{"id":{"repo_id":"calgary","oai_identifier":"oai:ucalgary.scholaris.ca:11023/4096"},"canonical_url":"https://search.ndltd.org/etd/calgary/oai:ucalgary.scholaris.ca:11023/4096","repository":{"repo_id":"calgary","name":"University of Calgary","base_url":"https://ucalgary.scholaris.ca/server/oai/request"},"display":{"title":"An Evaluation of Treatment Planning Strategies to Improve Dose Homogeneity in Permanent Breast Seed Implant","abstract":"There is no evidence in the literature that the seed activity and implantation pattern recommended for permanent breast seed implant (PBSI) are optimal. These planning parameters were systematically evaluated to determine an optimal planning strategy for PBSI. A simple model was used to investigate planning strategies incorporating various Pd-103 seed activities, needle and seed spacings, and implants in which seed positions are either restricted to or permitted outside of spherical target volumes. To address more realistic geometries, model parameters were used to re-plan a 5-patient cohort in MIM Symphony. The results confirm that the current clinical needle-to-needle and seed-to-seed spacing provides the most favourable dose distributions, given the limitations imposed by the implant apparatus. However, a drastic improvement in dose homogeneity, with equivalent coverage and conformity, can be achieved by implanting seeds beyond the PTV within a 0.3 – 0.5 cm margin, and optimizing seed activity on a per patient basis.","abstract_html":"There is no evidence in the literature that the seed activity and implantation pattern recommended for permanent breast seed implant (PBSI) are optimal. These planning parameters were systematically evaluated to determine an optimal planning strategy for PBSI. A simple model was used to investigate planning strategies incorporating various Pd-103 seed activities, needle and seed spacings, and implants in which seed positions are either restricted to or permitted outside of spherical target volumes. To address more realistic geometries, model parameters were used to re-plan a 5-patient cohort in MIM Symphony. The results confirm that the current clinical needle-to-needle and seed-to-seed spacing provides the most favourable dose distributions, given the limitations imposed by the implant apparatus. However, a drastic improvement in dose homogeneity, with equivalent coverage and conformity, can be achieved by implanting seeds beyond the PTV within a 0.3 – 0.5 cm margin, and optimizing seed activity on a per patient basis.","abstract_has_math":false,"creators":["Frederick, Amy"],"institution":"Graduate Studies","degree_name":"Master of Science (MSc)","degree_level":null,"degree_discipline":"Physics and Astronomy","degree_department":null,"school":null,"contributors":[],"advisors":["Roumeliotis, Michael","Villarreal-Barajas, Jose Eduardo"],"committee_chairs":[],"committee_members":["Banerjee, Robyn","Meyer, Tyler","Spencer, David"],"year":2017,"date_issued":"2017","date_published":"2017","updated_at":"2026-11-19T07:25:59Z","subjects":["Physics--Radiation","Permanent Breast Seed Implant","Breast Brachytherapy","Dosimetry","Pd-103","Forward Planning","Treatment Planning","Dose Homogeneity"],"languages":["eng"],"rights":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/11023/4096"],"render_values":[{"text":"http://hdl.handle.net/11023/4096","href":"https://hdl.handle.net/11023/4096","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.11575/PRISM/24862","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.11575/PRISM/24862","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Acalgary%3Aoai%3Aucalgary.scholaris.ca%3A11023%2F4096","prefix":"oai_dc"},"source_record":{"url":"https://ucalgary.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aucalgary.scholaris.ca%3A11023%2F4096","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Roumeliotis, Michael","Villarreal-Barajas, Jose Eduardo"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Banerjee, Robyn","Meyer, Tyler","Spencer, David"]},{"key":"dc:creator","label":"Author","values":["Frederick, Amy"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2017-09-12T19:24:12Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2017-09-12T19:24:12Z"]},{"key":"dc:date.issued","label":"Date","values":["2017"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["2017"]},{"key":"dc:publisher.faculty","label":"Dc Publisher Faculty","values":["Graduate Studies"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Calgary"]},{"key":"dc:publisher.place","label":"Dc Publisher Place","values":["Calgary"]},{"key":"dc:type","label":"Dc Type","values":["master thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Physics and Astronomy"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MSc)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Calgary"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Physics--Radiation"]},{"key":"dc:subject.other","label":"Dc Subject Other","values":["Permanent Breast Seed Implant","Breast Brachytherapy","Dosimetry","Pd-103","Forward Planning","Treatment Planning","Dose Homogeneity"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Frederick, A. (2017). An Evaluation of Treatment Planning Strategies to Improve Dose Homogeneity in Permanent Breast Seed Implant (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca. doi:10.11575/PRISM/24862"]},{"key":"dc:identifier.doi","label":"DOI","values":["http://dx.doi.org/10.11575/PRISM/24862"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/11023/4096"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"atmire:migration.oldid","label":"Atmire Migration Oldid","values":["5966"]},{"key":"dc:description.abstract","label":"Abstract","values":["There is no evidence in the literature that the seed activity and implantation pattern recommended for permanent breast seed implant (PBSI) are optimal. These planning parameters were systematically evaluated to determine an optimal planning strategy for PBSI. A simple model was used to investigate planning strategies incorporating various Pd-103 seed activities, needle and seed spacings, and implants in which seed positions are either restricted to or permitted outside of spherical target volumes. To address more realistic geometries, model parameters were used to re-plan a 5-patient cohort in MIM Symphony. The results confirm that the current clinical needle-to-needle and seed-to-seed spacing provides the most favourable dose distributions, given the limitations imposed by the implant apparatus. However, a drastic improvement in dose homogeneity, with equivalent coverage and conformity, can be achieved by implanting seeds beyond the PTV within a 0.3 – 0.5 cm margin, and optimizing seed activity on a per patient basis."]},{"key":"dc:title","label":"Title","values":["An Evaluation of Treatment Planning Strategies to Improve Dose Homogeneity in Permanent Breast Seed Implant"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:request.copy","label":"Local Request Copy","values":["true"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"atmire:migration.oldid":["5966"],"dc:contributor.advisor":["Roumeliotis, Michael","Villarreal-Barajas, Jose Eduardo"],"dc:contributor.committeemember":["Banerjee, Robyn","Meyer, Tyler","Spencer, David"],"dc:creator":["Frederick, Amy"],"dc:date.accessioned":["2017-09-12T19:24:12Z"],"dc:date.available":["2017-09-12T19:24:12Z"],"dc:date.issued":["2017"],"dc:date.submitted":["2017"],"dc:description.abstract":["There is no evidence in the literature that the seed activity and implantation pattern recommended for permanent breast seed implant (PBSI) are optimal. These planning parameters were systematically evaluated to determine an optimal planning strategy for PBSI. A simple model was used to investigate planning strategies incorporating various Pd-103 seed activities, needle and seed spacings, and implants in which seed positions are either restricted to or permitted outside of spherical target volumes. To address more realistic geometries, model parameters were used to re-plan a 5-patient cohort in MIM Symphony. The results confirm that the current clinical needle-to-needle and seed-to-seed spacing provides the most favourable dose distributions, given the limitations imposed by the implant apparatus. However, a drastic improvement in dose homogeneity, with equivalent coverage and conformity, can be achieved by implanting seeds beyond the PTV within a 0.3 – 0.5 cm margin, and optimizing seed activity on a per patient basis."],"dc:identifier.citation":["Frederick, A. (2017). An Evaluation of Treatment Planning Strategies to Improve Dose Homogeneity in Permanent Breast Seed Implant (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca. doi:10.11575/PRISM/24862"],"dc:identifier.doi":["http://dx.doi.org/10.11575/PRISM/24862"],"dc:identifier.uri":["http://hdl.handle.net/11023/4096"],"dc:language.iso":["eng"],"dc:publisher.faculty":["Graduate Studies"],"dc:publisher.institution":["University of Calgary"],"dc:publisher.place":["Calgary"],"dc:rights":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."],"dc:subject":["Physics--Radiation"],"dc:subject.other":["Permanent Breast Seed Implant","Breast Brachytherapy","Dosimetry","Pd-103","Forward Planning","Treatment Planning","Dose Homogeneity"],"dc:title":["An Evaluation of Treatment Planning Strategies to Improve Dose Homogeneity in Permanent Breast Seed Implant"],"dc:type":["master thesis"],"dspace:entity.type":["Publication"],"local:request.copy":["true"],"others:access_status":["open.access"],"thesis:degree_discipline":["Physics and Astronomy"],"thesis:degree_name":["Master of Science (MSc)"],"thesis:institution_name":["University of Calgary"]},"updated_at":"2026-11-19T07:25:59Z"}