{"id":{"repo_id":"calgary","oai_identifier":"oai:ucalgary.scholaris.ca:11023/624"},"canonical_url":"https://search.ndltd.org/etd/calgary/oai:ucalgary.scholaris.ca:11023/624","repository":{"repo_id":"calgary","name":"University of Calgary","base_url":"https://ucalgary.scholaris.ca/server/oai/request"},"display":{"title":"Advances of Interfacial Property Determination Using X-Ray Micro Imaging","abstract":"The main objectives of this research project are to analyze the challenges X-ray micro imaging has to determine interfacial properties, propose a solution to be able to implement X-rays in the determination of contact angle and interfacial tension and establish the reliability and practicality of microtomography in the determination of interfacial properties. An extensive set of experiments has been executed using a legacy cell to analyze the challenges previous work faced. A new and improved cell to use in a micro CT-scanner has been designed and constructed which gave us an easier manner to set up the experiments in the micro CT scanner. New experiments were conducted using a proposed solution to these challenges and the results obtained have accuracy and reliability. Finally, the determination of contact angle and interfacial tension was conducted in water-wet, neutral and oil-based substrate systems at standard conditions. The limitations given by the micro CT-scanner were in a great manner resolved. Even though the procedure is tedious and time consuming it is accurate and reliable. This makes microtomography attractive to be used in the determination of interfacial properties. Further experimentation is recommended in the development of this new method under different conditions, especially reservoir conditions.","abstract_html":"The main objectives of this research project are to analyze the challenges X-ray micro imaging has to determine interfacial properties, propose a solution to be able to implement X-rays in the determination of contact angle and interfacial tension and establish the reliability and practicality of microtomography in the determination of interfacial properties. An extensive set of experiments has been executed using a legacy cell to analyze the challenges previous work faced. A new and improved cell to use in a micro CT-scanner has been designed and constructed which gave us an easier manner to set up the experiments in the micro CT scanner. New experiments were conducted using a proposed solution to these challenges and the results obtained have accuracy and reliability. Finally, the determination of contact angle and interfacial tension was conducted in water-wet, neutral and oil-based substrate systems at standard conditions. The limitations given by the micro CT-scanner were in a great manner resolved. Even though the procedure is tedious and time consuming it is accurate and reliable. This makes microtomography attractive to be used in the determination of interfacial properties. Further experimentation is recommended in the development of this new method under different conditions, especially reservoir conditions.","abstract_has_math":false,"creators":["Rodriguez Bermudez, Alonso"],"institution":"Graduate Studies","degree_name":"Master of Science (MSc)","degree_level":null,"degree_discipline":"Chemical and Petroleum Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Kantzas, Apostolos"],"committee_chairs":[],"committee_members":[],"year":2013,"date_issued":"2013-04-25","date_published":"2013-04-25","updated_at":"2026-11-19T07:30:12Z","subjects":["Engineering--Chemical","Engineering--Petroleum"],"languages":["eng"],"rights":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/11023/624"],"render_values":[{"text":"http://hdl.handle.net/11023/624","href":"https://hdl.handle.net/11023/624","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.11575/PRISM/24727","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.11575/PRISM/24727","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Acalgary%3Aoai%3Aucalgary.scholaris.ca%3A11023%2F624","prefix":"oai_dc"},"source_record":{"url":"https://ucalgary.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aucalgary.scholaris.ca%3A11023%2F624","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Kantzas, Apostolos"]},{"key":"dc:creator","label":"Author","values":["Rodriguez Bermudez, Alonso"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2013-04-25T15:40:40Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2013-06-10T07:00:45Z"]},{"key":"dc:date.issued","label":"Date","values":["2013-04-25"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["2013"]},{"key":"dc:publisher.faculty","label":"Dc Publisher Faculty","values":["Graduate Studies"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Calgary"]},{"key":"dc:publisher.place","label":"Dc Publisher Place","values":["Calgary"]},{"key":"dc:type","label":"Dc Type","values":["master thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Chemical and Petroleum Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MSc)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Calgary"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Engineering--Chemical","Engineering--Petroleum"]},{"key":"dc:subject.classification","label":"Dc Subject Classification","values":["microtomography","interfacial properties","contact angle"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Rodriguez Bermudez, A. (2013). Advances of Interfacial Property Determination Using X-Ray Micro Imaging (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca. doi:10.11575/PRISM/24727"]},{"key":"dc:identifier.doi","label":"DOI","values":["http://dx.doi.org/10.11575/PRISM/24727"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/11023/624"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"atmire:migration.oldid","label":"Atmire Migration Oldid","values":["828"]},{"key":"dc:description.abstract","label":"Abstract","values":["The main objectives of this research project are to analyze the challenges X-ray micro imaging has to determine interfacial properties, propose a solution to be able to implement X-rays in the determination of contact angle and interfacial tension and establish the reliability and practicality of microtomography in the determination of interfacial properties. An extensive set of experiments has been executed using a legacy cell to analyze the challenges previous work faced. A new and improved cell to use in a micro CT-scanner has been designed and constructed which gave us an easier manner to set up the experiments in the micro CT scanner. New experiments were conducted using a proposed solution to these challenges and the results obtained have accuracy and reliability. Finally, the determination of contact angle and interfacial tension was conducted in water-wet, neutral and oil-based substrate systems at standard conditions. The limitations given by the micro CT-scanner were in a great manner resolved. Even though the procedure is tedious and time consuming it is accurate and reliable. This makes microtomography attractive to be used in the determination of interfacial properties. Further experimentation is recommended in the development of this new method under different conditions, especially reservoir conditions."]},{"key":"dc:title","label":"Title","values":["Advances of Interfacial Property Determination Using X-Ray Micro Imaging"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:request.copy","label":"Local Request Copy","values":["true"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"atmire:migration.oldid":["828"],"dc:contributor.advisor":["Kantzas, Apostolos"],"dc:creator":["Rodriguez Bermudez, Alonso"],"dc:date.accessioned":["2013-04-25T15:40:40Z"],"dc:date.available":["2013-06-10T07:00:45Z"],"dc:date.issued":["2013-04-25"],"dc:date.submitted":["2013"],"dc:description.abstract":["The main objectives of this research project are to analyze the challenges X-ray micro imaging has to determine interfacial properties, propose a solution to be able to implement X-rays in the determination of contact angle and interfacial tension and establish the reliability and practicality of microtomography in the determination of interfacial properties. An extensive set of experiments has been executed using a legacy cell to analyze the challenges previous work faced. A new and improved cell to use in a micro CT-scanner has been designed and constructed which gave us an easier manner to set up the experiments in the micro CT scanner. New experiments were conducted using a proposed solution to these challenges and the results obtained have accuracy and reliability. Finally, the determination of contact angle and interfacial tension was conducted in water-wet, neutral and oil-based substrate systems at standard conditions. The limitations given by the micro CT-scanner were in a great manner resolved. Even though the procedure is tedious and time consuming it is accurate and reliable. This makes microtomography attractive to be used in the determination of interfacial properties. Further experimentation is recommended in the development of this new method under different conditions, especially reservoir conditions."],"dc:identifier.citation":["Rodriguez Bermudez, A. (2013). Advances of Interfacial Property Determination Using X-Ray Micro Imaging (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca. doi:10.11575/PRISM/24727"],"dc:identifier.doi":["http://dx.doi.org/10.11575/PRISM/24727"],"dc:identifier.uri":["http://hdl.handle.net/11023/624"],"dc:language.iso":["eng"],"dc:publisher.faculty":["Graduate Studies"],"dc:publisher.institution":["University of Calgary"],"dc:publisher.place":["Calgary"],"dc:rights":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."],"dc:subject":["Engineering--Chemical","Engineering--Petroleum"],"dc:subject.classification":["microtomography","interfacial properties","contact angle"],"dc:title":["Advances of Interfacial Property Determination Using X-Ray Micro Imaging"],"dc:type":["master thesis"],"dspace:entity.type":["Publication"],"local:request.copy":["true"],"others:access_status":["open.access"],"thesis:degree_discipline":["Chemical and Petroleum Engineering"],"thesis:degree_name":["Master of Science (MSc)"],"thesis:institution_name":["University of Calgary"]},"updated_at":"2026-11-19T07:30:12Z"}