{"id":{"repo_id":"calgary","oai_identifier":"oai:ucalgary.scholaris.ca:11023/709"},"canonical_url":"https://search.ndltd.org/etd/calgary/oai:ucalgary.scholaris.ca:11023/709","repository":{"repo_id":"calgary","name":"University of Calgary","base_url":"https://ucalgary.scholaris.ca/server/oai/request"},"display":{"title":"Determination of Low Molecular Weight Acids in Mist Chamber Extracts by Capillary Electrophoresis and Ion Chromatography","abstract":"Acidic gases are important trace components of the troposphere because they contribute to particle formation and acid deposition. Here, a mist chamber (MIST) was used to collect acidic gases into aqueous solutions, which were analyzed by ion chromatography (IC) or capillary electrophoresis (CE). A CE method was developed, in which anions were separated in either a didodecyldimethylammonium or dimethyldioctadecylammonium bromide modified capillary at pH 5.86 and detected by indirect UV absorbance using naphthalenedisulfonate as probe with detection limits of 10 to 20 µM. The MIST collection efficiency (COE) was determined by chemical ionization mass spectrometry using acetate reagent ion. For HCOOH, the COE was < 80% when deionized water was used as trapping solution. The mass spectrometer was calibrated by MIST – IC and was superior with respect to response time (1 s versus 10 min), detection limit (< 100 ppt versus ~6 ppb), and near-absence of inlet memory effects.","abstract_html":"Acidic gases are important trace components of the troposphere because they contribute to particle formation and acid deposition. Here, a mist chamber (MIST) was used to collect acidic gases into aqueous solutions, which were analyzed by ion chromatography (IC) or capillary electrophoresis (CE). A CE method was developed, in which anions were separated in either a didodecyldimethylammonium or dimethyldioctadecylammonium bromide modified capillary at pH 5.86 and detected by indirect UV absorbance using naphthalenedisulfonate as probe with detection limits of 10 to 20 µM. The MIST collection efficiency (COE) was determined by chemical ionization mass spectrometry using acetate reagent ion. For HCOOH, the COE was &lt; 80% when deionized water was used as trapping solution. The mass spectrometer was calibrated by MIST – IC and was superior with respect to response time (1 s versus 10 min), detection limit (&lt; 100 ppt versus ~6 ppb), and near-absence of inlet memory effects.","abstract_has_math":false,"creators":["Zhou, Xueting"],"institution":"Graduate Studies","degree_name":"Master of Science (MSc)","degree_level":null,"degree_discipline":"Chemistry","degree_department":null,"school":null,"contributors":[],"advisors":["Osthoff, Hans"],"committee_chairs":[],"committee_members":[],"year":2013,"date_issued":"2013-05-10","date_published":"2013-05-10","updated_at":"2026-11-19T07:28:50Z","subjects":["Atmospheric Sciences","Environmental Sciences","Chemistry--Analytical"],"languages":["eng"],"rights":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/11023/709"],"render_values":[{"text":"http://hdl.handle.net/11023/709","href":"https://hdl.handle.net/11023/709","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.11575/PRISM/25605","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.11575/PRISM/25605","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://ucalgary.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aucalgary.scholaris.ca%3A11023%2F709","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Osthoff, Hans"]},{"key":"dc:creator","label":"Author","values":["Zhou, Xueting"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2013-05-10T17:38:06Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2013-11-12T08:00:13Z"]},{"key":"dc:date.issued","label":"Date","values":["2013-05-10"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["2013"]},{"key":"dc:publisher.faculty","label":"Dc Publisher Faculty","values":["Graduate Studies"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Calgary"]},{"key":"dc:publisher.place","label":"Dc Publisher Place","values":["Calgary"]},{"key":"dc:type","label":"Dc Type","values":["master thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Chemistry"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MSc)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Calgary"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Atmospheric Sciences","Environmental Sciences","Chemistry--Analytical"]},{"key":"dc:subject.classification","label":"Dc Subject Classification","values":["capillary electrophoresis","low molecular weight acids","mist chamber","Mass spectrometry"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Zhou, X. (2013). Determination of Low Molecular Weight Acids in Mist Chamber Extracts by Capillary Electrophoresis and Ion Chromatography (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca. doi:10.11575/PRISM/25605"]},{"key":"dc:identifier.doi","label":"DOI","values":["http://dx.doi.org/10.11575/PRISM/25605"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/11023/709"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"atmire:migration.oldid","label":"Atmire Migration Oldid","values":["987"]},{"key":"dc:description.abstract","label":"Abstract","values":["Acidic gases are important trace components of the troposphere because they contribute to particle formation and acid deposition. Here, a mist chamber (MIST) was used to collect acidic gases into aqueous solutions, which were analyzed by ion chromatography (IC) or capillary electrophoresis (CE). A CE method was developed, in which anions were separated in either a didodecyldimethylammonium or dimethyldioctadecylammonium bromide modified capillary at pH 5.86 and detected by indirect UV absorbance using naphthalenedisulfonate as probe with detection limits of 10 to 20 µM. The MIST collection efficiency (COE) was determined by chemical ionization mass spectrometry using acetate reagent ion. For HCOOH, the COE was < 80% when deionized water was used as trapping solution. The mass spectrometer was calibrated by MIST – IC and was superior with respect to response time (1 s versus 10 min), detection limit (< 100 ppt versus ~6 ppb), and near-absence of inlet memory effects."]},{"key":"dc:title","label":"Title","values":["Determination of Low Molecular Weight Acids in Mist Chamber Extracts by Capillary Electrophoresis and Ion Chromatography"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:request.copy","label":"Local Request Copy","values":["true"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"atmire:migration.oldid":["987"],"dc:contributor.advisor":["Osthoff, Hans"],"dc:creator":["Zhou, Xueting"],"dc:date.accessioned":["2013-05-10T17:38:06Z"],"dc:date.available":["2013-11-12T08:00:13Z"],"dc:date.issued":["2013-05-10"],"dc:date.submitted":["2013"],"dc:description.abstract":["Acidic gases are important trace components of the troposphere because they contribute to particle formation and acid deposition. Here, a mist chamber (MIST) was used to collect acidic gases into aqueous solutions, which were analyzed by ion chromatography (IC) or capillary electrophoresis (CE). A CE method was developed, in which anions were separated in either a didodecyldimethylammonium or dimethyldioctadecylammonium bromide modified capillary at pH 5.86 and detected by indirect UV absorbance using naphthalenedisulfonate as probe with detection limits of 10 to 20 µM. The MIST collection efficiency (COE) was determined by chemical ionization mass spectrometry using acetate reagent ion. For HCOOH, the COE was < 80% when deionized water was used as trapping solution. The mass spectrometer was calibrated by MIST – IC and was superior with respect to response time (1 s versus 10 min), detection limit (< 100 ppt versus ~6 ppb), and near-absence of inlet memory effects."],"dc:identifier.citation":["Zhou, X. (2013). Determination of Low Molecular Weight Acids in Mist Chamber Extracts by Capillary Electrophoresis and Ion Chromatography (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca. doi:10.11575/PRISM/25605"],"dc:identifier.doi":["http://dx.doi.org/10.11575/PRISM/25605"],"dc:identifier.uri":["http://hdl.handle.net/11023/709"],"dc:language.iso":["eng"],"dc:publisher.faculty":["Graduate Studies"],"dc:publisher.institution":["University of Calgary"],"dc:publisher.place":["Calgary"],"dc:rights":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."],"dc:subject":["Atmospheric Sciences","Environmental Sciences","Chemistry--Analytical"],"dc:subject.classification":["capillary electrophoresis","low molecular weight acids","mist chamber","Mass spectrometry"],"dc:title":["Determination of Low Molecular Weight Acids in Mist Chamber Extracts by Capillary Electrophoresis and Ion Chromatography"],"dc:type":["master thesis"],"dspace:entity.type":["Publication"],"local:request.copy":["true"],"others:access_status":["open.access"],"thesis:degree_discipline":["Chemistry"],"thesis:degree_name":["Master of Science (MSc)"],"thesis:institution_name":["University of Calgary"]},"updated_at":"2026-11-19T07:28:50Z"}