{"id":{"repo_id":"calgary","oai_identifier":"oai:ucalgary.scholaris.ca:11023/4199"},"canonical_url":"https://search.ndltd.org/etd/calgary/oai:ucalgary.scholaris.ca:11023/4199","repository":{"repo_id":"calgary","name":"University of Calgary","base_url":"https://ucalgary.scholaris.ca/server/oai/request"},"display":{"title":"Electromechanical Shape Memory Alloy Actuators for Blood Extraction","abstract":"This thesis concerns the design, prototyping and testing of a series of compact electromechanical actuators for drawing capillary blood for analysis by the e-Mosquito wearable, autonomous glucose monitoring system for diabetes. All the designs used contracting shape memory alloy wires, fixed geometry and millimetre-scale moving parts, primarily to extend a disposable lancet needle from the device and into the skin. The lancet was to enter the skin at an acute angle that increased to 90° at full extension, with the goal of increasing blood flow. Attention was paid to isolation and replaceability of external parts, improving manufacturability and increasing actuator power. Satisfactory control and extension of the lancet along the intended path were achieved, leading to the conclusion that the increased elastic response of skin makes angled needle insertion impractical and to the investigation of other techniques for blood sampling with autonomous devices.","abstract_html":"This thesis concerns the design, prototyping and testing of a series of compact electromechanical actuators for drawing capillary blood for analysis by the e-Mosquito wearable, autonomous glucose monitoring system for diabetes. All the designs used contracting shape memory alloy wires, fixed geometry and millimetre-scale moving parts, primarily to extend a disposable lancet needle from the device and into the skin. The lancet was to enter the skin at an acute angle that increased to 90° at full extension, with the goal of increasing blood flow. Attention was paid to isolation and replaceability of external parts, improving manufacturability and increasing actuator power. Satisfactory control and extension of the lancet along the intended path were achieved, leading to the conclusion that the increased elastic response of skin makes angled needle insertion impractical and to the investigation of other techniques for blood sampling with autonomous devices.","abstract_has_math":false,"creators":["Berka, Martin"],"institution":"Graduate Studies","degree_name":"Master of Science (MSc)","degree_level":null,"degree_discipline":"Electrical and Computer Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Mintchev, Martin","Yadid-Pecht, Orly"],"committee_chairs":[],"committee_members":["Maundy, Brent","Dalton, Colin"],"year":2017,"date_issued":"2017","date_published":"2017","updated_at":"2026-11-19T07:36:41Z","subjects":["Medicine and Surgery","Public Health","Engineering--Biomedical","Engineering--Electronics and Electrical","Engineering--Mechanical","electromechanical actuators","blood sampling","diabetes","nitinol","skin lancing","needles","glucose monitoring","Shape Memory Alloy","wearable","rapid prototyping","design"],"languages":["eng"],"rights":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/11023/4199"],"render_values":[{"text":"http://hdl.handle.net/11023/4199","href":"https://hdl.handle.net/11023/4199","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.11575/PRISM/25862","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.11575/PRISM/25862","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Acalgary%3Aoai%3Aucalgary.scholaris.ca%3A11023%2F4199","prefix":"oai_dc"},"source_record":{"url":"https://ucalgary.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aucalgary.scholaris.ca%3A11023%2F4199","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Mintchev, Martin","Yadid-Pecht, Orly"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Maundy, Brent","Dalton, Colin"]},{"key":"dc:creator","label":"Author","values":["Berka, Martin"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2017-10-03T18:21:13Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2017-10-03T18:21:13Z"]},{"key":"dc:date.issued","label":"Date","values":["2017"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["2017"]},{"key":"dc:publisher.faculty","label":"Dc Publisher Faculty","values":["Graduate Studies"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Calgary"]},{"key":"dc:publisher.place","label":"Dc Publisher Place","values":["Calgary"]},{"key":"dc:type","label":"Dc Type","values":["master thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical and Computer Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MSc)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Calgary"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Medicine and Surgery","Public Health","Engineering--Biomedical","Engineering--Electronics and Electrical","Engineering--Mechanical"]},{"key":"dc:subject.other","label":"Dc Subject Other","values":["electromechanical actuators","blood sampling","diabetes","nitinol","skin lancing","needles","glucose monitoring","Shape Memory Alloy","wearable","rapid prototyping","design"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Berka, M. (2017). Electromechanical Shape Memory Alloy Actuators for Blood Extraction (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca. doi:10.11575/PRISM/25862"]},{"key":"dc:identifier.doi","label":"DOI","values":["http://dx.doi.org/10.11575/PRISM/25862"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/11023/4199"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"atmire:migration.oldid","label":"Atmire Migration Oldid","values":["6117"]},{"key":"dc:description.abstract","label":"Abstract","values":["This thesis concerns the design, prototyping and testing of a series of compact electromechanical actuators for drawing capillary blood for analysis by the e-Mosquito wearable, autonomous glucose monitoring system for diabetes. All the designs used contracting shape memory alloy wires, fixed geometry and millimetre-scale moving parts, primarily to extend a disposable lancet needle from the device and into the skin. The lancet was to enter the skin at an acute angle that increased to 90° at full extension, with the goal of increasing blood flow. Attention was paid to isolation and replaceability of external parts, improving manufacturability and increasing actuator power. Satisfactory control and extension of the lancet along the intended path were achieved, leading to the conclusion that the increased elastic response of skin makes angled needle insertion impractical and to the investigation of other techniques for blood sampling with autonomous devices."]},{"key":"dc:title","label":"Title","values":["Electromechanical Shape Memory Alloy Actuators for Blood Extraction"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:request.copy","label":"Local Request Copy","values":["true"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"atmire:migration.oldid":["6117"],"dc:contributor.advisor":["Mintchev, Martin","Yadid-Pecht, Orly"],"dc:contributor.committeemember":["Maundy, Brent","Dalton, Colin"],"dc:creator":["Berka, Martin"],"dc:date.accessioned":["2017-10-03T18:21:13Z"],"dc:date.available":["2017-10-03T18:21:13Z"],"dc:date.issued":["2017"],"dc:date.submitted":["2017"],"dc:description.abstract":["This thesis concerns the design, prototyping and testing of a series of compact electromechanical actuators for drawing capillary blood for analysis by the e-Mosquito wearable, autonomous glucose monitoring system for diabetes. All the designs used contracting shape memory alloy wires, fixed geometry and millimetre-scale moving parts, primarily to extend a disposable lancet needle from the device and into the skin. The lancet was to enter the skin at an acute angle that increased to 90° at full extension, with the goal of increasing blood flow. Attention was paid to isolation and replaceability of external parts, improving manufacturability and increasing actuator power. Satisfactory control and extension of the lancet along the intended path were achieved, leading to the conclusion that the increased elastic response of skin makes angled needle insertion impractical and to the investigation of other techniques for blood sampling with autonomous devices."],"dc:identifier.citation":["Berka, M. (2017). Electromechanical Shape Memory Alloy Actuators for Blood Extraction (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca. doi:10.11575/PRISM/25862"],"dc:identifier.doi":["http://dx.doi.org/10.11575/PRISM/25862"],"dc:identifier.uri":["http://hdl.handle.net/11023/4199"],"dc:language.iso":["eng"],"dc:publisher.faculty":["Graduate Studies"],"dc:publisher.institution":["University of Calgary"],"dc:publisher.place":["Calgary"],"dc:rights":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."],"dc:subject":["Medicine and Surgery","Public Health","Engineering--Biomedical","Engineering--Electronics and Electrical","Engineering--Mechanical"],"dc:subject.other":["electromechanical actuators","blood sampling","diabetes","nitinol","skin lancing","needles","glucose monitoring","Shape Memory Alloy","wearable","rapid prototyping","design"],"dc:title":["Electromechanical Shape Memory Alloy Actuators for Blood Extraction"],"dc:type":["master thesis"],"dspace:entity.type":["Publication"],"local:request.copy":["true"],"others:access_status":["open.access"],"thesis:degree_discipline":["Electrical and Computer Engineering"],"thesis:degree_name":["Master of Science (MSc)"],"thesis:institution_name":["University of Calgary"]},"updated_at":"2026-11-19T07:36:41Z"}