{"id":{"repo_id":"calgary","oai_identifier":"oai:ucalgary.scholaris.ca:11023/3985"},"canonical_url":"https://search.ndltd.org/etd/calgary/oai:ucalgary.scholaris.ca:11023/3985","repository":{"repo_id":"calgary","name":"University of Calgary","base_url":"https://ucalgary.scholaris.ca/server/oai/request"},"display":{"title":"Computer-assisted Screening of Motion Artefact for Quality Control in Large-scale MR Imaging Trials","abstract":"As the scale of medical imaging trials increases, manual quality control of the enormous volume of imaging data becomes intractable and costly. Machine learning may provide solutions to reduce the challenge of these large trials through the development of computer-assisted screening tools. The objective of this dissertation was to evaluate the suitability of machine learning for solving scalability problems of manual quality control by training an automated classifier to detect simulated motion artefact on otherwise high-quality magnetic resonance images of healthy human brain. The classifier achieved high accuracy (98.5%) without any performance optimization, and, incidentally, discovered a screening error within the experiment dataset, further demonstrating the power of machine learning in this domain and encouraging further research towards computer-assisted screening tools.","abstract_html":"As the scale of medical imaging trials increases, manual quality control of the enormous volume of imaging data becomes intractable and costly. Machine learning may provide solutions to reduce the challenge of these large trials through the development of computer-assisted screening tools. The objective of this dissertation was to evaluate the suitability of machine learning for solving scalability problems of manual quality control by training an automated classifier to detect simulated motion artefact on otherwise high-quality magnetic resonance images of healthy human brain. The classifier achieved high accuracy (98.5%) without any performance optimization, and, incidentally, discovered a screening error within the experiment dataset, further demonstrating the power of machine learning in this domain and encouraging further research towards computer-assisted screening tools.","abstract_has_math":false,"creators":["Adair, David"],"institution":"Graduate Studies","degree_name":"Master of Science (MSc)","degree_level":null,"degree_discipline":"Biomedical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Frayne, Richard"],"committee_chairs":[],"committee_members":["Gobbi, David","Hu, Yaoping","Krishnamurthy, Diwakar"],"year":2017,"date_issued":"2017","date_published":"2017","updated_at":"2026-11-19T07:32:06Z","subjects":["Radiology","Artificial Intelligence","Computer Science","Engineering--Biomedical","magnetic resonance imaging","Machine Learning","quality control","motion artefact"],"languages":["eng"],"rights":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.doi","label":"DOI","values":["http://dx.doi.org/10.11575/PRISM/25401"],"render_values":[{"text":"http://dx.doi.org/10.11575/PRISM/25401","href":"http://dx.doi.org/10.11575/PRISM/25401","code":true}]},{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Adair, D. (2017). Computer-assisted Screening of Motion Artefact for Quality Control in Large-scale MR Imaging Trials (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca. doi:10.11575/PRISM/25401"],"render_values":[{"text":"Adair, D. (2017). Computer-assisted Screening of Motion Artefact for Quality Control in Large-scale MR Imaging Trials (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca. doi:10.11575/PRISM/25401","href":"https://doi.org/10.11575/PRISM/25401","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/11023/3985","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/11023/3985","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://ucalgary.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aucalgary.scholaris.ca%3A11023%2F3985","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Frayne, Richard"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Gobbi, David","Hu, Yaoping","Krishnamurthy, Diwakar"]},{"key":"dc:creator","label":"Author","values":["Adair, David"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2017-07-25T15:27:13Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2017-07-25T15:27:13Z"]},{"key":"dc:date.issued","label":"Date","values":["2017"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["2017"]},{"key":"dc:publisher.faculty","label":"Dc Publisher Faculty","values":["Graduate Studies"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Calgary"]},{"key":"dc:publisher.place","label":"Dc Publisher Place","values":["Calgary"]},{"key":"dc:type","label":"Dc Type","values":["master thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MSc)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Calgary"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Radiology","Artificial Intelligence","Computer Science","Engineering--Biomedical"]},{"key":"dc:subject.other","label":"Dc Subject Other","values":["magnetic resonance imaging","Machine Learning","radiology","quality control","motion artefact"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Adair, D. (2017). Computer-assisted Screening of Motion Artefact for Quality Control in Large-scale MR Imaging Trials (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca. doi:10.11575/PRISM/25401"]},{"key":"dc:identifier.doi","label":"DOI","values":["http://dx.doi.org/10.11575/PRISM/25401"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/11023/3985"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"atmire:migration.oldid","label":"Atmire Migration Oldid","values":["5809"]},{"key":"dc:description.abstract","label":"Abstract","values":["As the scale of medical imaging trials increases, manual quality control of the enormous volume of imaging data becomes intractable and costly. Machine learning may provide solutions to reduce the challenge of these large trials through the development of computer-assisted screening tools. The objective of this dissertation was to evaluate the suitability of machine learning for solving scalability problems of manual quality control by training an automated classifier to detect simulated motion artefact on otherwise high-quality magnetic resonance images of healthy human brain. The classifier achieved high accuracy (98.5%) without any performance optimization, and, incidentally, discovered a screening error within the experiment dataset, further demonstrating the power of machine learning in this domain and encouraging further research towards computer-assisted screening tools."]},{"key":"dc:title","label":"Title","values":["Computer-assisted Screening of Motion Artefact for Quality Control in Large-scale MR Imaging Trials"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:request.copy","label":"Local Request Copy","values":["true"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"atmire:migration.oldid":["5809"],"dc:contributor.advisor":["Frayne, Richard"],"dc:contributor.committeemember":["Gobbi, David","Hu, Yaoping","Krishnamurthy, Diwakar"],"dc:creator":["Adair, David"],"dc:date.accessioned":["2017-07-25T15:27:13Z"],"dc:date.available":["2017-07-25T15:27:13Z"],"dc:date.issued":["2017"],"dc:date.submitted":["2017"],"dc:description.abstract":["As the scale of medical imaging trials increases, manual quality control of the enormous volume of imaging data becomes intractable and costly. Machine learning may provide solutions to reduce the challenge of these large trials through the development of computer-assisted screening tools. The objective of this dissertation was to evaluate the suitability of machine learning for solving scalability problems of manual quality control by training an automated classifier to detect simulated motion artefact on otherwise high-quality magnetic resonance images of healthy human brain. The classifier achieved high accuracy (98.5%) without any performance optimization, and, incidentally, discovered a screening error within the experiment dataset, further demonstrating the power of machine learning in this domain and encouraging further research towards computer-assisted screening tools."],"dc:identifier.citation":["Adair, D. (2017). Computer-assisted Screening of Motion Artefact for Quality Control in Large-scale MR Imaging Trials (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca. doi:10.11575/PRISM/25401"],"dc:identifier.doi":["http://dx.doi.org/10.11575/PRISM/25401"],"dc:identifier.uri":["http://hdl.handle.net/11023/3985"],"dc:language.iso":["eng"],"dc:publisher.faculty":["Graduate Studies"],"dc:publisher.institution":["University of Calgary"],"dc:publisher.place":["Calgary"],"dc:rights":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."],"dc:subject":["Radiology","Artificial Intelligence","Computer Science","Engineering--Biomedical"],"dc:subject.other":["magnetic resonance imaging","Machine Learning","radiology","quality control","motion artefact"],"dc:title":["Computer-assisted Screening of Motion Artefact for Quality Control in Large-scale MR Imaging Trials"],"dc:type":["master thesis"],"dspace:entity.type":["Publication"],"local:request.copy":["true"],"others:access_status":["open.access"],"thesis:degree_discipline":["Biomedical Engineering"],"thesis:degree_name":["Master of Science (MSc)"],"thesis:institution_name":["University of Calgary"]},"updated_at":"2026-11-19T07:32:06Z"}