{"id":{"repo_id":"calgary","oai_identifier":"oai:ucalgary.scholaris.ca:11023/495"},"canonical_url":"https://search.ndltd.org/etd/calgary/oai:ucalgary.scholaris.ca:11023/495","repository":{"repo_id":"calgary","name":"University of Calgary","base_url":"https://ucalgary.scholaris.ca/server/oai/request"},"display":{"title":"Self–stabilizing Capsule Endoscope for Early Detection and Biopsy of Colonic Polyps","abstract":"Capsule endoscopy is a noninvasive method for examining the gastrointestinal (GI) tract and has been very successful in small intestine studies. Recent attempts have been made to utilize this procedure in effective colon screening. However, in the wider colonic lumen the small capsule tumbles, resulting in missed regions and the transmission of images with little clinical utility. In addition, the capsule does not have the capability to insufflate the lumen to provide a more complete visualization of collapsed colonic segments. These limitations in the current application of capsule endoscopy outline the need for a novel method that allows for effective capsule–based imaging of the colon. A self–stabilizing capsule endoscope (SCE) is a unique method that eliminates capsule tumbling in the colon, hence allowing systematic visualization. In this research, a prototype of an SCE enclosed in a colon targeting shell was proposed and tested. The SCE design consists of an inner capsule endoscope (CE) that has an expandable component attached to its trailing end. Upon arrival at the colon, the outer shell dissolves, activating the inner capsule and the expandable component which then grows to stabilize the implement. The SCE travels through the colon by peristalsis, capturing intraluminal images and transmitting them in real time to an external receiver, and is then excreted from the body. As a safety measure, the expandable component can be remotely separated from the capsule. Feasibility of the SCE has been demonstrated in laboratory and acute canine experiments. The self–stabilization technology vastly improves the image quality over commercial, non–stabilized CEs in the colon. In addition, SCE delivers a significant improvement in detection rates of simulated colonic lesions when compared to standard CEs. The SCE is an important contribution to the development of a reliable colon CE. Additionally, a novel biopsy module for the CE was proposed and tested. This module collects samples of tissue and luminal juices anywhere along the GI tract. It is a remotely operated device capable of taking a sample from any point around the 360˚ circumference of the capsule. The functionality and feasibility of the biopsy module for CE was verified in a silicon stomach model.","abstract_html":"Capsule endoscopy is a noninvasive method for examining the gastrointestinal (GI) tract and has been very successful in small intestine studies. Recent attempts have been made to utilize this procedure in effective colon screening. However, in the wider colonic lumen the small capsule tumbles, resulting in missed regions and the transmission of images with little clinical utility. In addition, the capsule does not have the capability to insufflate the lumen to provide a more complete visualization of collapsed colonic segments. These limitations in the current application of capsule endoscopy outline the need for a novel method that allows for effective capsule–based imaging of the colon. A self–stabilizing capsule endoscope (SCE) is a unique method that eliminates capsule tumbling in the colon, hence allowing systematic visualization. In this research, a prototype of an SCE enclosed in a colon targeting shell was proposed and tested. The SCE design consists of an inner capsule endoscope (CE) that has an expandable component attached to its trailing end. Upon arrival at the colon, the outer shell dissolves, activating the inner capsule and the expandable component which then grows to stabilize the implement. The SCE travels through the colon by peristalsis, capturing intraluminal images and transmitting them in real time to an external receiver, and is then excreted from the body. As a safety measure, the expandable component can be remotely separated from the capsule. Feasibility of the SCE has been demonstrated in laboratory and acute canine experiments. The self–stabilization technology vastly improves the image quality over commercial, non–stabilized CEs in the colon. In addition, SCE delivers a significant improvement in detection rates of simulated colonic lesions when compared to standard CEs. The SCE is an important contribution to the development of a reliable colon CE. Additionally, a novel biopsy module for the CE was proposed and tested. This module collects samples of tissue and luminal juices anywhere along the GI tract. It is a remotely operated device capable of taking a sample from any point around the 360˚ circumference of the capsule. The functionality and feasibility of the biopsy module for CE was verified in a silicon stomach model.","abstract_has_math":false,"creators":["Filip, Dobromir"],"institution":"Graduate Studies","degree_name":"Doctor of Philosophy (PhD)","degree_level":null,"degree_discipline":"Electrical and Computer Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Mintchev, Martin","Yadid-Pecht, Orly"],"committee_chairs":[],"committee_members":[],"year":2013,"date_issued":"2013-01-25","date_published":"2013-01-25","updated_at":"2026-11-19T07:37:01Z","subjects":["Engineering--Biomedical"],"languages":["eng"],"rights":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.doi","label":"DOI","values":["http://dx.doi.org/10.11575/PRISM/27746"],"render_values":[{"text":"http://dx.doi.org/10.11575/PRISM/27746","href":"http://dx.doi.org/10.11575/PRISM/27746","code":true}]},{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Filip, D. (2013). Self–stabilizing Capsule Endoscope for Early Detection and Biopsy of Colonic Polyps (Doctoral thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca. doi:10.11575/PRISM/27746"],"render_values":[{"text":"Filip, D. (2013). Self–stabilizing Capsule Endoscope for Early Detection and Biopsy of Colonic Polyps (Doctoral thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca. doi:10.11575/PRISM/27746","href":"https://doi.org/10.11575/PRISM/27746","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/11023/495","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/11023/495","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://ucalgary.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aucalgary.scholaris.ca%3A11023%2F495","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Mintchev, Martin","Yadid-Pecht, Orly"]},{"key":"dc:creator","label":"Author","values":["Filip, Dobromir"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2013-01-25T22:17:48Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2013-06-15T07:01:45Z"]},{"key":"dc:date.issued","label":"Date","values":["2013-01-25"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["2013"]},{"key":"dc:publisher.faculty","label":"Dc Publisher Faculty","values":["Graduate Studies"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Calgary"]},{"key":"dc:publisher.place","label":"Dc Publisher Place","values":["Calgary"]},{"key":"dc:type","label":"Dc Type","values":["doctoral thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical and Computer Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy (PhD)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Calgary"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Engineering--Biomedical"]},{"key":"dc:subject.classification","label":"Dc Subject Classification","values":["Colon capsule endoscopy"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Filip, D. (2013). Self–stabilizing Capsule Endoscope for Early Detection and Biopsy of Colonic Polyps (Doctoral thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca. doi:10.11575/PRISM/27746"]},{"key":"dc:identifier.doi","label":"DOI","values":["http://dx.doi.org/10.11575/PRISM/27746"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/11023/495"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"atmire:migration.oldid","label":"Atmire Migration Oldid","values":["683"]},{"key":"dc:description.abstract","label":"Abstract","values":["Capsule endoscopy is a noninvasive method for examining the gastrointestinal (GI) tract and has been very successful in small intestine studies. Recent attempts have been made to utilize this procedure in effective colon screening. However, in the wider colonic lumen the small capsule tumbles, resulting in missed regions and the transmission of images with little clinical utility. In addition, the capsule does not have the capability to insufflate the lumen to provide a more complete visualization of collapsed colonic segments. These limitations in the current application of capsule endoscopy outline the need for a novel method that allows for effective capsule–based imaging of the colon. A self–stabilizing capsule endoscope (SCE) is a unique method that eliminates capsule tumbling in the colon, hence allowing systematic visualization. In this research, a prototype of an SCE enclosed in a colon targeting shell was proposed and tested. The SCE design consists of an inner capsule endoscope (CE) that has an expandable component attached to its trailing end. Upon arrival at the colon, the outer shell dissolves, activating the inner capsule and the expandable component which then grows to stabilize the implement. The SCE travels through the colon by peristalsis, capturing intraluminal images and transmitting them in real time to an external receiver, and is then excreted from the body. As a safety measure, the expandable component can be remotely separated from the capsule. Feasibility of the SCE has been demonstrated in laboratory and acute canine experiments. The self–stabilization technology vastly improves the image quality over commercial, non–stabilized CEs in the colon. In addition, SCE delivers a significant improvement in detection rates of simulated colonic lesions when compared to standard CEs. The SCE is an important contribution to the development of a reliable colon CE. Additionally, a novel biopsy module for the CE was proposed and tested. This module collects samples of tissue and luminal juices anywhere along the GI tract. It is a remotely operated device capable of taking a sample from any point around the 360˚ circumference of the capsule. The functionality and feasibility of the biopsy module for CE was verified in a silicon stomach model."]},{"key":"dc:title","label":"Title","values":["Self–stabilizing Capsule Endoscope for Early Detection and Biopsy of Colonic Polyps"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:request.copy","label":"Local Request Copy","values":["true"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"atmire:migration.oldid":["683"],"dc:contributor.advisor":["Mintchev, Martin","Yadid-Pecht, Orly"],"dc:creator":["Filip, Dobromir"],"dc:date.accessioned":["2013-01-25T22:17:48Z"],"dc:date.available":["2013-06-15T07:01:45Z"],"dc:date.issued":["2013-01-25"],"dc:date.submitted":["2013"],"dc:description.abstract":["Capsule endoscopy is a noninvasive method for examining the gastrointestinal (GI) tract and has been very successful in small intestine studies. Recent attempts have been made to utilize this procedure in effective colon screening. However, in the wider colonic lumen the small capsule tumbles, resulting in missed regions and the transmission of images with little clinical utility. In addition, the capsule does not have the capability to insufflate the lumen to provide a more complete visualization of collapsed colonic segments. These limitations in the current application of capsule endoscopy outline the need for a novel method that allows for effective capsule–based imaging of the colon. A self–stabilizing capsule endoscope (SCE) is a unique method that eliminates capsule tumbling in the colon, hence allowing systematic visualization. In this research, a prototype of an SCE enclosed in a colon targeting shell was proposed and tested. The SCE design consists of an inner capsule endoscope (CE) that has an expandable component attached to its trailing end. Upon arrival at the colon, the outer shell dissolves, activating the inner capsule and the expandable component which then grows to stabilize the implement. The SCE travels through the colon by peristalsis, capturing intraluminal images and transmitting them in real time to an external receiver, and is then excreted from the body. As a safety measure, the expandable component can be remotely separated from the capsule. Feasibility of the SCE has been demonstrated in laboratory and acute canine experiments. The self–stabilization technology vastly improves the image quality over commercial, non–stabilized CEs in the colon. In addition, SCE delivers a significant improvement in detection rates of simulated colonic lesions when compared to standard CEs. The SCE is an important contribution to the development of a reliable colon CE. Additionally, a novel biopsy module for the CE was proposed and tested. This module collects samples of tissue and luminal juices anywhere along the GI tract. It is a remotely operated device capable of taking a sample from any point around the 360˚ circumference of the capsule. The functionality and feasibility of the biopsy module for CE was verified in a silicon stomach model."],"dc:identifier.citation":["Filip, D. (2013). Self–stabilizing Capsule Endoscope for Early Detection and Biopsy of Colonic Polyps (Doctoral thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca. doi:10.11575/PRISM/27746"],"dc:identifier.doi":["http://dx.doi.org/10.11575/PRISM/27746"],"dc:identifier.uri":["http://hdl.handle.net/11023/495"],"dc:language.iso":["eng"],"dc:publisher.faculty":["Graduate Studies"],"dc:publisher.institution":["University of Calgary"],"dc:publisher.place":["Calgary"],"dc:rights":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."],"dc:subject":["Engineering--Biomedical"],"dc:subject.classification":["Colon capsule endoscopy"],"dc:title":["Self–stabilizing Capsule Endoscope for Early Detection and Biopsy of Colonic Polyps"],"dc:type":["doctoral thesis"],"dspace:entity.type":["Publication"],"local:request.copy":["true"],"others:access_status":["open.access"],"thesis:degree_discipline":["Electrical and Computer Engineering"],"thesis:degree_name":["Doctor of Philosophy (PhD)"],"thesis:institution_name":["University of Calgary"]},"updated_at":"2026-11-19T07:37:01Z"}