faculty":["Graduate Studies"],"dc:publisher.institution":["University of Calgary"],"dc:publisher.place":["Calgary"],"dc:rights":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."],"dc:subject":["Neuroscience","Engineering--Biomedical","Engineering--Electronics and Electrical"],"dc:subject.classification":["optical fibers","Fluorescence","optogenetics","photonics","Spectroscopy"],"dc:title":["Optoelectronic Systems and Applications for In Vivo Fiber Photometry"],"dc:type":["master thesis"],"dspace:entity.type":["Publication"],"local:request.copy":["true"],"others:access_status":["open.access"],"thesis:degree_discipline":["Biomedical Engineering"],"thesis:degree_name":["Master of Science (MSc)"],"thesis:institution_name":["University of Calgary"]},"updated_at":"2026-11-19T07:27:08Z"}