{"id":{"repo_id":"calgary","oai_identifier":"oai:ucalgary.scholaris.ca:11023/958"},"canonical_url":"https://search.ndltd.org/etd/calgary/oai:ucalgary.scholaris.ca:11023/958","repository":{"repo_id":"calgary","name":"University of Calgary","base_url":"https://ucalgary.scholaris.ca/server/oai/request"},"display":{"title":"Treatment of SAGD water using low coagulant dose and Fenton oxidation","abstract":"The use of coagulation and Fenton oxidation was studied for total organic carbon (TOC) and silica removal from SAGD water at 80oC and 22oC and two different concentrations replicating the stream feeding the warm lime softening unit and the blowdown of the once through steam generator (OTSG). Coagulation was carried out by the addition of FeCl3, Al(NO3)3 and Ca(NO3)2. The results showed that Fe(III) salt outperformed Al(III) and Ca(II) salts. A two-stage addition of 2.5 g FeCl3 per g TOC intermediated by a filtration unit resulted in approximately 72% TOC removal and more than 80% Si removal while maintaining low solid waste. It is believed that silica removal was governed by the resultant pH, whereas TOC removal was accomplished through localized enmeshment coagulation. Fenton Oxidation is proposed to further treat the filtrate obtained from the second stage Fe(III) coagulation. An additional 10% TOC removal could be achieved at 7 times lower H2O2 dose in the presence of Fe2+ or Fe0 reagent. Moreover, Advanced Fenton Process resulted in high Si removal as a consequence of adsorption onto Fe(OH)3 precipitate, which formed at the natural equilibrium pH of the system.","abstract_html":"The use of coagulation and Fenton oxidation was studied for total organic carbon (TOC) and silica removal from SAGD water at 80oC and 22oC and two different concentrations replicating the stream feeding the warm lime softening unit and the blowdown of the once through steam generator (OTSG). Coagulation was carried out by the addition of FeCl3, Al(NO3)3 and Ca(NO3)2. The results showed that Fe(III) salt outperformed Al(III) and Ca(II) salts. A two-stage addition of 2.5 g FeCl3 per g TOC intermediated by a filtration unit resulted in approximately 72% TOC removal and more than 80% Si removal while maintaining low solid waste. It is believed that silica removal was governed by the resultant pH, whereas TOC removal was accomplished through localized enmeshment coagulation. Fenton Oxidation is proposed to further treat the filtrate obtained from the second stage Fe(III) coagulation. An additional 10% TOC removal could be achieved at 7 times lower H2O2 dose in the presence of Fe2+ or Fe0 reagent. Moreover, Advanced Fenton Process resulted in high Si removal as a consequence of adsorption onto Fe(OH)3 precipitate, which formed at the natural equilibrium pH of the system.","abstract_has_math":false,"creators":["Al-As'ad, Ahmad"],"institution":"Graduate Studies","degree_name":"Master of Science (MSc)","degree_level":null,"degree_discipline":"Chemical and Petroleum Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Husein, Maen"],"committee_chairs":[],"committee_members":[],"year":2013,"date_issued":"2013-09-13","date_published":"2013-09-13","updated_at":"2026-11-19T07:29:18Z","subjects":["Chemical","Environmental"],"languages":["eng"],"rights":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/11023/958"],"render_values":[{"text":"http://hdl.handle.net/11023/958","href":"https://hdl.handle.net/11023/958","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.11575/PRISM/28524","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.11575/PRISM/28524","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Acalgary%3Aoai%3Aucalgary.scholaris.ca%3A11023%2F958","prefix":"oai_dc"},"source_record":{"url":"https://ucalgary.scholaris.ca/server/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Aucalgary.scholaris.ca%3A11023%2F958","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Husein, Maen"]},{"key":"dc:creator","label":"Author","values":["Al-As'ad, Ahmad"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2013-09-13T18:45:55Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2013-11-12T08:00:11Z"]},{"key":"dc:date.issued","label":"Date","values":["2013-09-13"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["2013"]},{"key":"dc:publisher.faculty","label":"Dc Publisher Faculty","values":["Graduate Studies"]},{"key":"dc:publisher.institution","label":"Dc Publisher Institution","values":["University of Calgary"]},{"key":"dc:publisher.place","label":"Dc Publisher Place","values":["Calgary"]},{"key":"dc:type","label":"Dc Type","values":["master thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Chemical and Petroleum Engineering"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science (MSc)"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["University of Calgary"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Chemical","Environmental"]},{"key":"dc:subject.classification","label":"Dc Subject Classification","values":["SAGD","Water Treatment","Fenton","Coagulation","TOC","Silica"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["eng"]},{"key":"dc:rights","label":"Dc Rights","values":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.citation","label":"Dc Identifier Citation","values":["Al-As'ad, A. (2013). Treatment of SAGD water using low coagulant dose and Fenton oxidation (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca. doi:10.11575/PRISM/28524"]},{"key":"dc:identifier.doi","label":"DOI","values":["http://dx.doi.org/10.11575/PRISM/28524"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/11023/958"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"atmire:migration.oldid","label":"Atmire Migration Oldid","values":["1332"]},{"key":"dc:description.abstract","label":"Abstract","values":["The use of coagulation and Fenton oxidation was studied for total organic carbon (TOC) and silica removal from SAGD water at 80oC and 22oC and two different concentrations replicating the stream feeding the warm lime softening unit and the blowdown of the once through steam generator (OTSG). Coagulation was carried out by the addition of FeCl3, Al(NO3)3 and Ca(NO3)2. The results showed that Fe(III) salt outperformed Al(III) and Ca(II) salts. A two-stage addition of 2.5 g FeCl3 per g TOC intermediated by a filtration unit resulted in approximately 72% TOC removal and more than 80% Si removal while maintaining low solid waste. It is believed that silica removal was governed by the resultant pH, whereas TOC removal was accomplished through localized enmeshment coagulation. Fenton Oxidation is proposed to further treat the filtrate obtained from the second stage Fe(III) coagulation. An additional 10% TOC removal could be achieved at 7 times lower H2O2 dose in the presence of Fe2+ or Fe0 reagent. Moreover, Advanced Fenton Process resulted in high Si removal as a consequence of adsorption onto Fe(OH)3 precipitate, which formed at the natural equilibrium pH of the system."]},{"key":"dc:title","label":"Title","values":["Treatment of SAGD water using low coagulant dose and Fenton oxidation"]},{"key":"dspace:entity.type","label":"Dspace Entity Type","values":["Publication"]},{"key":"local:request.copy","label":"Local Request Copy","values":["true"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"atmire:migration.oldid":["1332"],"dc:contributor.advisor":["Husein, Maen"],"dc:creator":["Al-As'ad, Ahmad"],"dc:date.accessioned":["2013-09-13T18:45:55Z"],"dc:date.available":["2013-11-12T08:00:11Z"],"dc:date.issued":["2013-09-13"],"dc:date.submitted":["2013"],"dc:description.abstract":["The use of coagulation and Fenton oxidation was studied for total organic carbon (TOC) and silica removal from SAGD water at 80oC and 22oC and two different concentrations replicating the stream feeding the warm lime softening unit and the blowdown of the once through steam generator (OTSG). Coagulation was carried out by the addition of FeCl3, Al(NO3)3 and Ca(NO3)2. The results showed that Fe(III) salt outperformed Al(III) and Ca(II) salts. A two-stage addition of 2.5 g FeCl3 per g TOC intermediated by a filtration unit resulted in approximately 72% TOC removal and more than 80% Si removal while maintaining low solid waste. It is believed that silica removal was governed by the resultant pH, whereas TOC removal was accomplished through localized enmeshment coagulation. Fenton Oxidation is proposed to further treat the filtrate obtained from the second stage Fe(III) coagulation. An additional 10% TOC removal could be achieved at 7 times lower H2O2 dose in the presence of Fe2+ or Fe0 reagent. Moreover, Advanced Fenton Process resulted in high Si removal as a consequence of adsorption onto Fe(OH)3 precipitate, which formed at the natural equilibrium pH of the system."],"dc:identifier.citation":["Al-As'ad, A. (2013). Treatment of SAGD water using low coagulant dose and Fenton oxidation (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca. doi:10.11575/PRISM/28524"],"dc:identifier.doi":["http://dx.doi.org/10.11575/PRISM/28524"],"dc:identifier.uri":["http://hdl.handle.net/11023/958"],"dc:language.iso":["eng"],"dc:publisher.faculty":["Graduate Studies"],"dc:publisher.institution":["University of Calgary"],"dc:publisher.place":["Calgary"],"dc:rights":["University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission."],"dc:subject":["Chemical","Environmental"],"dc:subject.classification":["SAGD","Water Treatment","Fenton","Coagulation","TOC","Silica"],"dc:title":["Treatment of SAGD water using low coagulant dose and Fenton oxidation"],"dc:type":["master thesis"],"dspace:entity.type":["Publication"],"local:request.copy":["true"],"others:access_status":["open.access"],"thesis:degree_discipline":["Chemical and Petroleum Engineering"],"thesis:degree_name":["Master of Science (MSc)"],"thesis:institution_name":["University of Calgary"]},"updated_at":"2026-11-19T07:29:18Z"}