{"id":{"repo_id":"calgary","oai_identifier":"oai:ucalgary.scholaris.ca:11023/584"},"canonical_url":"https://search.ndltd.org/etd/calgary/oai:ucalgary.scholaris.ca:11023/584","repository":{"repo_id":"calgary","name":"University of Calgary","base_url":"https://ucalgary.scholaris.ca/server/oai/request"},"display":{"title":"A Millimeter-Wave Radar and Kinect Depth Camera for Non-Contact Respiratory Sensing","abstract":"Remote, non-contact respiratory sensing has gained interest in the past decade with the dawn of cheaper microwave integrated circuits and optical devices. The need for an inexpensive and portable respiratory monitor is in particular demand in a hospital setting as the respiratory rate provides early warning for cardiorespiratory arrest. This thesis explores the hypothesis that an inexpensive millimeter-wave (MMW) radar module can synergize with an infrared (IR) camera to provide a low-cost module for accurate, long-term measurement of respiratory rate. Both the IR camera system and the MMW radar technique are experimentally validated. Promising results are presented for the IR camera in which the respiratory rate is accurately measured for different scenarios. Measurements with the MMW radar indicate that more expensive and complex hardware are required to achieve adequate results.","abstract_html":"Remote, non-contact respiratory sensing has gained interest in the past decade with the dawn of cheaper microwave integrated circuits and optical devices. The need for an inexpensive and portable respiratory monitor is in particular demand in a hospital setting as the respiratory rate provides early warning for cardiorespiratory arrest. This thesis explores the hypothesis that an inexpensive millimeter-wave (MMW) radar module can synergize with an infrared (IR) camera to provide a low-cost module for accurate, long-term measurement of respiratory rate. Both the IR camera system and the MMW radar technique are experimentally validated. Promising results are presented for the IR camera in which the respiratory rate is accurately measured for different scenarios. Measurements with the MMW radar indicate that more expensive and complex hardware are required to achieve adequate results.","abstract_has_math":false,"creators":["Loblaw, Andrew"],"institution":"Graduate Studies","degree_name":"Master of Science (MSc)","degree_level":null,"degree_discipline":"Electrical and Computer Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Okoniewski, Michal","Nielsen, John"],"committee_chairs":[],"committee_members":[],"year":2013,"date_issued":"2013-04-04","date_published":"2013-04-04","updated_at":"2026-11-19T07:36:55Z","subjects":["Engineering--Biomedical","Engineering--Electronics and Electrical"],"languages":["eng"],"rights":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/11023/584"],"render_values":[{"text":"http://hdl.handle.net/11023/584","href":"https://hdl.handle.net/11023/584","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.11575/PRISM/24790","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.11575/PRISM/24790","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Acalgary%3Aoai%3Aucalgary.scholaris.ca%3A11023%2F584","prefix":"oai_dc"},"source_record":{"url":"https://ucalgary.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aucalgary.scholaris.ca%3A11023%2F584","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Okoniewski, Michal","Nielsen, John"]},{"key":"dc:creator","label":"Author","values":["Loblaw, Andrew"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2013-04-04T15:36:33Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2013-06-15T07:01:51Z"]},{"key":"dc:date.issued","label":"Date","values":["2013-04-04"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["2013"]},{"key":"dc:publisher.faculty","label":"Dc Publisher Faculty","values":["Graduate Studies"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Calgary"]},{"key":"dc:publisher.place","label":"Dc Publisher Place","values":["Calgary"]},{"key":"dc:type","label":"Dc Type","values":["master thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical and Computer Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MSc)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Calgary"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Engineering--Biomedical","Engineering--Electronics and Electrical"]},{"key":"dc:subject.classification","label":"Dc Subject Classification","values":["IR-Camera","MMW-Radar"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Loblaw, A. (2013). A Millimeter-Wave Radar and Kinect Depth Camera for Non-Contact Respiratory Sensing (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca. doi:10.11575/PRISM/24790"]},{"key":"dc:identifier.doi","label":"DOI","values":["http://dx.doi.org/10.11575/PRISM/24790"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/11023/584"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"atmire:migration.oldid","label":"Atmire Migration Oldid","values":["785"]},{"key":"dc:description.abstract","label":"Abstract","values":["Remote, non-contact respiratory sensing has gained interest in the past decade with the dawn of cheaper microwave integrated circuits and optical devices. The need for an inexpensive and portable respiratory monitor is in particular demand in a hospital setting as the respiratory rate provides early warning for cardiorespiratory arrest. This thesis explores the hypothesis that an inexpensive millimeter-wave (MMW) radar module can synergize with an infrared (IR) camera to provide a low-cost module for accurate, long-term measurement of respiratory rate. Both the IR camera system and the MMW radar technique are experimentally validated. Promising results are presented for the IR camera in which the respiratory rate is accurately measured for different scenarios. Measurements with the MMW radar indicate that more expensive and complex hardware are required to achieve adequate results."]},{"key":"dc:title","label":"Title","values":["A Millimeter-Wave Radar and Kinect Depth Camera for Non-Contact Respiratory Sensing"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:request.copy","label":"Local Request Copy","values":["true"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"atmire:migration.oldid":["785"],"dc:contributor.advisor":["Okoniewski, Michal","Nielsen, John"],"dc:creator":["Loblaw, Andrew"],"dc:date.accessioned":["2013-04-04T15:36:33Z"],"dc:date.available":["2013-06-15T07:01:51Z"],"dc:date.issued":["2013-04-04"],"dc:date.submitted":["2013"],"dc:description.abstract":["Remote, non-contact respiratory sensing has gained interest in the past decade with the dawn of cheaper microwave integrated circuits and optical devices. The need for an inexpensive and portable respiratory monitor is in particular demand in a hospital setting as the respiratory rate provides early warning for cardiorespiratory arrest. This thesis explores the hypothesis that an inexpensive millimeter-wave (MMW) radar module can synergize with an infrared (IR) camera to provide a low-cost module for accurate, long-term measurement of respiratory rate. Both the IR camera system and the MMW radar technique are experimentally validated. Promising results are presented for the IR camera in which the respiratory rate is accurately measured for different scenarios. Measurements with the MMW radar indicate that more expensive and complex hardware are required to achieve adequate results."],"dc:identifier.citation":["Loblaw, A. (2013). A Millimeter-Wave Radar and Kinect Depth Camera for Non-Contact Respiratory Sensing (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca. doi:10.11575/PRISM/24790"],"dc:identifier.doi":["http://dx.doi.org/10.11575/PRISM/24790"],"dc:identifier.uri":["http://hdl.handle.net/11023/584"],"dc:language.iso":["eng"],"dc:publisher.faculty":["Graduate Studies"],"dc:publisher.institution":["University of Calgary"],"dc:publisher.place":["Calgary"],"dc:rights":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."],"dc:subject":["Engineering--Biomedical","Engineering--Electronics and Electrical"],"dc:subject.classification":["IR-Camera","MMW-Radar"],"dc:title":["A Millimeter-Wave Radar and Kinect Depth Camera for Non-Contact Respiratory Sensing"],"dc:type":["master thesis"],"dspace:entity.type":["Publication"],"local:request.copy":["true"],"others:access_status":["open.access"],"thesis:degree_discipline":["Electrical and Computer Engineering"],"thesis:degree_name":["Master of Science (MSc)"],"thesis:institution_name":["University of Calgary"]},"updated_at":"2026-11-19T07:36:55Z"}