{"id":{"repo_id":"calgary","oai_identifier":"oai:ucalgary.scholaris.ca:11023/537"},"canonical_url":"https://search.ndltd.org/etd/calgary/oai:ucalgary.scholaris.ca:11023/537","repository":{"repo_id":"calgary","name":"University of Calgary","base_url":"https://ucalgary.scholaris.ca/server/oai/request"},"display":{"title":"Ultraviolet Degradation of BTX in Waste Gas: Effects of Photocatalysis and Ozone Premixing","abstract":"The focus of this study is on potential modifications of ultraviolet degradation of BTX (Benzene, Toluene and Xylene) in waste gas. A considerable amount of such pollutants is emitted from glycol dehydrators in the natural gas sector. ThePhotolytic technique has been recognized as a promising technique to control BTX emissions to theenvironment. In this work the effectiveness of other alternatives such as photocatalytic technology and photolysis in the presence of ozone are studied. A simulation model developed for benzene photolysis in waste gas by Mahmoudkhani (2012) was extended to include photocatalysis on the reactor wall. The model was applied to a cylindrical reactor containing a 40 W amalgam UV lamp in the axis. The model predictions of photodegradation with 254 nm and 185 nm light irradiation was compared with a combination of photolytic and photocatalytic degradation. At air flow rates of 1 L/min and benzene mass flow rates ranging from 0.5 to 10 mg/min, a degradation efficiency of 77%-23% is predicted for the catalytic process. In comparison, the model of Mahmoudkhani (2012) predicted an efficiency of 95%-20% for the noncatalytic process. However, a maximum quantum yield (ϕ) of 6.67×〖10〗^(-4) was predicted for the photocatalytic process. This low value explains the lack of benefit predicted when a photocatalytic coating is applied. It is concluded that the photolytic approach is a feasible alternative to the photocatalytic approach, especially for low concentrations of benzene emissions from waste gas. Furthermore, adding ozone greatly improves the efficiency of the process. Modeling of photolytic degradation with ozone confirms the experimental results; however, the modeling slightly overestimates the efficiency. Based on energy requirement calculations, it is concluded that the lowest energy is consumed when combination of ozone premixing and condensation pretreatment along with UV photolysis is used.","abstract_html":"The focus of this study is on potential modifications of ultraviolet degradation of BTX (Benzene, Toluene and Xylene) in waste gas. A considerable amount of such pollutants is emitted from glycol dehydrators in the natural gas sector. ThePhotolytic technique has been recognized as a promising technique to control BTX emissions to theenvironment. In this work the effectiveness of other alternatives such as photocatalytic technology and photolysis in the presence of ozone are studied. A simulation model developed for benzene photolysis in waste gas by Mahmoudkhani (2012) was extended to include photocatalysis on the reactor wall. The model was applied to a cylindrical reactor containing a 40 W amalgam UV lamp in the axis. The model predictions of photodegradation with 254 nm and 185 nm light irradiation was compared with a combination of photolytic and photocatalytic degradation. At air flow rates of 1 L/min and benzene mass flow rates ranging from 0.5 to 10 mg/min, a degradation efficiency of 77%-23% is predicted for the catalytic process. In comparison, the model of Mahmoudkhani (2012) predicted an efficiency of 95%-20% for the noncatalytic process. However, a maximum quantum yield (ϕ) of 6.67×〖10〗^(-4) was predicted for the photocatalytic process. This low value explains the lack of benefit predicted when a photocatalytic coating is applied. It is concluded that the photolytic approach is a feasible alternative to the photocatalytic approach, especially for low concentrations of benzene emissions from waste gas. Furthermore, adding ozone greatly improves the efficiency of the process. Modeling of photolytic degradation with ozone confirms the experimental results; however, the modeling slightly overestimates the efficiency. Based on energy requirement calculations, it is concluded that the lowest energy is consumed when combination of ozone premixing and condensation pretreatment along with UV photolysis is used.","abstract_has_math":false,"creators":["Atyabi, Mahsasadat"],"institution":"Graduate Studies","degree_name":"Master of Science (MSc)","degree_level":null,"degree_discipline":"Chemical and Petroleum Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["De Visscher, Alex"],"committee_chairs":[],"committee_members":[],"year":2013,"date_issued":"2013-01-31","date_published":"2013-01-31","updated_at":"2026-11-19T07:25:31Z","subjects":["Engineering--Environmental"],"languages":["eng"],"rights":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/11023/537"],"render_values":[{"text":"http://hdl.handle.net/11023/537","href":"https://hdl.handle.net/11023/537","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.11575/PRISM/28547","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.11575/PRISM/28547","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://ucalgary.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aucalgary.scholaris.ca%3A11023%2F537","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["De Visscher, Alex"]},{"key":"dc:creator","label":"Author","values":["Atyabi, Mahsasadat"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2013-01-31T21:19:01Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2013-06-15T07:01:48Z"]},{"key":"dc:date.issued","label":"Date","values":["2013-01-31"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["2013"]},{"key":"dc:publisher.faculty","label":"Dc Publisher Faculty","values":["Graduate Studies"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Calgary"]},{"key":"dc:publisher.place","label":"Dc Publisher Place","values":["Calgary"]},{"key":"dc:type","label":"Dc Type","values":["master thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Chemical and Petroleum Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MSc)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Calgary"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Engineering--Environmental"]},{"key":"dc:subject.classification","label":"Dc Subject Classification","values":["Photolysis, Photocatalysis, degradation, BTX, ozone premixing"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Atyabi, M. (2013). Ultraviolet Degradation of BTX in Waste Gas: Effects of Photocatalysis and Ozone Premixing (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca. doi:10.11575/PRISM/28547"]},{"key":"dc:identifier.doi","label":"DOI","values":["http://dx.doi.org/10.11575/PRISM/28547"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/11023/537"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"atmire:migration.oldid","label":"Atmire Migration Oldid","values":["729"]},{"key":"dc:description.abstract","label":"Abstract","values":["The focus of this study is on potential modifications of ultraviolet degradation of BTX (Benzene, Toluene and Xylene) in waste gas. A considerable amount of such pollutants is emitted from glycol dehydrators in the natural gas sector. ThePhotolytic technique has been recognized as a promising technique to control BTX emissions to theenvironment. In this work the effectiveness of other alternatives such as photocatalytic technology and photolysis in the presence of ozone are studied. A simulation model developed for benzene photolysis in waste gas by Mahmoudkhani (2012) was extended to include photocatalysis on the reactor wall. The model was applied to a cylindrical reactor containing a 40 W amalgam UV lamp in the axis. The model predictions of photodegradation with 254 nm and 185 nm light irradiation was compared with a combination of photolytic and photocatalytic degradation. At air flow rates of 1 L/min and benzene mass flow rates ranging from 0.5 to 10 mg/min, a degradation efficiency of 77%-23% is predicted for the catalytic process. In comparison, the model of Mahmoudkhani (2012) predicted an efficiency of 95%-20% for the noncatalytic process. However, a maximum quantum yield (ϕ) of 6.67×〖10〗^(-4) was predicted for the photocatalytic process. This low value explains the lack of benefit predicted when a photocatalytic coating is applied. It is concluded that the photolytic approach is a feasible alternative to the photocatalytic approach, especially for low concentrations of benzene emissions from waste gas. Furthermore, adding ozone greatly improves the efficiency of the process. Modeling of photolytic degradation with ozone confirms the experimental results; however, the modeling slightly overestimates the efficiency. Based on energy requirement calculations, it is concluded that the lowest energy is consumed when combination of ozone premixing and condensation pretreatment along with UV photolysis is used."]},{"key":"dc:title","label":"Title","values":["Ultraviolet Degradation of BTX in Waste Gas: Effects of Photocatalysis and Ozone Premixing"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:request.copy","label":"Local Request Copy","values":["true"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"atmire:migration.oldid":["729"],"dc:contributor.advisor":["De Visscher, Alex"],"dc:creator":["Atyabi, Mahsasadat"],"dc:date.accessioned":["2013-01-31T21:19:01Z"],"dc:date.available":["2013-06-15T07:01:48Z"],"dc:date.issued":["2013-01-31"],"dc:date.submitted":["2013"],"dc:description.abstract":["The focus of this study is on potential modifications of ultraviolet degradation of BTX (Benzene, Toluene and Xylene) in waste gas. A considerable amount of such pollutants is emitted from glycol dehydrators in the natural gas sector. ThePhotolytic technique has been recognized as a promising technique to control BTX emissions to theenvironment. In this work the effectiveness of other alternatives such as photocatalytic technology and photolysis in the presence of ozone are studied. A simulation model developed for benzene photolysis in waste gas by Mahmoudkhani (2012) was extended to include photocatalysis on the reactor wall. The model was applied to a cylindrical reactor containing a 40 W amalgam UV lamp in the axis. The model predictions of photodegradation with 254 nm and 185 nm light irradiation was compared with a combination of photolytic and photocatalytic degradation. At air flow rates of 1 L/min and benzene mass flow rates ranging from 0.5 to 10 mg/min, a degradation efficiency of 77%-23% is predicted for the catalytic process. In comparison, the model of Mahmoudkhani (2012) predicted an efficiency of 95%-20% for the noncatalytic process. However, a maximum quantum yield (ϕ) of 6.67×〖10〗^(-4) was predicted for the photocatalytic process. This low value explains the lack of benefit predicted when a photocatalytic coating is applied. It is concluded that the photolytic approach is a feasible alternative to the photocatalytic approach, especially for low concentrations of benzene emissions from waste gas. Furthermore, adding ozone greatly improves the efficiency of the process. Modeling of photolytic degradation with ozone confirms the experimental results; however, the modeling slightly overestimates the efficiency. Based on energy requirement calculations, it is concluded that the lowest energy is consumed when combination of ozone premixing and condensation pretreatment along with UV photolysis is used."],"dc:identifier.citation":["Atyabi, M. (2013). Ultraviolet Degradation of BTX in Waste Gas: Effects of Photocatalysis and Ozone Premixing (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca. doi:10.11575/PRISM/28547"],"dc:identifier.doi":["http://dx.doi.org/10.11575/PRISM/28547"],"dc:identifier.uri":["http://hdl.handle.net/11023/537"],"dc:language.iso":["eng"],"dc:publisher.faculty":["Graduate Studies"],"dc:publisher.institution":["University of Calgary"],"dc:publisher.place":["Calgary"],"dc:rights":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."],"dc:subject":["Engineering--Environmental"],"dc:subject.classification":["Photolysis, Photocatalysis, degradation, BTX, ozone premixing"],"dc:title":["Ultraviolet Degradation of BTX in Waste Gas: Effects of Photocatalysis and Ozone Premixing"],"dc:type":["master thesis"],"dspace:entity.type":["Publication"],"local:request.copy":["true"],"others:access_status":["open.access"],"thesis:degree_discipline":["Chemical and Petroleum Engineering"],"thesis:degree_name":["Master of Science (MSc)"],"thesis:institution_name":["University of Calgary"]},"updated_at":"2026-11-19T07:25:31Z"}